Sec. 70-584. - Standards.

The City of Durham shall promulgate standards that control actual or potential cross connections, and that promote the containment and isolation of potential contamination caused by cross connections. The standards shall be considered requirements of this article and are incorporated herein. These standards are contained in the city's Cross Connection Control Policy document. Among other things, the standards shall set forth the types of backflow preventers, including manufacturers and models that are approved for control of backflow from different types of cross connections. Backflow preventers addressed in the standards shall include the following: air gap, Due, RP, RPDA, DC, DCDA, PVB, SVB, AVB, and HBVB. The standards shall also address other activities necessary for the successful operation of the city's CCC Program, including installation, cleaning, maintenance, removal, relocation, testing, repair, plan review for building permit applications, permitting of backflow preventers, permitting of other activities (e.g., fire prevention system installation), and qualifications of certified testers. (a) Approved backflow preventers and devices. (1) Backflow device and assembly approval: a. Only ASSE approved or University of Southern California Foundation for Cross Connection and Hydraulic Research (USCFCCHR) devices or BFPAs will be permitted in the standards. b. An approved backflow preventer shall mean a device or BFPA that has been manufactured in full conformance with the standards established by the ASSE. c. BFPAs installed on fire protection systems shall be approved for installation on fire protection systems, be approved by Factory Mutual, and be in compliance with the National Fire Protection Association (NFPA) Code. (2) Manufacturers and Models. Installed devices or BFPAs shall consist of only those included in the most recent version of the ASSE International Seal Authorization Booklet or https://fccchr.use.edu/list.html. (b) Required permits. (1) Plumbing Permit shall be required for the installation of a new BFPA for new construction, renovations, and/or identification of a previously unprotected cross connection. A plumbing permit is not required for the replacement of a BFPA if the replacement is with the same type of BFPA (e.g., Replace an existing RP with a new RP) and there are no significant changes in piping; however, the new BFPA must be from an approved manufacturer and an approved model. Refer to §70-584(A)(2) for references listing approved manufacturers and models. (2) Users shall obtain a backflow preventer permit (also referred to as a cross connection control permit) for the installation, replacement, removal, or relocation of BFPAs prior to starting work. (3) A fire protection system permit is required for the installation of new and replacement BFPAs (other than like-for-like assemblies) on fire protection systems. (4) A building permit is required for any inspections, including CCC, for customers seeking a COC. (5) A CCC Plan Review Request application, along with payment of any applicable fees established by the city, shall be submitted in conjunction with the building permit application. (c) Installation requirements. (1) BFPAs shall be installed in conformance with the NC Building Code, manufacturer recommendations, and according to details and specifications approved by the director and ASSE or USCFCCHR. The installation requirements shall be described in the CCC Policy. (2) Internal components of BFPAs shall be lubricated only with approved, Food and Drug Administration (FDA) lubricants. (3) BFPAs that have been determined through annual or other testing (Refer to §70-588) to require cleaning, repair, or replacement must complete the cleaning, repairs, or be replaced within 15 days following a failing test results. (d) Containment. All non-residential water customers/ users shall have an approved BFPA, as defined in §70-584(A) installed on the potable water supply line, directly after the meter and prior to any tee-offs. This containment backflow isolates the entire property from potentially contaminating the city's water distribution system. Single family residences do not require a BFPA to be installed; however, a backflow prevention device (e.g., a DuC) is required to be installed immediately downstream of the water meter prior to any branches on the user's water system. (e) Other cross connections (Isolation). Cross connections to the city's water distribution system that do not occur at the point of water service or metering (Containment), and cross connections internal to the user's property or facilities require backflow preventers as identified in the CCC Policy to isolate an individual hazard from potentially contaminating the customers internal plumbing system. These cross connections and the approved backflow preventers for these cross connections are described in the standards. (f) Wye strainer. (1) An approved wye strainer shall be installed immediately upstream of each installed BFPA, excluding BFPAs in fire protection systems. (2) Wye strainers shall not be installed on fire protection systems, pre-fabricated bulk meters, or fire hydrant meters with backflow preventers issued by the city. (3) All approved wye strainers shall be installed per manufacturer and NC Building Code requirements. (4) The strainer provided in a pressure reducing valve is not an approved wye mesh strainer.

(Ord. No. 15942, § 1, 6-6-2022)

Ask a question about Durham law

Corpus searches the Durham sections it holds and shows the ones that match, with their citations. Free, no sign-in.