For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 712 — Site development plans

Code of Ordinances of the City of Rocky Mount, North Carolina (Codified through Ordinance No. O-2025-71, enacted November 10, 2025. (Supp. No. 90)) · Rocky Mount City Code § 712

Corpus is an independent public-information project, not the official City of Rocky Mount website. Stable reference: corpuslaw.us/code/374e01d2-1063-44b3-bf87-78cb712980df

Sec. 712. - Site development plans.

A. Purpose. Site plans are made a requirement for certain projects under this LDC in order to provide for planned and orderly development. The purpose of this section is to assure that the intent of the LDC is realized through a site plan review procedure and to allow a property owner to record development intentions for a specified period of time. B. Applicability and review classifications. Site development plans shall be required for all new development projects except single-family dwelling units or duplex units. The projects listed and described in subsections 1.—5. below shall be subject to the provisions of this section and shall require a site development plan: 1. General plan, Level I, Level II, Level III projects: a. General plans are defined as any plan review project involving commercial, small multi-family and/or industrial projects that are not required to meet the planning building group requirements of this LDC. Single-family and duplex residences are not included in this definition. Examples of general review projects include the following: 1) Residential projects containing three (3) or more attached dwelling units. 2) An expansion or modification of up to ten (10) percent in the floor area not to exceed ten thousand (10,000) square feet in an existing planned building group. 3) Any commercial project located within a MA, PDR, O-I, B-2, B-3, B-4, or B-5, zoning district involving one (1) or more buildings with total square footage not exceeding ten thousand (10,000) square feet for all building(s). 4) Any industrial project. b. General plan review projects will be placed into one (1) of three (3) levels for review depending on complexity of the proposed development. 1) Level I projects are small additions, up to one thousand (1,000) square feet in area, that do not require any additional site work except for the building construction. Level I projects must submit plans meeting only the minimum submittal requirements. Level I general plans are reviewed and may be approved by the director or the director's designee. 2) Level II projects are all nonresidential projects, greater than one thousand (1,000) square feet and less than ten thousand (10,000) square feet and multi-family projects containing three (3) to eight (8) units that require additional site improvements such as additional parking, water and sewer main extensions and/or drainage improvements. Level II projects must submit plans meeting the minimum submittal requirements and the other information required to evaluate the proposed improvements for compliance with city codes and standards. Level II general plans are reviewed and approved by the DRC. 3) Level III projects include any industrial project located in an I-1, I-2 or I-P zoning district, regardless of the size of the project. Level III projects must meet the criteria for Level II and obtain a wastewater discharge permit when required by the city engineer. Level III general plans are reviewed and approved by the DRC. Areas that are visible from the public right-of-way and that are accessible to the public shall be required to comply with the paving and landscaping requirements as established in chapter 7 of this LDC, however, all other areas are exempt from said requirements. 2. A planned building group project is defined as: a. A residential project containing nine (9) or more attached dwelling units (e.g. apartments); b. A residential project with attached dwelling units for individual ownership (e.g. townhouses); c. A commercial and/or office-institutional project located within a PDR, MA, O-I, B-1, B-2, B-4 or B-5 zoning district involving the construction of one (1) or more buildings containing a combined total of ten thousand (10,000) square feet or greater; d. A commercial and/or office-institutional project within a PDR, MA, O-I, B-1,B-2, B-4 or B-5 zoning district involving the construction of three (3) or more buildings regardless of project size; e. A commercial and/or office-institutional project located within a B-3 zoning district, regardless of project size and building number; f. A formerly approved non-planned building group project for which new structures are added to the site and/or the cumulative addition of ten thousand (10,000) square feet or greater is obtained on the site. g. Institutional uses such as childcare centers, churches, schools, and similar institutional uses, regardless of the zoning district, involving the construction of one (1) or more building containing a combined total of ten thousand (10,000) square feet gross floor area or greater; h. A commercial and/or office-institutional project within a B-2 or B-5 zoning district located within the Central City area; i. A college or university; j. A manufactured home park. Planned building group projects may be approved by the planning board upon recommendation of the DRC. 3. Residential and commercial cluster development projects. (See section 712D.5.) 