Sec. 31-355. - General standards for wind energy facilities.
(a) Except as noted, the following requirements shall be applicable to all wind energy facilities installed, built or modified after the effective date of this article to the full extent permitted by law unless otherwise provided pursuant to Section 31-354 within the conditions of a planned unit development district: (1) Principal or accessory use. A wind energy facility may be either a principal use or an accessory use, subject to any applicable district requirement relating to yard area or setback, provided that no more than one small wind energy facility shall be located on a parcel and no more than three exempt facilities shall be permitted per parcel. (2) Building codes, safety standards, and zoning compliance. Wind energy facilities shall be constructed and maintained in compliance with all standards contained in applicable state and local building codes. In addition to any other approvals required by this section, no Wind energy facility shall be erected prior to receipt of an approved zoning certificate and the issuance of a building permit. (3) Regulatory compliance. All wind energy facilities shall meet or exceed current standards and regulations of the FAA, and any other state or federal agency with the authority to regulate applicable wind energy facilities. Should such standards or regulations be amended, then the owner shall bring such devices and structure into compliance with the revised standards or regulations within the time period mandated by the controlling agency. No approval for any placement, construction or modification of any wind energy facility permitted by this section shall be granted for any applicant having an uncured violation of this section or any other governmental regulatory requirement related to the subject property. (4) Security. All wind energy facilities shall be protected from unauthorized access by appropriate security measures. A description of proposed security measures shall be provided as part of any administrative or planned use application. Additional measures may be required as a condition of the issuance of a building permit or administrative permit as deemed necessary by the director or by the planning commission in the case of a planned use. (5) Lighting. Wind energy facilities shall not be lighted unless required by the FAA or other state or federal agency with authority to regulate, in which case a description of the required lighting scheme will be made a part of the application to install, build or modify the facility. Equipment cabinets and shelters, if permitted, may have lighting only as approved by the director on the approved site development plan. The requirement by the FAA or other agency for lighting of any proposed structure may be considered as a reasonable basis for denial of an application in any residential area or otherwise where incompatible with the surrounding uses. (6) Advertising. The placement of advertising on structures regulated by this section is prohibited, provided that a manufacturer or specification notice of less than one square foot in size shall be permitted. (7) Design. The design criteria for wind energy facilities shall be as follows: a. The support structure of any wind energy facility shall be of a monopole design and lattice towers are not permitted except that a lattice structure and rotors that replicate a historical windmill appearance may be approved. Guy wires are not permitted. b. Subject to the requirements of the FAA or any applicable state or federal agency, all visible portions of the wind energy facility shall be painted a non-reflective gray or other approved neutral color consistent with the natural or built environment of the site. Unpainted galvanized exposed material is prohibited. c. No equipment shelters or other accessory structures shall be permitted in conjunction with a wind energy facility except where underground, contained within an existing building, or otherwise appropriately concealed. d. All utilities serving the facility shall be underground. e. Design elements shall be of a type consistent with the zoning district and accessory uses of the property and adjoining area. (8) Height. A wind energy facility shall not be subject to building height restrictions within the applicable underlying zoning district but shall not exceed a height which is the lesser of: a. Thirty feet above the principal building height permitted within the zoning district, or b. The limitation set by any airport overlay zone as may be adopted by the city, FAA limitation, or other height restrictions established by the city, or c. A maximum of 75 feet. (9) Minimum ground clearance. The blade tip of any rotor, or other rotating portion of any non-exempt facility, shall have a clearance of not less than 25 feet at its closest point to the ground. (10) Setbacks. a. Wind energy facilities shall be separated from the property line of any adjacent property zoned or used for a residential use at least a distance equal to twice its height, and shall be separated from all other adjacent property lines at least a distance equal to its height. Set back distances shall be measured from the tip of the closest rotor blade at the point at which it is horizontal to and facing the applicable property line. b. Wind energy facilities shall be separated from public roads by a distance equal to its height. c. Wind energy facilities shall not be located in any front yard or front yard setback of any property. (11) Noise limitations. Noise emanating from the operation of a wind energy facility shall not exceed, at any time, the lowest ambient sound level that is present between the hours of 9:00 p.m. and 9:00 a.m. at any property line of a property used or zoned for residential use or used for a school, hospital, or place of worship. Noise emanating from the operation of a wind energy facility shall in no event exceed, at any time, 45 dBa measured at the property line. (12) Site improvements/screening. a. All support structures for wind energy facilities shall maintain a landscape strip of not less than ten feet in width and planted with materials which will provide a visual barrier to a minimum height of six feet if necessary to conceal any ground equipment, or safety walls or fences. The landscape strip shall be exterior to any security wall, if any. In lieu of the landscape strip, alternative screening may be approved or waived as part of the approval of any wind energy facility, upon demonstration by the applicant that an equivalent degree of visual screening will be achieved or is unnecessary. b. Vehicle or outdoor storage at any wind energy location is prohibited, unless otherwise permitted by the zoning applicable to other uses on the property. c. Access for periodic maintenance and service shall be provided consistent with the underlying zoning district. (13) Safety requirements. All wind energy facilities shall: a. Comply with the requirements of the Net Metering and Easy Connection Act, RSMo 386.890 (2008), to the extent such facility is connected to the retail electric supplier for net metering; b. Provide appropriate design or protection from ice falling hazards; c. Be unclimbable by design or protected by anti-climbing devices such as: i. Approved walls or fences with locking portals at least six feet high and having required landscape screening, or ii. Anti-climbing devices 12 feet vertical from the base of the WECS (wind energy conversion system) tower. d. Include power outage protection so as to automatically terminate power generation during any power outage in any electrical utility system being served. Certification or documentation of such design shall be included with any permit approval.
(G.O. 2363, 11-30-09)
Ask a question about St. Joseph law
Corpus searches the St. Joseph sections it holds and shows the ones that match, with their citations. Free, no sign-in.