§ 26-301 — Responsibilities
Code of Ordinances of the City of Jacksonville, North Carolina (Codified through Ordinance No. 2025-52, adopted November 18, 2025 (Supp. No. 63)) · Jacksonville Code of Ordinances § 26-301
Corpus is an independent public-information project, not the official City of Jacksonville website. Stable reference: corpuslaw.us/code/1be993ef-d551-4db3-b936-e2ec59403f29
Sec. 26-301. - Responsibilities.
(a) State health agency. The North Carolina Department of Environment and Natural Resources (NCDENR), Division of Environmental Health, has the responsibility for promulgating and enforcing laws, rules, regulations, and policies to all water purveyors in the state in carrying out an effective cross connection control program. The state division of environmental health also has the primary responsibility of ensuring the water purveyor operates the public potable water system free of actual or potential sanitary hazards, including unprotected cross connections. They have the further responsibility of insuring that the water purveyor provides an approved water supply at the service connection to the consumer's water system; and, that the water purveyor require the installation, testing, and maintenance of an approved backflow prevention assembly on the service connection when required. (b) Water purveyor. Except as otherwise provided herein, the water purveyor's (city's) responsibility is to ensure a safe water supply beginning at the source and continuing throughout all of the public water distribution system, including the service connections, and ending at the point of delivery to the water system(s) of consumers. In addition, the city shall exercise reasonable vigilance to ensure that the consumer has taken the proper steps to protect the public potable water system. To ensure proper precautions are taken, the city is required to identify, prevent, and eliminate potential hazards to the public potable water system; to determine the degree of hazard or potential hazard to the public potable water system; to determine the degree of protection required; and to ensure proper containment protection through an on-going inspection program. (c) Plumbing inspector. The plumbing inspectors have the responsibility to not only review building plans and inspect plumbing as it is installed, but also to prevent cross connections from being designed and built into plumbing systems. Where the review of building plans indicates or detects the potential for cross connections being made an integral part of the plumbing system, the plumbing inspector has the responsibility, under the state plumbing code, to require that such cross connections be either eliminated or provided with an approved backflow prevention assembly. The plumbing inspector's responsibility begins at the point of delivery, downstream of the first installed backflow prevention assembly, or where the service line approaches private property and continues throughout the entire length of the consumer's water system. The inspector shall inquire about the intended use of water at any point where it is suspected that a cross connection may exist, or where one is designed for installation. When a cross-connection is discovered, a suitable, backflow prevention assembly approved by the University of Southern California (USC) shall be required. (d) Consumer. Each consumer has the primary responsibility of preventing pollutants and contaminants from entering his/her potable water system(s) or the public potable water system. The responsibility of each consumerstarts at the point of delivery from the public potable water system and includes all of his/her water system(s). To accomplish this, the consumer at his/her own expense, shall install, operate, test, and maintain an approved backflow prevention assembly. Each consumer shall maintain accurate records of tests and repairs made to backflow prevention assemblies and shall maintain such records for a minimum period of three (3) years. The records shall be on forms approved by the city and shall include the list of materials or replacement parts used, the dates of all tests and repairs, and the identity of the contractor. Following any repair, overhaul, re-piping, or relocation of a consumer's backflow prevention assembly, the consumer shall have it tested to insure that it is in good operating condition and will prevent backflow. Tests, maintenance and repairs of backflow prevention assemblies shall be made by a certified backflow prevention assembly tester. (e) Certified tester All backflow prevention assembly testers must become certified or re-certified every two (2) years through a state AWWA/WEA approved backflow prevention certification program. When employed by the consumer to test, repair, overhaul, or maintain backflow prevention assemblies, a certified tester will be responsible for: (1) Making competent inspections and repairing or overhauling backflow prevention assemblies and making reports of such repair to the consumer and responsible authorities on forms approved by the city, including the lists of materials and/or replacement parts used. (2) Being equipped with, and competent to use all the necessary tools, gauges, manometers and other equipment necessary to properly test, repair, and maintain backflow prevention assemblies. (3) Ensure that original manufactured parts are used in the repair of or replacement of parts in a backflow prevention assembly. (4) Not to change the design, material, or operational characteristics of an assembly during repair or maintenance without prior approval both the city and the public services department. (5) Provide a copy of all test and repair reports to the consumer and to the city within ten (10) business days of any completed test or repair work. A certified tester shall maintain such records for a minimum period of three (3) years. Performing the work and ensuring the accuracy of all tests and reports. All certified testers must obtain, and employ, backflow prevention assembly test equipment, that has been evaluated and/or approved by the public services department. All test equipment shall be checked for accuracy annually (at a minimum), and calibrated, if necessary, employing an accuracy/calibration method dictated by the manufacturer of the equipment acceptable to the city's cross connection section. Certification of the accuracy and calibration shall be provided to the public services department annually.
(Ord. No. 08-29, 6-17-08)
Ask a question about Jacksonville law
Corpus searches the Jacksonville sections it holds and shows the ones that match, with their citations. Free, no sign-in.