4. Planned density residential (PDR) projects: (See section 712D.4.) 5. Other new development projects: The following projects are subject to the requirements of this section and may be approved by the DRC. a. Construction of a building or alterations or expansions to an existing building or use of a property. b. Construction of, or changes to, parking areas, circulation, access points, or other site improvements. Resurfacing that changes or deviates from the originally approved design is also included for consideration under these provisions. c. Alterations of watercourses, watershed boundaries, water bodies, or flood plain boundaries. d. Changes of land or building use where revisions to landscaping or buffering standards apply. C. Criteria for approval. The following evaluations shall be made during site plan review. Site plans that do not meet the criteria identified below shall be rejected. a. Compliance with all applicable LDC and other applicable code requirements. b. Compliance with a previously approved plan, such as a development plan or the city's comprehensive plan. c. Locations and adequacy of pedestrian and vehicular access points and parking areas. d. Design of traffic patterns, traffic control measures and street pavement areas, with provisions for maintaining traffic flows and reducing unfavorable effects of traffic on nearby properties. e. Compliance with landscaping standards and site construction specifications. f. Adequacy of stormwater drainage, water supply, sewer service, fire protection, street signs, and street lighting. g. Compliance with requirements for easements or dedications. h. Conformance with open space and trails planning. i. Solid waste regulations. D. Required contents for site plans. Site plan documents shall contain, the information listed below unless the DRC determines that less detailed information is required for adequate review. No process or review of a site plan will proceed without the required information. Detailed standards and specifications for design and construction are available from city, county and state agencies, as applicable. 1. Plan review site plan requirements, Level I. All Level I plans submitted for general plan review must include these minimum submittal requirements: a. Plan must show the following information. The scale on the plan should be such that the relevant features of the project can easily be determined (minimum of 11" by 17" paper). Multiple sheets may be submitted when needed for clarity. 1) Vicinity map including North arrow. 2) Property identification number (PIN). 3) Map of property being developed including North arrow if different from vicinity map. 4) Existing property boundaries including metes and bounds and lengths. 5) Building footprint and elevations. 6) Setbacks from property lines: building and arterial (if applicable). 7) Location of all easements and rights-of-way. 8) Floodplain or watershed protection area boundaries (if applicable). 9) Title block with project name and location, drawing scale, names of engineer and/or surveyor if appropriate, and developer or property owner and date of drawing. b. Zoning and land use information: 1) Current zoning designation and existing or proposed land use for the subject property. 2) Current zoning designation and land use of adjoining property owners. 3) Size and location of any existing or proposed signs. c. Existing and proposed improvements: 1) A clear delineation between existing and proposed improvements such as crosshatching for existing areas or other method showing the difference between existing and proposed. 2) On site and adjacent storm drainage structures including pipes, ditches and catch basins. 3) Proposed and existing streets including street names and current or proposed street address. 4) All utilities (water, sewer, gas and electric) including meter location(s). 5) Current or proposed type of solid waste collection and dumpster pad if applicable. (Contact the public works department for determination of type of collection required). 6) Existing and proposed parking area including number of existing and required spaces, parking area dimensions and type of surface. For surfaces other than asphalt or concrete, parking bumpers must be shown. 7) Location of loading areas for commercial projects. 8) Location and width of driveways. 9) Locations and square footage of all existing and proposed building(s). 10) Total area that will be disturbed during the construction. 11) Upon review by the development review committee, some projects may be reclassified to a higher level due to additional on site improvements that may be required. 12) [Reserved.] 2. Plan review site plan requirements, Level II & III. All Level II and III plans submitted for plan review must include the minimum submittal requirements above and the following where applicable: a. Department of development services requirements. 1) Lighting plan inclusive of wattage and illumination. 2) Number of units and bedrooms per unit, (residential projects only). 3) Landscaping plan including calculations and details including location and height of all fences, walls and plants shown with a parking landscape radius detail. (Checklist available from planning dept.) 4) Base flood elevation (BFE) and lowest floor elevation for projects located within the floodplain. 