4.6. Design Report.

The application for permit shall contain a design report for the landfill facility that includes the following components, in order: 1. Facility Summary. A facility summary shall be included with the application for a permit. This facility summary shall contain the following information: a. Name of the applicant, including address and phone number. b. Street address and phone number of the facility for which a permit is requested. c. A list of the types and sources of waste to brought to the facility (e.g. residential waste, commercial waste, liquid waste, solid waste, and/or industrial waste) including a brief description of the composition of each waste stream. d. The average and maximum daily quantities of each type of material anticipated to be brought to the facility during the term of the permit. e. The estimated daily volume of site generated truck traffic including the numbers of inbound and outbound trucks by vehicle type (e.g. packer truck, transfer trailer, tanker truck, roll-off, etc.) and the anticipated peak hour site traffic. f. The total number of full-time and part-time employees at the facility. g. The current zoning district of the facility. h. A brief description of the operations at the facility. i. The facility operating hours. 2. Facility Safety Overview. A facility safety overview shall be included with a permit application. The purpose of the facility safety overview is to provide city personnel who may inspect the facility with a basic understanding of potential hazards and safety procedures. The facility safety overview shall include the following information: a. A description of the personal protective equipment to be worn by non-employees to the facility. b. A description of the potential hazards present at the facility. c. A summary of facility check-in and escort procedures. d. A summary of facility evacuation procedures. e. A summary of any other applicable facility safety procedures. 3. Plot Plan. The design report shall contain a plot plan drawing(s) of the landfill facility. This drawing(s) shall be prepared at a legible scale, no smaller than one inch equals 200 feet. The plot plan drawing(s) shall include the following components, at a minimum: a. The new landfill facility and/or expansion site boundaries and the location of all facility buildings, access roads, parking areas, and any ancillary structures or features. b. Include topographic contours at a minimum two-foot contour interval of the facility property. In areas of steep relief, a minimum 10 foot contour interval may be used to enhance clarity. c. For new facilities include a minimum buffer zone as required by MDEQ and the Conditional Use permit, whichever is more stringent. d. Indicate the limits of waste disposal, waste storage, and/or waste handling areas. e. Indicate all streams, rivers, ponds, lakes, and wetlands. f. Indicate all residence and property zoned as residential within 1000 feet of the property boundary. g. Indicate that extent and composition of the buffer zone required by the City of Gautier. h. Any special characteristic or feature of the property. The plans shall identify the characteristic or feature and indicate the setback distance from the landfill facility boundary. 4. USGS Site Location Map. The design report shall contain a USGS 7.5 Minute Quadrangle Map that provides sufficient coverage to include the following: a. The delineated boundaries of the landfill site. b. A clearly marked one-mile radius around the entire site to identify features including residential property, streams, rivers, ponds, lakes, wetlands, roads, highways, schools and parks within this one-mile perimeter. 5. Aerial Photograph Drawing(s). For new and expanding facilities the design report shall contain an aerial photograph drawing(s) that provides sufficient coverage to include the following: a. The delineated boundaries of the landfill facility and site property. b. A clearly marked 1/2-mile radius around the entire site to identify features including residential property, streams, rivers, ponds, lakes, wetlands, roads, highways, schools and parks within this ½-mile perimeter. c. Zoning districts clearly delineated with a ½-mile radius of the facility site. The district boundaries and their respective designations shall be clearly marked. 6. General Layout of the Facility. The design report shall contain sufficient scale drawings to describe the general layout of the facility. These drawings, at a minimum, shall illustrate the following: a. A scale no smaller than 1 inch equals 200 feet. The scale shall be represented on each sheet in graphical format. b. The external layout of buildings and structures. c. The layout and location of all fixed equipment. d. The limits of waste disposal, waste storage, and/or waste handling areas. e. All pertinent features of the stormwater management system. f. All pertinent features of the wastewater management system. g. The locations of the primary utilities within and adjacent to the landfill. h. The locations of the primary water sources and water distribution system components for employee consumption, fire suppression, facility cleaning, and dust control. i. The locations of all fire suppression equipment and flammable material storage areas. j. The locations of all site control features and all screening devices such as fences, gates, and signage. k. The locations and layout of all parking and queuing areas. l. The locations and layout of all employee facilities. m. The location of all first-aid equipment and other emergency supplies and equipment. 