309. Water Distribution System

309.1 All water systems shall be designed, constructed, inspected and tested in accordance with the applicable and current Ten State Standards (Recommended Standards for Water Works) by the Great Lakes, Upper Mississippi River Board of Public Health and Environmental Managers, except for more stringent requirements set forth by the appropriate Mississippi State authorities. 309.2 The developer shall connect the proposed subdivision to the D'Iberville Water Supply System. The developer will be responsible for any improvements required so that the existing water system can accommodate the increased demand placed upon it due to the new subdivision. 309.2.1 “W” shall be stamped into curbs at each water service location. “W” Water designation markers shall be cast into the curbs to provide a flush finish. Markers shall be placed at each service & valve location. Markers shall be constructed of cast aluminum. Color shall be Blue and resist weathering & fading. 309.2.2 Locate-wire and plastic warning tape shall be installed above all water mains and services 309.2.3 A water service shall be provided to all green areas common landscape areas. These areas receiving service will require metering, with the responsibility for payment placed on the developer or HOA. All lift stations will also require water service. 309.2.4 Water service lines shall not be located underneath the driveway access of a lot. 309.3 The subdivision's water distribution system shall be designed to maintain a minimum static pressure of forty (40) psi and a minimum dynamic pressure of twenty (20) psi with a minimum fire flow rate of one thousand (1000) gallons per minute in residentially zoned developments and a minimum fire flow rate of one thousand (1000) gallons per minute in commercially or industrially zoned developments. 309.4 Pipe sizes - All water mains should be designed based on hydraulic analysis using an appropriate friction coefficient to obtain the above pressure and flow rate requirement and shall meet or exceed the following: 309.4.1 The maximum Hazen-Williams C value to be used is 120. 309.4.2 The minimum main size should be six (6) inches regardless of the results of the hydraulic analysis, except for short dead-end lines less than four hundred (400) feet. 309.4.3 The use of less than four (4) inch lines is discouraged since they do not provide adequate capacity for enlargement or extension. 309.4.4 The minimum main size supplying fire hydrants should be as determined by hydraulic analysis using fire flows, but not less than eight (8) inches. 309.5 Materials - All materials used shall be non-toxic and approved for use in potable water systems by AWWA, USEPA, Underwriters Laboratory, National Sanitation Foundation, or other appropriate organization. 309.5.1 Cast iron, ductile iron, and steel pipes and fittings shall comply with the latest applicable standards issued by the American Water Works Association. 309.5.2 PVC pipe shall be C900 Class 150, DR 18 and bear the National Sanitation Foundation seal for Potable water and meet the requirements of ASTM D 1784 for Class 12454A or 13454 B compounds. The pipe shall meet the latest revision of the applicable AWWA or Commercial Standards. 309.5.3 All ductile iron pipe shall meet AWWA specification C-104 or C-11O, C-150 and C-151 for appropriate applications. 309.5.4 All materials used in the subdivision water system shall not contain any lead substances. 309.5.5 All fire hydrants shall be three-way traffic models with a minimum five and one-fourth-inch valve opening, one pumper nozzle (four and one-half-inch pumper connection) and two (2) hose nozzles (one and one-half-inch hose connection). Cities recommended standards are as follows (American Darling Fire Hydrants or Mueller). a. Each hydrant shall have National Standard Threads. b. All fire hydrants shall be painted red (for private developments), and painted yellow for all hydrants in public developments. 309.5.6 Gate valves shall meet AWWA C-5OO. Valves shall be DD, NRS, IBBM with MJ ends. 309.5.7 MJ fittings shall be compact ductile iron AWWA C-153. All MJ bells shall be equipped with EBBA MEGA- LUG retainer gland C-900 PVC or ductile/cast iron pipe. 309.6 Pipe installation should comply with generally accepted standards of good workmanship, including applicable AWWA and industry standards. 309.7 Separation of water and sewer mains as well as water main crossings of surface water bodies and ditches shall be in accordance with the current standards of the appropriate Mississippi State Authorities. 309.7.1 Water mains shall be located on opposite sides of the- street right-of-way from sewers where possible. 309.8 Fire hydrants shall be located throughout the subdivision so that there is a hydrant within the following distances to any possible structure, as measured along a fire apparatus access road or other approved route around the exterior of the facility or building: a. 500 feet for residentially zoned subdivisions. b. 350 feet for commercially or industrially zoned subdivisions. c. This requirement however is superseded by any more stringent standards in the current fire code adopted by the City of D'Iberville. 309.9 At every fire hydrant installation, a six (6) inch gate valve and box shall be installed between the main line and the fire hydrant. 309.10 The proposed subdivision water system shall be designed so that all water users are individually metered. 309.10.1 The Owner/Developer shall furnish and install all meter boxes. 