§ 29-193 — Monitoring facilities
Code of Ordinances of the City of St. Joseph, Missouri (Codified through Ordinance No. 3140, enacted February 2, 2026. (Supp. No. 8)) · St. Joseph Code of Ordinances § 29-193
Corpus is an independent public-information project, not the official City of St. Joseph website. Stable reference: corpuslaw.us/code/4f8e1c56-21af-4b33-ad08-c1a211580dc0
Sec. 29-193. - Monitoring facilities.
(a) When deemed necessary by the director, the owner of any property served by a building sewer carrying commercial or industrial wastes, other than domestic waste, shall install and shall maintain at his own expense a suitable sampling structure as approved by the director, upon each and every building sewer or shall combine the building sewers into a common building sewer upon which one sampling station shall be placed. The sampling structure shall be furnished with such necessary meters and other appurtenances in the building sewer to facilitate observation, sampling and measurement of the waters. Such structure shall be easily accessible and safely located and shall be constructed in accordance with plans approved by the director and shall be located so as to permit the gauging of flow and the collection of 24-hour composite samples truly representing the wastes leaving the property. Construction shall be completed within 90 calendar days following written notification by the city. (b) All measurements, tests and analyses of the characteristics of wastes shall be determined in accordance with 40 CFR 136, or other methods approved by the administrator, and sampling shall be carried out by customarily accepted methods to reflect the true characteristics of wastes. (c) All the characteristics of the wastes shall be obtained from 24-hour composite samples whereas temperatures, pH, cyanide, phenols, oil and grease, sulfide and volatile organics are determined from periodic grab samples. (d) The director or his representative shall be permitted access to the property at any time for the purpose of inspection, observation, measurement, sampling or testing. (e) Samples should be taken immediately downstream from pretreatment facilities if such exist or immediately downstream from the regulated process if no pretreatment exists. If other wastewaters are mixed with the regulated wastewater prior to pretreatment, the user should measure the flow and concentrations necessary to allow use of the combined wastestream formula to evaluate compliance with the pretreatment standards set forth in this article.
(Gen. Ord. No. 1007, § 1(23-78(d)), 8-17-92; G.O. 1742, 1-10-00)
Ask a question about St. Joseph law
Corpus searches the St. Joseph sections it holds and shows the ones that match, with their citations. Free, no sign-in.