For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 400.260 — Yard And Setback Exceptions

Code of Ordinances, City of O'Fallon, Missouri (Code 2026-10-22) · O'Fallon City Code § 400.260

Corpus is an independent public-information project, not the official City of O'Fallon website. Stable reference: corpuslaw.us/code/dd591d56-d377-477f-b04a-4ebf254c183f

Section 400.260: Yard And Setback Exceptions.

A. Commercial/Industrial Front Yards. In Districts "C-1," "C-2," "C-3," "I-1," and "I-2" where buildings located in the same block on the same side of a street have provided front yards of greater depth than herein required, the Planning and Zoning Commission may require a similar setback for buildings or structures constructed thereafter. B. Determination Of Setbacks. In measuring a yard, the minimum horizontal distance between the proposed right-of-way line and the main building shall be used. The required setback line shall be measured from the proposed right-of-way line. C. Structural Projections. Every part of a required yard shall be open from its lowest point to the sky unobstructed. Exceptions: 1. The ordinary projection of sills, belt courses, chimneys, cornices, buttresses, ornamental features, bay windows, and eaves; provided, however, that none of the above projections shall extend into a minimum yard more than twenty-six (26) inches; and provided, further, that projections are not into an easement. Chimneys are allowed to cantilever into an easement as follows: a. Chimney shall not extend into a side yard easement when a water or sewer (sanitary or storm) main is present. If a water or sewer main is not present, chimneys may extend into the required side yard over the easement up to twenty-six (26) inches, provided it does not extend closer that three (3) feet from the property line. b. On any building permit application submitted that a chimney is shown to extend into the side yard easement, the applicant's engineer or surveyor shall note that water or sewer mains are not located in said easement. 2. Balconies, canopies, or open porches having an area not exceeding sixty (60) square feet may project a maximum of six (6) feet into the required front or rear yard, and existing open porches extending into the required yard shall not be enclosed. 3. Mechanical units such as air-conditioner condensers, generators, and similar equipment are specifically excluded, whether attached or detached. Pool equipment shall not be considered a mechanical unit. D. Fire Escapes/Balconies. An open fire escape may project into a require side yard not more than one-half (1/2) the width of such yard, but not more than four (4) feet from the building. Fire escapes, solid-floored balconies, and enclosed outside stairways may project not more than four (4) feet into a required rear yard. E. Accessory Buildings And Structures. (See Section 400.275, Accessory Buildings and Structures). F. Sight Triangle And Obstruction. On the point of any access onto a public street or the intersection of any two (2) streets, development shall conform to the requirements of the sight triangle in which nothing shall be erected, placed, planted, or allowed to grow in such a manner as to materially impede vision between a height of thirty-six (36) inches and fifteen (15) feet above grade above the grades at the back of the curb of the intersecting streets, within the triangular area formed by the right-of-way lines and a line connecting them at points twenty-five (25) feet from their point of intersection or at equivalent points on private streets or as otherwise shown on the approved site plan. [image] G. Commercial/Industrial Rear Yards. No rear yard shall be required in Districts "C-1" to "I-2" inclusive on any lot used for business or industrial purposes, the rear line of which adjoins a railway right-of-way or, which has a rear railway right-of-way or which has a rear railway track connection. H. Through Lots. A through lot having one (1) end abutting a limited access highway, with no access permitted to that lot from said highway, shall be deemed to front upon the street which gives access to that lot. I. Residential Rear Yards. Nothing in these regulations shall preclude the Administrative Officer from granting an exception of the Zoning Code to allow a rear yard setback reduction to fifteen (15) for the purpose of constructing a covered patio/deck in the residential zoning districts of "R-1," "R-1A," "R-2," "R-3," "R-4," and "PUD." For the purposes of this Section, an "exception" is defined as "a relatively small departure of the Zoning Code that maintains the general intent and purpose of the Zoning Code." Such an exception cannot exceed an overall square footage encroachment of two hundred (200) square feet and shall apply only to a covered patio/deck. For the purposes of this Section, a "covered patio/deck" is defined as "a one (1) story structure either attached or detached from the principal structure. The cover shall only be enclosed by the principal structure. Structures enclosed with insect screening will only be allowed when no extension walls are constructed, excepting guardrails." 1. In the granting of an exception of the residential rear yard setback, the Administrative will notify all abutting lot owners to the residential property being considered for the exception. The applicant shall provide such information as may be requested by the Administrative Officer. The Administrative Officer shall review the information and can grant an exception on the basis that the spirit of these regulations shall be observed, safety and welfare secured, and substantial justice done. 2. Uncovered decks may encroach into the required rear yard, but shall be located at least ten (10) feet from the rear property line.

[ Ord. No. 7042 , 8-24-2023 ]

Ask a question about O'Fallon law

Corpus searches the O'Fallon sections it holds and shows the ones that match, with their citations. Free, no sign-in.