7. Survey. The design report shall contain a Legal Plat of Survey, prepared by a Professional Surveyor that depicts the landfill facility boundaries and the boundaries of the disposal unit or units. The landfill site shall have a minimum of two permanent survey monuments. The plat of survey shall illustrate the coordinates of these monuments in state plane coordinates and on-site coordinates. The elevation of each monument shall be determined in man sea level and Gautier City Datum. a. Wetlands. The survey shall contain a Wetlands Delineation or a statement from the engineer that no Wetlands exist on the property. b. 100-Year Flood Plain. The survey shall reflect that the landfill facility or expansion is located outside of the 100-Year Flood Plain, unless the landfill facility can demonstrate compliance with the City of Gautier’s Flood Damage Prevention and Control Ordinance and all other state and federal requirements. 8. Legal Description. The design report shall contain legal descriptions, prepared by a Professional Surveyor, that describe the landfill facility boundaries and the boundaries of disposal unit or units. The legal descriptions shall include the area contained within each boundary. 9. Utilities. For new and expanding facilities, the design report shall demonstrate that adequate utility capacity is readily available for the operations of the landfill facility. Utilities may include, but are not limited to: electricity, potable water, process water, telephone, and natural gas. The information in the design report regarding utilities shall include: a. A plan scaled drawing showing the location of all utilities within and adjacent to the landfill facility. b. Calculations demonstrating what the peak utility demands are for proper operation of the landfill facility. This shall include, but is not limited to, peak water, sewage and gas and/or electrical demands. c. A demonstration that sufficient utility capacity is available. Such documentation may be in the form of an approval letter or permit from the utility provider. 10. Water Sources. The design report shall demonstrate that sufficient quantities of water or other appropriate materials for employee’s consumption, fire protection, dust control, and cleaning are available. For this demonstration, the design report shall include: a. The locations of each source of water and/or other material. b. The total amount of water and/or other materials available from each source. c. The rate at which water and/or other materials can be obtained from each source. d. A listing of equipment and its specifications that is used to pump, distribute and/or convey water and/or other materials. 11. Site Security. The design report shall demonstrate that the landfill facility is secure from unauthorized access at all times. This demonstration shall include at a minimum: a. A description and specifications of the fences, gates, and other barriers that prevent unauthorized access to the landfill facility. b. A description of the security measures taken when the landfill facility is opened and closed. 12. Back-up Capacity. The design report shall demonstrate that the facility has provisions for the removal, storage, or covering of wastes in the event of an equipment failure or emergency situation. This demonstration shall include at a minimum: a. Details and calculations demonstrating that provisions exist for the removal, storage, or covering of wastes in the event of an equipment failure or emergency situation. b. A plan for restricting the flow of material into the facility during emergencies, equipment failures or maintenance including the decision criteria for implementing the plan. c. Detailed descriptions of procedures necessary to remove, containerize, or otherwise dispose of waste in the event that disposal in the current operating area is restricted or stopped. 13. Geotechnical Data. The applicant must provide Geotechnical Data and a Soils Report. 14. Water Drainage. The design report shall demonstrate that adequate systems exist to handle stormwater and wastewater flows from the landfill facility. This demonstration shall include: a. Drawings, specifications, and design calculations to demonstrate effective control of run-on and run-off from the landfill facility. b. Copies of the facility’s MDEQ discharge permits or anticipated submittal date, if applicable and/or any other applicable permits issued. c. Documentation that any receiving sewer system has sufficient capacity to handle the quantity of stormwater generated by the landfill facility. Such documentation may be in the form of an approval letter or permit from the utility provider. d. Drawings, specifications, and design calculations to demonstrate effective handling, storage, treatment, and/or disposal of leachate generated by the landfill facility. e. Demonstration that the landfill facility or expansion will not impact existing outfalls, natural or man-made drain ways, or conveyances. f. Demonstration that any receiving sewer system has sufficient capacity to handle the quantity of leachate generated by the landfill facility. 