Sec. 14-57. - Structural standards.

(a) Foundation. Foundations shall conform to the following: (1) Beneath the building there shall be firm ground, which is reasonably dry, properly drained and no water running under the building. (2) There shall be sound footings capable of providing adequate bearing. (3) Piers shall be sound with no loose mortar or masonry. (4) There shall be no piers in which the plumb line from the top center falls outside the middle one-third of the pier base. (5) There shall be no isolated solid masonry piers exceeding in height ten times the least dimension of the pier. (6) There shall be no wood stiff-knee or other improper piers allowed. (b) Floors. Floors shall conform to the following: (1) There shall be no decayed, termite-damaged, fire-damaged, broken, overloaded or sagging sills. (2) Sills shall be properly supported and reasonably level. (3) Joists shall not be overloaded, sagging or broken, and shall be structurally sound and not likely to cause structural weakness in the future. (4) Maximum spans for floor joists and sills, provided that they show signs of being weak or overloaded, shall comply with the requirements of the state residential building code. (5) Flooring shall be weathertight without holes or excessive cracks which permit air to penetrate rooms. (6) Flooring shall be reasonably smooth and not decayed, fire damaged or excessively worn. (7) There shall be no loose flooring. (8) Floors shall be reasonably level. (9) The flooring in each room shall consist of the same or similar material, impervious to water; and where covering or finishing is provided, such covering or finishing shall be reasonably smooth for sanitary maintenance and not excessively worn. (c) Walls, exterior. Exterior walls shall conform to the following: (1) There shall be no wall in which the plumbline from the top center of studs falls outside the base plate at any point along the wall. (2) Maximum spacing for studding, providing they show signs of being weak or overloaded, shall comply with the requirements of the state residential building code. (3) Studs shall be structurally sound and not likely to cause structural weakness in the future. (4) There shall be no broken or cracked structural members. (5) All siding shall be painted or treated to be weathertight, with no holes or excessive cracks or decayed boards which permit air to penetrate rooms. (6) There shall be no loose siding. (7) There shall be no deterioration because of lack of preventive maintenance consisting of painting, waterproofing and repair. (d) Walls, interior. Interior walls shall conform to the following: (1) Interior finish shall be free of holes and excessive cracks which permit air to penetrate rooms. Paint or wallpaper, shall be free of chips or excessive peeling. (2) There shall be no walls in which the plumbline from the top center of studs falls outside the base plate at any point along the wall. (3) There shall be no loose plaster, loose boards or other loose wall materials. (4) There shall be no cardboard, newspaper or highly combustible or improper wall finish; and all wall materials shall be of the same or similar quality and material. (5) Maximum spacing for studding, providing they show signs of being weak or overloaded, shall comply with the requirements of the state residential building code. (6) Studs shall be structurally sound and not likely to cause structural weakness in the future. (7) There shall be no broken or cracked studs or other structural members. (e) Ceilings. Ceilings shall conform to the following: (1) There shall be no joists which are decayed, broken, sagging or improperly supported at the ends. (2) Maximum spacing for ceiling joists, providing they show signs of sagging and being weak, shall comply with the requirements of the state residential building code. (3) Maximum spans for ceiling joists, provided that they show signs of being weak or overloaded, shall comply with the requirements of the state residential building code. (4) There shall be no loose plaster, boards, gypsum wall board or other ceiling finish. (5) There shall be no holes or excessive cracks which permit air and dust to penetrate rooms. (6) There shall be no cardboard, newspaper, highly combustible or improper ceiling finish; and all ceiling materials shall be of the same or similar quality and material. (7) Ceiling joists shall be structurally sound and not likely to cause structural weakness in the future. (f) Roofs. Roofs shall conform to the following: (1) There shall be no rafters which are decayed, broken or improperly supported at the ends. (2) No rafters shall be seriously damaged by fire. (3) The attic shall be properly ventilated. (4) Sheathing shall not be loose and shall be structurally sound and not likely to cause structural weakness in the future. (5) There shall be no loose roof covering, no holes, and no leaks causing damage to the structure or rooms. (6) There shall be a minimum of class C roof covering. (7) There shall be proper flashing at walls and/or chimneys. (g) Porches. Porches shall conform to the following: (1) The floor, ceiling, and roof shall be equal to requirements set forth in this section, except sills, joists and floors need not be level if providing drainage of floors; floors need not be weathertight; the ceiling height may be seven feet; and the attic need not be vented. (2) If required to be replaced or if no railings or guards are provided, each porch, terrace or entrance platform located more than 30 inches above adjacent finished grade shall be equipped with railings or guards not less than 36 inches high, and shall have pickets installed so as not to allow a sphere greater than six inches to pass through. Horizontal spacing between the vertical members in required guardrails shall be a maximum of four inches at the nearest point between the members. (3) If post and railings are provided, they shall be structurally sound and not likely to cause structural weakness in the future. (h) Stairs and steps. Stairs and steps shall conform to the following: (1) Stairs and steps shall be free of holes, grooves and cracks large enough to constitute accident hazards. (2) Stairwells and flights of stairs more than four risers high shall have rails on at least one side and a guardrail on all open sides not less than 30 inches nor more than 38 inches, measured vertically from the nose of the treads to the top of the rail. (3) Every rail shall be firmly fastened and maintained in good condition. (4) No flight of stairs shall be settled more than one inch out of its intended position or pulled away from supporting or adjacent structures. (5) Supports shall not sag and shall be structurally sound and not likely to cause structural weakness in the future. (6) Every stair riser shall be reasonably uniform in height, and treads shall be sound and securely fastened in position and strong enough to bear a concentrated load of at least 300 pounds without danger of breaking through.

(Code 1987, § 4-53)

Ask a question about Concord law

Corpus searches the Concord sections it holds and shows the ones that match, with their citations. Free, no sign-in.