For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 70-582 — Definitions

Code of Ordinances, City of Durham, North Carolina (Supp. No. 37, Update 1: codified through Ordinance No. 16682, adopted June 15, 2026) · Durham City Code § 70-582

Corpus is an independent public-information project, not the official City of Durham website. Stable reference: corpuslaw.us/code/ddedd0b5-e280-4e28-8078-ce10ade1d876

Sec. 70-582. - Definitions.

The following definitions shall apply to this Article: "A" class certified tester means a certificate is issued to fire sprinkler contractors licensed by the State of North Carolina (NC) for the purpose of testing any backflow preventer and limited to installation, cleaning, repairing, and/or replacing only fire protection backflow preventers. Testers may be included on the City of Durham's Certified Testers list. Accessible (access to) means capable of being reached for testing and maintenance; however, it first may require the removal of an access panel, door, dirt, sod, or similar obstruction. Administrator means CCC Administrator; the official in the Department designated by the director to perform certain functions regarding administration of the city's CCC Program. Air gap means a physical separation between the free-flowing discharge end of a potable water supply pipeline and an open or non-pressure receiving vessel. An "approved air gap" shall be at least twice the diameter of the supply pipe measured vertically above the flood-level rim of the receiving vessel, in no case less than one inch (2.54 centimeters (cm)). An air gap is the only absolute method for preventing backflow, however it is the easiest to alter or breach. Approved means meeting the standards for cross connections or certified in writing as acceptable by the CCC Administrator, provided that such certifications do not contradict the standards. Approved backflow prevention assembly (BFPA) means an assembly that has been approved for use by the Department of Water Management [DWM] CCC Group. Approval of a BFPA includes the approval of shut-off valves (SOV) and test cocks (TC) (and is in-line testable). Atmospheric vacuum breaker (AVB) means a device that prevents backsiphonage by creating an atmospheric vent when there is either negative pressure or sub-atmospheric pressure in a water system; it includes those devices permanently attached to a hose bibb (e.g., hose bibb vacuum breaker [HBVB]). (e.g. ASSE 1001). Auxiliary intake/water means any water supply on or available to a consumer's property other than the city's approved public potable water supply. Auxiliary waters may include water from another purveyor or any natural source (e.g., well, spring, any unknown water source). "B" class certified tester means a certificate is issued to personnel who are employed and work at a facility owned by their employer for the purpose of testing BFPAs on their premises only; and testers, without contractor licenses, who test in other jurisdictions. BFPA testing is authorized under this class. No internal cleaning, repair, or replacement work is authorized. Backflow means the undesirable reversal of flow of a liquid, gas, or other substance in a potable water distribution piping system at a cross connection. Backflow permit means a document issued by DWM that authorizes a particular action or use of a particular BFPA or another device. Backflow preventer (BP) means an assembly, device, or method that prevents the backflow of water into potable water supply systems. (Note: The definitions of specific backflow preventer types provided in the American Water Works Association (AWWA) Manual of Water Supply Practices M14: Recommended Practice for Backflow Prevention and Cross Connection Control are adopted by reference, including subsequent amendments and editions.) Backpressure means a form of backflow where the pressure in the user's water system is greater than the city's water distribution system pressure which can cause a reversal of the normal direction of flow (e.g., booster pumps, lawn irrigation, equipment that allows for extreme temperature increases (e.g., boiler], elevation differences). Backsiphonage means a form of backflow due to the supply line pressure falling below atmospheric pressure (14.7 pounds per square inch (psi) at sea level) or a reduction in system pressure resulting in sub-atmospheric pressure in the water system. (e.g., water line flushing, firefighting, breaks in the water mains). Bypass means any arrangement of pipes, plumbing, or hoses that divert flow around an installed backflow device (BPD) or BFPA through which the flow normally passes. "C" class certified tester means a certificate is issued to a contractor (i.e., plumbing and utility contractors) licensed by the State of North Carolina for the purpose of installing, cleaning, testing, repairing, removing, or replacing any BFPA. Testers may be included on the City of Durham's certified testers list. CCC administrator means staff within the City of Durham responsible for the implementation and enforcement of the CCC Program as defined by this article and the Standards. CCC policy means the written requirements approved by the Durham City Council, and maintained by the department, in the City of Durham Reference Guide for Development, paper and online, that meet, at a minimum, the Federal, State, and local cross connection control regulations (see the definition for Standards). Certified tester means a person who meets minimum requirements for "A" Class Certified Tester, "B" Class Certified Tester, or "C" Class Certified Tester which include successful completion of a training program approved by the DWM Director and performance of work that meets standards outlined in the CCC Policy document. Commercial property means a property that includes office buildings, industrial facilities, institutional facilities, medical centers, hotels, retail stores (including malls), farmland, multi-family housing (e.g., apartment complexes, condominiums), warehouses, and commercial garages. Refer to the definition of non-residential. Consumer means any person, firm, or corporation responsible for any property at which water from the city's water distribution system is received. In the absence of other parties or failure of the other parties to accept responsibilities herein set forth, the owner of record