15. Traffic. The design report shall demonstrate that traffic generated by the landfill facility will not significantly affect existing traffic flows, and that the points of ingress and egress are designed according to Mississippi Department of Transportation (MDOT) standards. For new, expanding, and existing facilities, this demonstration shall include, but not be limited to: a. Calculations of the average and maximum number of vehicles generated by the landfill facility as well as an hourly breakdown of vehicle traffic. b. Diagrams of the points of ingress and egress depicting the layout of the ingress/egress points, sight distances, and improvements necessary to minimize accidents at the ingress/egress points. c. A listing of roads and highways designated for use by traffic generated by the landfill facility. d. A demonstration that traffic generated by the landfill facility will not interfere with the flow of traffic or exceed the intended level of service of any public street or right-of-way. e. A description of the measures taken to reduce the impact of the landfill facility generated traffic on the existing traffic flows. 16. Parking. The design report shall demonstrate that sufficient parking exists at the facility. This documentation shall include, but not be limited to: a. A listing of the number of employees at the landfill facility and the corresponding number of parking spaces. b. A layout of all parking areas including short-term truck parking and truck queuing areas. This layout may be shown on the general layout required in Section 4.6(6). 17. Employee Facilities. The design report shall contain a description of the employee facilities available at the site. At a minimum, these employee facilities shall include washrooms, toilets, and potable water. 18. Screening. The design report shall demonstrate that the screening or fencing of the facility will adequately control noise, dust, blowing litter, and will prevent unauthorized access to the site. This demonstration shall include, but not be limited to: a. A description of the screening or fencing for the landfill facility. b. A detailed drawing of the construction of the screening or fencing and the placement around the landfill facility. This drawing may be included in the general layout required in Section 4.6(6). c. A demonstration that the screening or fencing will control noise, dust, blowing litter, and unauthorized access. 19. Buffer Zone. The design report shall describe the buffer zone surrounding the facility and shall demonstrate that it meets the definition of a buffer zone required for a landfill by this ordinance. This demonstration shall include: a. A description of the buffer zone required for this facility by this ordinance. b. A drawing clearly depicting the extent of the buffer zone and identifying the applicable characteristics of the buffer zone. c. An analysis of the effectiveness of the buffer zone. 20. Monitoring Wells. The operating plan shall contain the locations of proposed monitoring wells for the facility and specific details concerning the monitoring well construction and locations. This shall include, but not be limited to: a. Drawings indicating the location of all monitoring wells and piezometers for the facility. b. Construction details for all monitoring wells and piezometers. c. A demonstration that the location and the horizontal and vertical spacing of well screens is sufficient to detect a release from the landfill. The application shall demonstrate that the well screens are located such that if a release is detected, there is sufficient area and time to implement remediation measures that will minimize or prevent the release’s impact beyond the property boundary. d. A description of monitoring well abandonment procedure which detail any backfilling or sealing including a demonstration that an abandoned well will not serve as a potential contaminant pathway. e. If monitoring wells are not proposed, applicant must demonstrate an alternate plan which must achieve the same result and which has been approved by Mississippi Department of Environmental Quality as part of their permitting process. 21. Liner. The design report shall contain documentation to demonstrate that the liner system is designed and constructed to prevent contamination of the surrounding environment. 22. Cover. The design report shall contain information regarding the various cover materials intended for use at the facility. This information shall demonstrate that the cover materials effectively contain the waste and minimize infiltration of stormwater into the landfill. 23. Landfill Grade. The design report shall contain a final grading plan and a demonstration that the final slopes are stable and are designed to prevent erosion of the final cover system. This plan and demonstration shall include, but not be limited to: a. A topographic map of the proposed final contours of the facility. b. A topographic map of the existing grades at the facility. c. An erosion control plan describing the methods used to prevent erosion of the final cover system. This plan shall also include inspection, maintenance, and repair procedures for maintaining the integrity of the final cover system. d. A demonstration that the maximum elevation of waste placement at the landfill shall not exceed the maximum elevation established in the permit at any time during the life of the facility.

Ask a question about Gautier law

Corpus searches the Gautier sections it holds and shows the ones that match, with their citations. Free, no sign-in.