5) Density or built upon area and calculations for those projects located in the watershed. 6) For projects requiring a new or relocated bulk solid waste collection container, show the location and details of bulk solid waste container pad and screen. (Contact public works department for requirements). b. Erosion and sediment control requirements. For sites one (1) acre of disturbed area or larger: 1) A completed and notarized financial responsibility form. 2) Location and size of temporary swales, berms and diversion ditches. 3) Location and size of sediment traps, temporary rock check dams and stabilized gravel construction entrance. 4) Methods of permanent ground stabilization (grassing, landscaping), location of temporary silt fences and details on catch basin protection. 5) If retention/detention basin is required, a detailed design including emergency spillway and outlet design must be provided. 6) The following notes must be shown on the plans: a) A permit from the city and NC DENR as appropriate is required prior to construction. b) The erosion control measures must be maintained in good working order until final inspection and approval of the project by the city. c) Any grading beyond the limits of the approved plan is in violation of the city LDC and is subject to a fine. c. Storm drainage requirements. 1) Show existing drainage on the site and the total amount of impervious surface area such as parking lots and building(s) that will be added as a result of the project. 2) Show direction of drainage and topography of the site at contour intervals no greater than two (2) feet. 3) Provide all design calculations for the proposed storm drainage system: a) Design storm event for various types of pipes. b) Design storm velocities in all pipe sections, swales and ditch sections. c) Pre and post development run off calculations and drainage area maps including any off site drainage that may be impacted by this project. d) Provide plans showing the location, size, invert, grade, rim or grate elevations and type of pipe for all proposed and existing storm drainage pipe, culverts, ditches, catch basins, drop inlets and manholes. e) Show the location and width of all storm drainage easements and indicate if they are to be public or private easements. f) Provide details of all drainage structures to be used. g) Location of floodway and floodplain within project boundaries. h) For all ditches, the side slope grades must be shown. (The maximum side slope shall be dependent upon the soil type and/or the type of stabilization proposed). i) If the proposed storm drainage system connects into an existing pipe or ditch, the existing flow in the pipe at the design storm events must be calculated and the ability of the pipe to handle the additional flow demonstrated. j) Existing and proposed contours (all elevations should be based upon NGVD). k) Design details and calculations for stormwater management and/or other BMP's to be constructed. l) Sanitary sewer requirements. These requirements apply only if a public sewer main is required to be installed. Provide all design calculations for the proposed sewer system to include minimum and maximum velocities in all pipe sections or projects. 3. Planned building group regulations. Before submitting a construction plan for a planned building group it is recommended that a preliminary plan be submitted, in an effort to minimize development costs, avoid misunderstanding or misinterpretation, and ensure compliance with the requirements of this section. However, the applicant may choose to omit the preliminary plan process and submit a construction plan. a. Submission and review of planned building group preliminary plan. All planned building group preliminary plans submitted for plan review must include the minimum submittal requirements listed below. The number of sets of plans as established in the city's administrative manual shall be submitted. The DRC shall review the plans for compliance with the standards of this LDC and other city requirements and shall forward a recommendation to the planning board for consideration. 1) Proposed name of the subdivision and proposed names of any public streets. 2) Parcel information including tax parcel identification (PIN), metes and bounds of property, lot size, current zoning including any conditional uses, adjoining street names, names of adjoining property owners and adjacent zoning. 3) Vicinity map location streets and highways, sections lines, railroads, schools, parks, and other significant features within one-half (½) mile of the proposed subdivision. 4) Contour intervals to sea level datum of not more than two (2) feet when the slope is less than four (4) percent, and not more than five (5) feet when the slope is greater than four (4) percent, referenced to a United States Geological Survey or Coast and Geodesic Survey bench mark or monument. 5) Natural features within and surrounding the proposed subdivision including streams, drainage channels, bodies of water, wooded areas and other significant natural features. On all watercourses leaving the tract, the direction of flow shall be indicated, and for all watercourses entering the tract, the drainage area below the point of entry shall be noted. 