§ 707 — Fire and life safety access
Code of Ordinances of the City of Rocky Mount, North Carolina (Codified through Ordinance No. O-2025-71, enacted November 10, 2025. (Supp. No. 90)) · Rocky Mount City Code § 707
Corpus is an independent public-information project, not the official City of Rocky Mount website. Stable reference: corpuslaw.us/code/b005db68-3869-41fc-afb1-8bccf515934b
Sec. 707. - Fire and life safety access.
The following standards for fire prevention, suppression, and access shall be met. A. Fire hydrants. 1. Fire hydrants shall be placed in approved locations every one thousand (1,000) feet in single-family residential or townhouse subdivisions in any district. Fire hydrants shall be located so that each front minimum building line is no more than five hundred (500) feet from a fire hydrant and located at street intersections, with intermediate hydrants between intersections, unless otherwise specified by the fire chief and director of public works. Where structures are located more that one hundred fifty (150) feet the frontal property line, the fire chief may require an additional fire hydrant(s). 2. Fire hydrants shall be placed every eight hundred (800) feet for non-residential or multi-family residential use. Fire Hydrants shall be located so that no part of any structure is more that four hundred (400) feet from a hydrant and located at street intersections, with intermediate hydrants between intersections, unless otherwise specified by the fire chief and director of public works. 3. Sprinklered building and/or buildings with standpipe systems shall have an additional fire hydrant designated for supporting that system. Fire hydrants designated for supporting those systems shall be located no more that seventy-five (75) feet from the Fire Department Connection (FDC). 4. The planning board and city council may require other spacing upon recommendation from the fire chief. All fire hydrant spacing shall be measured as road travel, not as crow flies. 5. All water lines sizes and fire hydrant locations and placement shall meet the latest NFPA standards; however, no fire hydrant shall be installed on a water line less than six (6) inches in size. For nonresidential subdivisions "The Guide for Determination of Required Fire Flow," as updated, published by the insurance services offices, will be utilized in determining the estimated water needs for fire protection. The minimal acceptable fire flow shall be one thousand (1,000) g.p.m. @ twenty (20) p.s.i., unless otherwise determined by the fire chief. B. Fire department connection locations. All FDC shall be located on the street side of buildings or in a vault. All FDC locations shall be approved by the fire department. C. Access. 1. Means of access for fire department apparatus to one (1) and two (2) family dwellings shall consist of approved fire lanes, private streets, public streets, parking lot lanes, or a combination thereof. Where structures are located more that one hundred fifty (150) feet from the frontal property line, the fire chief may require additional fire apparatus access roads. 2. Means of access for fire department apparatus shall be provided to all structures in planned building groups in accordance with this section and all applicable Fire and Building Codes. 3. Where access to an area is restricted because of secured openings or where immediate access is necessary for life saving or fire-fighting purposes, the fire department may require a Knox Box to be installed by the developer in an accessible location. 4. All public and private roadways shall be designed in accordance with the current city's engineering manual specifications, standards and designs manual. 5. Roadways shall conform to standards established in the city's subdivision regulations. 6. Parking in any means of access shall not be permitted within twenty (20) feet of a fire hydrant, sprinkler, or standpipe connection or in any other manner that will obstruct or interfere with the fire department's use of the hydrant or connection. 7. Fire lanes shall be provided and marked as required by the fire department fire lanes connecting to public streets, roadways, or private streets shall be provided with curb cuts extending at least two (2) feet beyond each edge of the fire lane. 8. Parking lot lanes shall have a minimum of twenty-five (25) feet clear width between rows of parked vehicles for vehicular access and movement. 9. Structures exceeding one thousand (1,000) square feet gross floor area shall not be set back more than fifty (50) feet from an approved fire lane or street. 10. Where traffic signals are required by Traffic Impact Analysis (TIA) or installed otherwise in normal or designated fire department access routes, the developer shall be responsible for the installation of Opticom or other traffic management devices as required by the fire department. D. Knox Box. The following structures shall be equipped with a Knox Box at or near the main entrance or other such location approved by the fire official: 1. Commercial or industrial structures protected by an automatic fire alarm system or automatic sprinkler or standpipe system, or such structures that are secured in a manner that restricts access during an emergency; 2. Commercial or multi-family residential structures that have restricted access or gated residential communities with limited access during an emergency.
(Ord. No. O-21-2, § 4, 1-11-21)
Ask a question about Rocky Mount law
Corpus searches the Rocky Mount sections it holds and shows the ones that match, with their citations. Free, no sign-in.