§ 26-306 — Installation of assemblies
Code of Ordinances of the City of Jacksonville, North Carolina (Codified through Ordinance No. 2025-52, adopted November 18, 2025 (Supp. No. 63)) · Jacksonville Code of Ordinances § 26-306
Corpus is an independent public-information project, not the official City of Jacksonville website. Stable reference: corpuslaw.us/code/d9806e9a-b2a9-4b65-95e2-3520fd055350
Sec. 26-306. - Installation of assemblies.
(a) All backflow prevention assemblies shall be installed in accordance with the specifications furnished by the public services department and/or the manufacturer's installation instructions and /or in the latest edition of the state building code, whichever is most stringent. (b) All backflow installations will require a plumbing permit within the inspections and/or code enforcement jurisdiction of the work which is being performed. These permits can be obtainable from the city's inspections department. (c) All new construction plans and specifications, when required by the state building code and the state department of environmental health and natural resources shall be made available to the city for review and approval, and to determine the degree of hazard. (d) Ownership, testing, and maintenance of the assembly shall be the responsibility of the customer. (e) The backflow preventer must be installed directly behind the city's water meter service before any wyes, tees, or bypasses on the customers property. (f) By-pass piping is not permitted unless the by-pass piping is equipped with an approved backflow prevention assembly of the same type and brand as the main line assembly. It shall be necessary to install two (2) approved backflow prevention assemblies to ensure continuous water service. (g) All backflow preventers must be installed above ground including double check valves. Backflow preventers installed inside must be a minimum of twelve (12) inches above the floor, and no higher than four (4) feet above floor. Customer must maintain adequate clearance around the assembly for testing, and/or repair of the assembly. Wherever a reduced pressure principle backflow preventer is installed inside a building an air gap drain of adequate size must be installed. (h) Backflow prevention assemblies installed outside must be protected with an ASSE 1060 approved enclosure. The assembly must maintain a minimum distance of twelve (12) inches and a maximum of distance of thirty (30) inches above ground. Landscaping is allowed around any assembly provided it does not interfere with the testing and/or repairing of the assembly. Surface or sub-surface obstacles which prohibit the installation of the device in accordance with the specifications shall be subject to the review and approval of the public services director for alternative locations. (i) Protective enclosures must be used to prevent from freezing or vandalism for backflow prevention assemblies installed outside above ground. Freeze proof enclosures that meet or exceed state plumbing code standards are acceptable provided the insulation is at least 7.05 R factor, and have the 1060 ASSE approval plate. Adequate drainage shall be provided by hinged door drain or ports along the bottom walls of the protective enclosure. The enclosure will require to be mounted to the ground or existing grade. If the structure is not removable it must be accessible by doors large enough for entrance and repair. (j) Backflow prevention assemblies two and one-half (2½) inches or larger must be supported to allowed for the weight of the backflow prevention assembly. Support construction can consist of cinder block, brick or steel. Supports must have proper footing to rest on. Supports should be spaced so they do not cause interference with the testing and/or repair of the assemblies. (k) In order to prevent obstruction during the testing or repair of the assembly, additional piping and/or valves shall not be located within and/or under the enclosure. (l) All backflow prevention assembly installations shall be inspected by the city prior to initial connection to the potable water system. (m) Before installation of any backflow preventer, contact the city's public services department at (910) 938-5289 to assist in the proper selection and installation. (n) All reduced pressure (RP) principle assemblies must be installed in a horizontal position and in a location in which no portion of the assembly can become submerged in any substance under any circumstances (pit and/or below grade installations are prohibited). Double check valve assemblies may be installed in a vertical position with prior approval from the city provided the flow of water is in an upward direction or the assembly has been approved for this use by the Southern California's Foundation for Cross Connection Control and Hydraulic Research. (1) All existing commercial or high hazard commercial water services that are renewed shall have containment assemblies' installed at the service connection raised above ground in a freeze proof enclosure. (2) All facilities that change the intended use of the water supply shall install containment assemblies. (3) All existing facilities that change the name or are sold to new owners, are required to install a containment backflow assembly at the service connection on existing water services. (4) All outdoor above ground backflow assemblies are required to have an ASSE 1060 approved protective enclosure (in accordance with the state plumbing code, section 608.14.1). (o) All assemblies below ground that fail the annual test and are considered in a nuisance installation and are considered probable cause of a potential cross connection shall be raised above ground and placed in an ASSE 1060 approved freeze proof enclosure. (p) Assembly owners are responsible for the environment where assemblies are installed. Assembly owners are responsible for supplemental heat when assemblies are endangered of freezing. (q) Installation drawings shall be submitted to the city, before prior installation for upgrades to be approved by the city. (r) Assemblies below ground installed, that do not have working gravity drains and drains that are not two times the supply size of the water service supplying assemblies shall be raised and placed in an ASSE 1060 approved freeze proof enclosure. (s) The installation of a backflow prevention assembly, which is not approved, must be replaced with an approved backflow prevention assembly. (t) The installer is responsible to make sure a backflow prevention assembly is working properly upon installation and is required to furnish the following information to the city within fifteen (15) days after a reduced pressure principle backflow preventer (RP), double check valve assembly (DCVA), double check detector assembly(DCDA), or reduced pressure principle detector assembly (RPDA) is installed: (1) Service address where assembly is located; (2) Owner and mailing address; (3) Description of assembly's location; (4) Date of installation; (5) Installer (including name, company, license number, and project permit number); (6) Type of assembly, size of assembly; (7) Manufacturer, model number and serial number; (8) Test results, report. (u) When it is not possible to interrupt water service, provisions shall be made for a parallel installation of backflow prevention assemblies. The city will not accept an unapproved bypass around a backflow prevention device when the assembly is in need of testing, repair, or replacement.
(Ord. No. 08-29, 6-17-08; Ord. No. 09-69, 12-8-09)
Ask a question about Jacksonville law
Corpus searches the Jacksonville sections it holds and shows the ones that match, with their citations. Free, no sign-in.