Sec. 14-58. - Basic equipment and facilities.
(a) Plumbing system. (1) Each dwelling unit shall be connected to a potable water supply system. The term "potable water supply" means direct connection to a well, to a public water utility or equivalent approved water service delivery system. (2) Every dwelling unit shall contain not less than a kitchen sink, lavatory, tub or shower, and water closet with an adequate supply of both cold water and hot water properly connected to an approved public sewer disposal facility or a sewer system approved by the county health department. (3) Every plumbing fixture shall be equipped with safety shutoff valves and maintained in good sanitary and working condition, free from leaks, defects and obstructions in compliance with the standards of the state plumbing code. (4) Every dwelling shall have a water heater equipped with approved relief valves and properly connected to deliver hot water to the kitchen sink, lavatory, tub/shower and laundry area. (5) All required plumbing facilities, such as water closets, tub and/or shower shall be accessible to all occupants affording privacy to the user. (b) Heating system. (1) Every dwelling shall have a heating system, central or other, properly installed and maintained in a good and safe working condition capable of adequately heating and maintaining all habitable rooms and bathrooms to a minimum temperature of 68 degrees three feet above the floor between November 1 and March 31 of any year. (2) Where a central or electric heating system is not provided, each dwelling and dwelling unit shall be provided with sufficient fireplaces, chimneys, flues and gas vents whereby heating appliances may be connected so as to heat all habitable rooms to the minimum temperature of 68 degrees three feet above the floor during winter. (3) All heating systems shall be properly vented. a. There shall be no holes in flues. b. Thimbles shall be grouted in tightly and shall not be cracked or broken. c. Chimneys shall not have any loose bricks. d. There shall be no hanging chimneys. (c) Electrical system. (1) Lights and outlets. Lights and outlets shall conform to the following: a. No receptacles, ceiling fixtures, or other fixtures shall be hanging loose. b. All switches and receptacles shall be safely operable. c. Every habitable room shall contain not less than two wall-type electrical convenience receptacles. d. There shall be installed in every habitable room, bathroom, laundry room, hallway, stairway and furnace room at least one supplied ceiling or wall-type electrical light fixture; provided, further, that the ceiling light fixture may be omitted in living room and bedrooms, provided that three electrical convenience receptacles are installed, one of which is controlled from a wall switch. e. There shall be no unsafe wiring and all wiring shall be installed in accordance with the National Electrical Code. f. There shall be no drop or extension cords in excess of six feet in length. g. No circuits shall be overloaded. h. Fuses shall be sized correctly and not bridged out. i. Every public hall and stairway in every multiple dwelling shall be adequately lighted by electric lights at all times. (2) Smoke detectors. A minimum of one 120-volt permanently connected automatic smoke detector shall be installed in all dwelling units on each habitable floor level and basement. Floor levels containing one or more sleeping areas shall have a smoke detector installed inside and outside each sleeping area. All required smoke detectors shall be supplied by a branch circuit serving one or more of the required lighting outlets and permanently connected ahead of switching devices. (3) Electric service. a. Adequate electric service must be provided to the dwelling. The term "adequate" means a minimum of 60 ampere service with no more than five two-wire branch circuits connected and a total connected load of less than ten kilowatts. If a service has six or more two-wire branch circuits, 100 ampere service at a minimum must be provided. If the connected electrical load exceeds the capacity of a 100 ampere service, a service of sufficient ampere capacity to safely bear the connected electrical load shall be furnished. Drop cords from a neighboring source, generator or similar source are not adequate for purposes of this code. b. Every new or additional electrical outlet and fixture required by the code shall be installed, maintained and connected to a source of electric power in accordance with the provisions of the state building code.
(Code 1987, § 4-54)
Ask a question about Concord law
Corpus searches the Concord sections it holds and shows the ones that match, with their citations. Free, no sign-in.