SECTION 501 RATE OF STORM WATER DISCHARGE
501.1 Drainage facilities and site grading shall be designed and provided to prevent excessive runoff onto adjacent properties.
501.2 Rate and velocity of discharge shall be determined at each point where post-development storm water leaves the property being developed in its pre-development state.
501.3 The storm water management system shall be designed so that there are no adverse effects downstream and the peak flow rate and velocity at any discharge point in the post- development state shall be less than or equal to the peak flow rate and velocity for the discharge point in the pre-developed state for the 2- year, 5-year, 10-year, 25-year, 50-year and 100-year 24-hour storm events. This shall be achieved using detention/retention basins, swales, pipe networks, grading, etc.
501.4 A developer/engineer may elect to detain only part of the proposed site; however, the total post-development flow must still be less than the pre-development flow at each point where storm water leaves the property being developed.
501.5 Pre-existing flow patterns, distributions, and exit locations should be mimicked in the developed conditions (aka Post or Post Developed).
501.6 Over-detaining a portion of the site will not be allowable if it results in increased direct- discharge flows leaving the property in other locations.