309.10.2 The Owner/Developer shall purchase water meters to be installed in public right-of-way from the City of D’Iberville to insure compatibility with existing water systems. 309.10.3 The Owner/Developer is responsible for construction of any required meter vault. The meter vault shall be constructed in City right-of-way per City of D’Iberville standard details. 309.10.4 Meter boxes and vaults shall maintain a 24” clear zone in all directions, with no concrete, asphalt or other hard surfacing material within said clear zone. 309.10.5 Each lot shall be provided with two one-inch (1") service lines configured as follows: 2" tap to 1-½" split to 1" split. 309.10.6 Once a meter box has been installed, it shall not be relocated unless prior approval has been given by the City Building Official Public Works Department. 309.10.7 No irrigation meters shall be installed in meter vaults. 309.11 A sufficient number of valves should be provided for line maintenance and repairs. As a minimum, valves shall be placed at intervals of eight hundred feet (800’) four hundred feet (400’) in residential subdivisions and six hundred feet (600’) three hundred feet (300’) in commercial / industrial areas unless approved otherwise by Public Works Department. Valves shall be placed a maximum distance of three feet (3’) from hydrants. 309.11.1 “WV” shall be stamped into the curb marking the location of each water valve when such valve is not located in the street. “WV” Water Valve designation markers shall be cast into the curbs to provide a flush finish. Markers shall be placed at each valve location. Markers shall be constructed of cast aluminum. Color shall be Blue and resist weathering & fading. This shall not apply to any valve located within any street or roadway. 309.12 Flushing hydrants and valves should be installed on all dead-end lines, which hold more than 100 gallons of water, low areas, and in other places that might require flushing. 309.13 Pressure leakage tests should be completed and conform to the current AWWA Standard C 600, Section 4. 309.14 Disinfection and bacteriological testing shall be in accordance with the current standards as set forth by the proper Mississippi State Authorities. 309.14.1 All water used for chlorination and flushing of water lines shall be metered and paid for by the Owner/Developer. 309.15 Cross Connections - There shall be no physical connections between the distribution system and any pipes, pumps, hydrants, or tanks whereby unsafe water or any contaminants may be caused to enter the water system. 309.15.1 An appropriate backflow prevention device should be installed on each service connection where an existing or potential health hazard exists or where a hazardous hydraulic condition may be allowed to exist. 309.15.2 Prior to service being connected to the City's water system, all wells or water sources owned or used previously by the potential customer shall be physically disconnected from the plumbing to be supplied by the City's water system. 309.16 The Owner/Developer shall provide a letter of design approval from the Mississippi Department of Environmental Quality. 309.17 Backflow Prevention Devices and Screening a. Backflow prevention devices shall be located subsurface outside the public right-of-way in a meter box or similar enclosure where possible. The Developer/ Owner will be responsible for all maintenance & repair of the backflow preventer assembly & the enclosure. b. When located above ground, the backflow preventer shall be screened from public view utilizing any of the following methods. i. Artificial rock cover or similar artificial landscaping device. ii. Vegetative plantings. 1. Landscaping material should include species that are low maintenance and drought tolerant. 2. Landscaping material, at the time of planting, shall be as tall as the backflow prevention device to be screened. When the backflow prevention device exceeds 18 inches in height, the landscaping material shall be at least half as tall as the device in order to provide immediate visual relief iii. Wall / Fencing 1. The screening structure shall be opaque and of similar material to that of the principal building. 2. The height of the screening structure shall be no higher than necessary to provide adequate screening. 3. The length and width of the screening structure shall not exceed the area necessary to provide adequate screening and access to the backflow prevention device. iv. Any other means or method of screening approved in writing by the Public Works Director. c. Backflow prevention devices and screening located within the traffic visibility triangle shall be located so that vision between a height from two to ten (2' to 10') feet above the centerline grades of streets and driveways is not obscured. d. In case of multiple backflow prevention devices on the same property, the devices shall be located together such that they can be screened together to the extent possible. e. In new construction when located above ground, every effort should be made to locate the backflow preventer behind the front building setback line when possible. f. Maintenance and repair of above ground screening shall be the responsibility of the property owner. i. The property owner shall maintain all screening devices in accordance with all applicable City codes and ordinances. ii. The property owner shall repair any damaged portion of the screening or replace the damaged portions in kind.

Ask a question about D'Iberville law

Corpus searches the D'Iberville sections it holds and shows the ones that match, with their citations. Free, no sign-in.