§ 400.250 — Pipeline Setbacks
Code of Ordinances, City of O'Fallon, Missouri (Code 2026-10-22) · O'Fallon City Code § 400.250
Corpus is an independent public-information project, not the official City of O'Fallon website. Stable reference: corpuslaw.us/code/1939a644-3a52-4c30-b2a6-bec4e42f485e
Section 400.250: Pipeline Setbacks.
A. A use requiring evacuation assistance is prohibited in a structure intended for human occupancy that is located within five hundred (500) feet of a hazardous pipeline. This prohibition does not apply to a structure that is located at least two hundred (200) feet from a hazardous pipeline if, by resolution, the City Council determines, after receiving a recommendation from the Building Official, that: 1. The structure has a performance-based design that provides an adequate time period for occupant evacuation to a safe place in the event of a hazardous pipeline leak or fire association with a hazardous pipeline, after considering: a. The requirements of the 2000 Edition of the National Fire Protection Association 101 Life Safety Code; b. The site and structure design; c. The structure's building materials; d. The structure's distance from the pipeline; e. The use of radiant energy barriers; f. Access to the site and the structure by emergency providers; g. Available on-site resources for emergency responders; h. The topography and other natural features; i. The use of the structure; j. The evacuation capability of the occupants. 2. The structure incorporates a system for the early detection and notification of a pipeline leak if the Building Official determines that an appropriate system is commercially available; and 3. The performance-based design for occupant evacuation and the early detection and notification system are certified and sealed by an engineer registered in the State of Missouri. B. Except as otherwise set forth in this Section, a person may not build new construction within any restricted pipeline area or within any limited improvement area. Notwithstanding anything in this Section to the contrary, fences, signage, decks, sun porches, screen porches, patios, swimming pools, sheds, landscaping, detached garages, mechanical units, trash enclosures, and lighting are permitted in a limited improvement area. C. A person may not place a structure or excavate within a restricted pipeline area. 1. This prohibition does not apply to: a. The hazardous pipeline or an appurtenance to the pipeline; b. A facility that produces, consumes, processes or stores the product transported by the hazardous pipeline, including a power generation facility; c. A utility line that crosses the restricted pipeline area, including an appurtenance to the line; d. A utility service connection; e. A road; f. A surface parking lot; g. A structure or excavation that the Building Official determines does not disturb the pipeline or impede its operation; h. Grading that the Building Official determines does not disturb the pipeline or impede its operation. 2. Before a person may place a road, surface parking lot or utility line in a restricted pipeline area, the person must deliver to the Building Official a certification by an engineer registered in the State of Missouri stating that the proposed construction activity and structure are designed to prevent disturbing the hazardous pipeline or impeding its operation. D. In calculating minimum lot area under this Chapter, a restricted pipeline area is excluded.
[ Ord. No. 7042 , 8-24-2023 ]
Ask a question about O'Fallon law
Corpus searches the O'Fallon sections it holds and shows the ones that match, with their citations. Free, no sign-in.