6) Man-made and other cultural features within and surrounding the proposed subdivision, including existing and platted streets, bridges, culverts, utility lines, pipe lines, power transmission line structures, all easements, park areas, city and county lines, and other significant information. 7) Proposed project layout, including building footprint, required parking and loading bay, building setbacks, plan view of proposed water and sewer service, location of required landscaping including perimeter buffers and interior islands. 8) Location of curb and gutter along major and minor arterial, collector and local streets constructed with curb and gutter. 9) Proposed location and types of solid waste storage facilities. 10) Conceptual drainage plan including size and location of stormwater management facilities and pipes and plan view and cross sections of any on site or off site ditches carrying stormwater. 11) Proposed finish floor elevation of the building, base flood elevation and floodway if appropriate. 12) If a traffic impact analysis is required for the project, submit copy of TIA and show in plan view all recommended improvements. 13) Such other information as the subdivider wishes to bring to the attention of the planning board and the city. 14) Technical documentation. The preliminary plat submitted shall also be accompanied by the following written information: 15) Source of water supply and distribution. 16) Horizontal alignment for sanitary sewer, water supply, drainage and flood control. 17) Typical cross sections of all streets. 18) Certifications and endorsements: Certification by the Director of Development Services and the Director of Public Works that this Planned Building Group Preliminary Plan was approved by the Planning Board on ________ (date) and meets the standards set forth in the Land Development Code. _____ | _____ Director of Public Works | Director of Development Services b. Submission and review of planned building group construction plan. All planned building group construction plans submitted for plan review must include the minimum submittal requirements in subsection D.1. and D.2. above and the following where applicable: 1) Proposed provision for storm drainage and sanitary sewerage, approved by the director of public works. 2) Topography of site at contour intervals of no greater than two (2) feet. 3) Size and proposed location of any signs (including business identification, traffic control/parking and handicap). An integrated sign system design shall be required for all planned building group developments. These systems shall be reviewed by the director of development services or designee for materials, colors, shapes, sizes, compatibility with architecture and unity of design for the development. New individual signs and changes to existing individual signs shall be reviewed for conformance with such sign systems. 4) All planned building groups shall meet the minimum provisions of the zoning district in which they are to be constructed with respect to the following: a) Minimum lot area b) Parking c) Landscaping 5) Where any non-residentially zoned planned building group abuts a residential zoning district, such plan may include one (1) or more of following: a) existing or new berms of a reasonable height, b) additional decorative landscaping or opaque fencing, c) permanent undisturbed buffers and setbacks. 6) Proposed solid waste storage facilities: Either mechanically dumped bulk containers compatible with and accessible to city is required. The location and design details of bulk container must be shown on project site plans and be approved by the director of public works or representative. Projects shall be designed and constructed to city standards and specifications. Consideration or proposed use of a private collection service does not negate this design requirement and any modification after plan approval must be approved by the director of public works or representative. 7) All hydrants must be served by a water main of sufficient size. In no case shall the minimum size main be less than six (6) inches in diameter. 8) Fire department vehicular access to all structures under construction shall be provided at all times. In areas where ground surfaces are soft or likely to become soft, hard all weather surface roads shall be provided. 9) Where the length of a dead-end private drive for residential uses exceeds three hundred (300) feet and where a dead-end private drive serves non-residential uses exceeds on hundred fifty (150) feet, an area must be provided for the turnaround of firefighting vehicles on a paved or graveled surface. This area shall not be used for parking and shall subscribe a circular area having a radius of forty-five (45) feet or, shall have a configuration which provides comparable turnaround space. 10) At least fourteen (14) feet of nominal overhead clearance shall be provided over the full width of streets, private streets, fire lanes, and other means of vehicular access. 11) The fire protection water supply system, including fire hydrants, shall be installed and in service prior to recording the subdivision; or if no subdivision is involved, the placing of combustible building materials for structures, or combustible pre-tested fabricated building assemblies on the project site or utilizing them in the construction of building structures. If phased construction is planned, coordinated installation of the fire protection water system is permitted. 