shall be ultimately responsible. Containment means when backflow preventer(s) (BP) are installed downstream of the primary water meter and before any branching or point of use connections to contain any contaminants in the consumer's system from backflowing into the city's water distribution system. Contamination means the introduction of any substance that negatively impacts the quality of water supplied by the city presenting a hazard to public health (e.g., severe illness or death). Contractor means an individual, firm, or corporation that undertakes a contract to provide materials or labor to perform a service or do a job. Customer means see definition of consumer. Cross connection (CC) means an actual or potential physical connection between any part of a water system and any other environment containing other substances in a manner that under certain circumstances allow such other substances to enter the potable water system. Other substances may be gases, liquids, or solids. Other substances may be chemicals, water products, steam, water from other sources (potable or non-potable), or any matter that may change the color or add odor to the potable water. Cross connections include, but are not limited to, bypass arrangements, jumper connections, removable sections, swivel or changeover assemblies, or any other temporary or permanent connecting arrangement through which backflow may occur. CCC group means City of Durham employees in the CCC Program that are responsible for the implementation and enforcement of this article and the standards. CCC program means a program to eliminate, monitor, protect, and/or prevent unprotected cross connections from allowing backflow. Dead end lines means a water line extending more than 50 feet from the city's water main. Department means City of Durham Department of Water Management Device (BPD) means a backflow prevention mechanism only, not in-line testable. Director means City of Durham Department of Water Management Director. Drinking water supply system means the piping that distributes potable water supplied by the city. (Note: The system on the street side of the water meter is the "City's Water Distribution System." The system on the user's side of the water meter is the "User's Water Supply System.") Double check detector assembly (DCDA) means a specially designed BFPA composed of a line-sized-approved DC with a bypass containing a specific water meter and an approved DC; the meter shall register accurately for only very low flow rates up to three gallons per minute (gpm) and shall show a registration for all rates of flow; this assembly shall only be used to protect against a Low Hazard (Non-Health/Moderate) (i.e., pollutant). (e.g. ASSE 1048). Double check valve assembly (DC) means a complete assembly consisting of two internally loaded, independently operating check valves, located between two tightly closing, resilient-seated shutoff valves with four properly placed resilient-seated test cocks; this assembly shall only be used to protect against a low hazard (Non-Health/Moderate) (i.e., pollutant). (e.g. ASSE 1015). Dual check valve device (DUC) means a device that contains two spring-loaded, independently operating check valves in series, without tightly closing shut off valves and test cocks (e.g. American Society of Sanitary Engineers [ASSE] 1022, 1024). Employees exempted from licensure means an unlicensed person who is directly and regularly employed in the ordinary course of business by a contractor licensed pursuant to General Statute 87, Article 2. Fire line means a system of pipes and equipment for a fire protection system (FPS) used to supply water for the purposes of extinguishing a fire. High hazard (health/severe) means a substance that can adversely affect human health and safety. Hose bibb means an outside spigot or faucet located on the exterior of a building. In-ground means an installation below ground or below finished grade, including, but not limited to below concrete, sod, mulch, pine straw, or sand. An in-ground piping system is any in-ground piping, sprinklers, drip tubing, valve, control wiring of 30 volts or less, and associated components, thereby making the in-ground piping not readily accessible (see definition of readily accessible below). Irrigation means the supply of water to land to assist with vegetative growth (e.g., grass, trees, shrubs, flowers). (See Irrigation System.) Irrigation contractor means any person who, for compensation or other consideration, constructs, installs, expands, services, or repairs irrigation systems. An irrigation contractor that is not a licensed plumber may only perform work downstream of an irrigation system backflow preventer. Irrigation system means all piping, fittings, sprinklers, drip tubing, valves, control wiring of 30 volts or less, and associated components installed for delivery and application of water for the purpose of irrigation. Inspector means a qualified individual certified through the NC Code Officials Qualifications Board to serve as a code official employed by local and state government. Isolation means providing a BP at each cross connection found within the customer's facility to protect and isolate the potential cross connection water line from the remainder of the facility's potable water supply. Lock wing (valve) means a type of lockable shut-off valve to isolate an individual tenant of a building that is primary metered. This type of lockable valve is required for potential compliance and enforcement measures. Low hazard (non-health/moderate) means a substance that does not affect public health; however, it will affect the aesthetic quality of the water (e.g., taste, odor, color). Manufacturer air gap fitting means an unobstructed fitting that provides an air gap and allows for the connection between the water outlet relief valve of an approved reduced pressure type backflow preventer and indirect waste to convey normal discharge and nuisance spitting, ASME A112.1.3. An approved manufacturer air gap fitting shall be sized properly based on the outlet size of the relief valve. Meter means a device for measuring the number of gallons or cubic feet of water which passes through a pipe. Non-potable water means water of questionable quality that is not approved for drinking. Non-regulated public water system means a system