Sec. 14-59. - Ventilation.
(a) Every habitable room shall have at least one window or skylight facing directly to the outdoors. (b) The minimum total window area, measured between stops, for every habitable room shall be eight square feet or eight percent of the floor area of such room. (c) The total of openable window area in each habitable room shall be equal to at least one-half of the required minimum glazed area. (d) Bathrooms, water closet compartments and other similar rooms shall be provided with aggregate glazing in windows or not less than three square feet, one-half of which must be openable. (e) Windows in bathrooms shall not be required where artificial light and an approved mechanical ventilation system capable of producing a change of air every 12 minutes are provided.
(Code 1987, § 4-55)