12) Types of surfacing, slope, grade and cross-section of drives and sidewalks. 13) The location and heights of all fences, walls and hedges shall be shown. 14) Profiles of publicly maintained water and sewer lines. 15) Profiles, cross sections and slopes of on-site and off-site ditches carrying water runoff. 16) Erosion and sedimentation control plan. 17) The installation of curb and gutter shall be required for parking lots. This may be waived or modified by the planning board upon recommendation of the director of public works if storm drainage, traffic circulation and other site design issues are improved by such waiver. 18) Depict traffic-control devices. 19) All plans and construction details must meet the current specifications of the city. 20) Location and size of all heating, ventilation, air conditioning, and refrigeration equipment to be located outside the exterior building wall. 21) Timing: Proposed schedule of development including stages likely to be followed. 22) In addition to the requirements set forth in subsequent subsections of these planned building group regulations, a traffic impact analysis (TIA) prepared in accordance with city guidelines (available from the department of public works) shall be required for any planned building group that satisfies either one (1) of the following criteria: a) The proposed development is located reasonably proximal or adjacent to one (1) of the corridors identified in Table 7-1 and is expected to generate more than one hundred (100) additional peak hour trips (a.m. or p.m. peak) or one thousand (1,000) additional daily trips as determined by the most current edition of the ITE Trip Generation Manual. b) The proposed development is expected to generate more than four hundred (400) peak hour trips (a.m. or p.m. peak) or four thousand five hundred (4,500) daily trips as determined by the most current edition of the ITE Trip Generation Manual. c) This work shall be completed by a North Carolina registered professional engineer based on a scope of work approved by the city traffic engineer or designee prior to submittal of the project to the development review committee. d) The submittal of the TIA does not release the applicant from having to amend the analysis to address any substantive changes that result from the development review committee. Guidelines addressing the preparation of the traffic impact analysis will be made available by the city's department of public works. Table 7-8. Corridors Identified for Application of ITE Traffic Impact Analysis Thresholds. Roadway | From | To Wesleyan Boulevard | Bethlehem Road | Jeffreys Road Sunset Avenue | Halifax Road | River Drive Winstead Avenue | Bethlehem Road | Hunter Hill Road Benvenue Road | Peele Road | Hunter Hill Road Jeffreys Road | Country Club Road | US 301 Raleigh Rd/North Raleigh St | US 301 Bypass | US 64 Bypass Hunter Hill Road | Winstead Avenue | Benvenue Road 23) All Planned Building Groups are required to include the following municipal certification on each page of the approved construction improvement plans: Certification by the Director of Development Services and the Director of Public Works that this planned building group construction plan conforms to the preliminary plan approved by the Development Review Committee on _______ (date) and meets the standards set forth in the Land Development Code. _____ | _____ Director of Public Works | Director of Development Services 24) No construction may begin on the improvements required by this LDC until the planning board has approved the plans for those improvements and the plans duly signed by the director and director of public works. Any party who initiates construction without an approved plan may be subject to the fines and penalties outlined in chapter 12, "Specific Penalties". 25) The development review committee may approve an expansion and/or modification of up to ten (10) percent in the floor area not to exceed ten thousand (10,000) square feet, the parking area and/or other improvements of an existing or approved planned building group project. The proposed expansion and/or modification shall be shown on the planned building group plan previously approved by the planning board. In approving the proposed expansion and/or modification, the development review committee shall ensure that the project: a) Meets applicable LDC and other code requirements. b) Has adequate provisions for drainage. c) Has adequate traffic circulation. d) Has adequate fire protection. e) Has adequate solid waste collection facilities. Upon satisfying the above standards, the proposed expansion and/or modification shall be approved by the DRC. Any project not approved by the DRC may be presented to the planning board for consideration of the standards specified herein. 26) Placement of buildings: a) There shall be maintained at least twenty (20) linear feet of open space between individual and unattached buildings in a residential planned building group. b) Any group of buildings forming a courtyard shall have at least twenty-five (25) percent of the perimeter of such courtyard open for access by Emergency vehicles. c) Where the length of a street exceeds three hundred (300) feet and where there exists three (3) or more dwelling units, an area must be provided for the turnaround of firefighting vehicles on a paved or graveled surface. This area shall not be used for parking and shall subscribe a circular area having a radius of thirty-five (35) feet or, shall have a configuration which provides comparable turnaround space. 