for the provision of water to the public for human consumption, through pipes or other constructed conveyances, that serves 15 or more service connections or that regularly serves 25 or more individuals, but to which the scope of article 10 - North Carolina Drinking Water Act does not apply due to the regulatory exclusion criteria in North Carolina General Statute (NCGS) 130a-314. Non-residential means refer to the definition for Commercial Property. Non-willful violation means an act done without the intent to disregard the applicable federal, state, or city requirements or the standards. Notice of violation means a written notice provided to the user or owner of a property that identifies a violation and that includes a date by which the violation must be corrected in order to avoid the issuance of penalties or the initiation of additional enforcement measures. Operator in responsible charge (ORC) means a person assigned by the North Carolina Water Treatment Facility Operators Board (NCWTFOB) who is responsible for the administration of a CCC Program in partnership with the department and director. Owner means a person who owns property. Owner of record means the name of the party identified in the city's billing system as the water customer associated with a property or a unit within a property. Plumbing permit means a permit required for the installation, extension, or general repair of any plumbing system. (Refer to the North Carolina Administrative Code and Policies.) In Durham, plumbing permits are issued by the Durham City-County Inspections Department. Pollution means any substance that generally would not be a health hazard but would constitute a nuisance or be aesthetically objectionable if introduced into the potable water supply. (Also known as a Non-Health or Low Hazard.) Potable water supply means water approved for drinking or another household use (i.e., water that is safe for consumption and aesthetically pleasing). Pressure vacuum breaker assembly (PVB) means an assembly consisting of an independently operating, internally loaded check valve, and an independently operating, loaded air-inlet valve located on the discharge side of the check valve, with properly located resilient-seated test cocks and tightly closing resilient-seated shutoff valves attached at each end of the assembly designed to be operated under pressure for prolonged periods of time to prevent backsiphonage; the PVB may not be subjected to any backpressure. (e.g. ASSE 1020). Primary meter means a meter used to measure, for billing purposes, the total amount of water used in an entire building, including combined use from individually leased, rented, or owned units and all common areas. Readily accessible (ready access) means access that enables piping, fittings, sprinklers, drip tubing, valves, control wiring of 30 volts or less, and associated components to be directly reached without requiring the removal or movement of any panel, door, dirt, concrete, sod, mulch, sand, or other obstruction similar to those included in this list. Reduced pressure principle backflow prevention assembly (RP) means a BFPA containing an independently operating, hydraulically dependent relief valve located between two independently operating, spring-loaded check valves located between two tightly closing resilient-seated shutoff valves; the RP includes four properly located, resilient-seated test cocks. (e.g. ASSE 1013). Reduced pressure principle detector backflow prevention assembly (RPDA) means BFPA composed of a line-size approved RP with a bypass containing a specific water meter and approved RP; the meter shall register accurately for very low flow rates of up to three gpm, and shall show a registration for all rates of flow; this assembly may be used to protect against either a Low Hazard (Non-Health/Moderate) (i.e., pollutant) or High Hazard (Health/Severe) (i.e., contaminant) (e.g. ASSE 1047). Reference Guide for Development means the Reference Guide for Development shall serve as the technical code or standards applicable to infrastructure construction and development within the City. Residential property means property that is designated as a private dwelling (e.g., single-family home, or duplex); residential properties shall exclude multi-family housing (e.g., apartment complexes, condominiums). Service connection means the connection between the city's water distribution system main and the user's water system as defined by the NC Plumbing Code. Shut-off valve (SOV) means a handle that can be used to turn water on or off when it is connected to an inlet water pipe. Spill resistant vacuum breaker (SVB) means an assembly consisting of an internally loaded check valve and a load air-inlet valve located on the discharge side of the check valve; an inlet and outlet, resilient-seated, fully ported shutoff valve; and a properly located, resilient-seated test cock and vent valve designed to operate under pressure for prolonged periods of time to prevent backsiphonage; the SVB may not be subjected to any backpressure. (e.g. ASSE 1056). Standards means written requirements that shall serve as the technical code, issued and maintained by the Department that meet, at a minimum, the requirements of the Federal and State regulation (Refer to §70-581 and the CCC Policy), Reference guide for development, and the requirements of this article of the Durham City Code. The standards shall be maintained in a document available in paper and online that may bear any title, including, but not limited to, "manual", "requirements", "guidelines", "reference guide for development", or "policy." User means any person that uses the water from the city's water distribution system. Refer to the definition for consumer. Water hammer means a phenomenon that occurs in any piping system where valves are used to control the flow of liquids causing a knocking or shaking sound in the piping. Willful violation means an act done voluntarily with an intentional disregard of, or planned indifference to, the standards. Wye strainer means a device that mechanically removes solids from the potable water supply via a perforated or wire mesh strainer.

(Ord. No. 15942, § 1, 6-6-2022)

Ask a question about Durham law

Corpus searches the Durham sections it holds and shows the ones that match, with their citations. Free, no sign-in.