27) Specifically for apartment and condominium projects—Recreation area: Play areas shall be provided for all apartment and condominium planned building groups. A minimum play area of two thousand (2,000) square feet, having a minimum width of forty (40) feet or a minimum radius of twenty-six (26) feet shall be provided for the first six (6) to twenty-five (25) dwelling units. For each dwelling unit over twenty-five (25) in number an additional fifty-six (56) feet per dwelling unit shall be provided. The spatial distribution and number of individual play areas within the planned building group shall be determined by the planning board on the basis of the special arrangement of the dwelling units, topography and other physical features. Swimming pools and their accessory areas shall not constitute any part of the open space requirements. No part of the required play area shall be used for any other purpose. 28) Specifically for projects with attached units for individual ownership. (Condominium/Townhouse) a) Minimum lot area. Seven thousand (7,000) square feet for the first two (2) dwelling units of each building; one thousand eight hundred (1,800) square feet for each additional dwelling unit of each building. Individual lots shall be exclusive of any public land or street right-of-way. In no case shall the number of dwelling units exceed sixteen (16) per acre, exclusive of any streets or publicly dedicated land. It is noted that the planning board may recommend, and the city council may require, a lower dwelling unit density per acre than the density specified by the minimum lot area due to factors such as, but not limited to, traffic congestion, projected demands on community facilities, availability of water, sewer and electrical utilities, and consistency with the comprehensive plan of the city. b) Minimum lot width. Fourteen (14) feet. c) Maximum number of dwelling units per building. Eight (8). d) Setbacks. i. All dwelling units must be setback a minimum of twenty-five (25) feet from a public street and a minimum of twenty (20) feet from the initial perimeter of the subject development. ii. All buildings must be separated by a minimum of twenty (20) feet. e) Access. All lots shall front on a public street unless a homeowner's association is established in accordance with the provisions of this LDC and each lot is provided direct access to a public street across common property perpetually maintained for such purposes. A five (5) foot pedestrian, drainage and utility easement shall be provided on each lot along the entire length of all rear lot lines and side lot lines which are situated between the end walls of buildings. No fences, trees, shrubbery or other similar obstructions shall be permitted in that five (5) foot pedestrian, drainage and utilities easement. f) Structures. Location and approximate size of all existing and proposed buildings and structures within the site and all existing buildings and structures within one hundred (100) feet, in addition to public or private easements or rights-of-way adjoining or intersecting such property. g) Circulation. Proposed points of ingress and egress and proposed pattern of internal automobile and pedestrian circulation. 29) Specifically for manufactured home parks. a) All manufactured home parks existing on the effective date of this LDC are required to comply with all applicable procedures and requirements of this LDC. Any manufactured home park failing to comply with the applicable provisions of this LDC is hereby declared to be a nonconforming use of land. All manufactured home parks shall continuously comply with the general requirements of this LDC. Failure to meet continuously each of the general requirements shall be grounds for revocation of the certificate of occupancy/compliance. This provision does not require a manufactured home park which was approved prior to adoption of this LDC to locate units with a parallel orientation to the lot (or approved space) frontage. b) Minimum lot area. The minimum area of ten (10) acres, providing for a minimum of twenty-five (25) manufactured home spaces shall be mandatory for the establishing of a manufactured home park. Individual manufactured home spaces shall be at least fifty (50) feet in width and shall contain at least five thousand (5,000) square feet of area. In addition, a park shall have sufficient area to meet all applicable planned building group requirements. c) Permitted manufactured homes. Manufactured homes meeting the definition for Type A, A-1, B or C may be permitted. Type D units shall be prohibited. d) Density. A maximum of six (6) units per acre shall be permitted. e) Parking: Each manufactured home space shall be provided with a driveway sufficient to accommodate two (2) vehicles parked in tandem. A waiver may be granted by the planning board during the planned building group process if an alternate parking design is determined to be appropriate. All parking areas, including those on individual manufactured home spaces, shall be hard-surface material approved by the department of public works. f) Screening and fencing. Manufactured home parks shall have on their entire perimeter a thirty (30) foot wide, Type D landscaped buffer as defined in chapter 7 of this LDC. This buffer shall be unbroken except at park entrance driveways or walkways. For a park that shares a property line with an existing park that already has a conforming bufferyard, the planning board may reduce the proposed bufferyard by up to fifty (50) percent. For parks located adjacent to railroads, major arterials, or other potential hazards, a suitable barrier shall be provided to ensure safety, and this shall be in addition to the required buffer. Screening of dumpsters is required, if applicable. g) Structures. Location and approximate size of all existing and proposed buildings and structures within the site and all existing buildings and structures within three hundred (300) feet, in addition to public or private easements or rights-of-way adjoining or intersecting such property. This requirement shall include the location of all intended carports, garages, outside storage buildings, etc. Plans must indicate the type of manufactured home to be placed on each space (Type A, A-1, B, and C) and how the unit is to be oriented. A waiver of the parallel orientation requirement for Type A, A-1, and B units (as provided for in the definitions) may be approved by the planning board and so indicated on the plan. A space designated for a Type C unit may be used for a Type C, B, A-1 or A unit. A space designated for a Type B unit may be used for a Type B, Type A-1 or a Type A unit. A space designated for a Type A-1 unit may be used for a Type A-1 or a Type A unit. h) Circulation. Proposed points of ingress and egress and pattern of internal circulation. All manufactured home spaces shall abut an interior drive or street. No manufactured home space shall have an individual driveway access through the required bufferyard to a public or private street. i) Landscaping: As specified in chapter 7 of this LDC and additional requirements as noted in this section. j) Location and dimensions of individual manufactured home spaces. Each space must designate a specific type of home permitted (A, A-1, B or C). k) Provision for storm drainage and a sedimentation and erosion control plan. l) Location and size of open play spaces and all other accessory features customarily incidental to the operation of a manufactured home park. m) There shall be a yard clearance of at least fifteen (15) feet between each manufactured home, including manufactured homes parked end-to-end. Manufactured homes or accessory structures shall be located no closer than thirty (30) feet to any exterior property line of the park, and no closer than ten (10) feet to the edge of any interior street or walkway. n) All manufactured home parks must connect to public water and sewer services. If the internal water and sewer lines are intended to be maintained by the city and/or if meters are to be provided by the city at individual home spaces, all lines shall be constructed to city standards and main lines located either within a publicly dedicated right-of-way or a publicly dedicated easement located outside any interior drive. Service lines from the tap to the individual meter may not be located outside of the dedicated right-of-way or easement. If water lines within the park are not public, the park must be served with a master meter. o) In addition to the yard area provided on each manufactured home space, at least two hundred (200) square feet of recreation area per manufactured home space shall be provided. Recreation areas shall be designed to meet the needs of the anticipated population of the manufactured home park and shall at a minimum include all of the following: i. A play lot for preschool children containing a minimum of twelve hundred (1,200) square feet within five hundred (500) feet of every space, improved with appropriate play equipment. The planning board may reduce the required recreational facilities for children if the park is to be restricted to adult occupancy only. ii. One (1) or more recreation areas for school age children and adults, provided with appropriate equipment for both active and passive recreation. iii. No recreation area shall be located within a power line easement, floodway, or other area not suitable for such purposes. p) All interior streets must meet city standards for either private or public streets. Private streets shall be defined for this purpose as in Table 25 private street requirements, and having the same right-of-way and construction width as a "private street" for a PDR and cluster developments. Walkways constructed of all-weather surfaces shall be provided as needed. q) All homes located within a manufactured home park must have a continuous masonry foundation, masonry curtain wall or skirting (as appropriate for the specific type of unit) installed prior to issuance of certificate of occupancy. The foundation, curtain wall or skirting shall be un-pierced except for required ventilation and access. Where skirting is used, it must be made of material designed and/or adapted for specific use as manufactured home skirting. r) In manufactured home parks, fire hydrants shall be located at entranceways and street intersections, with intermediate hydrants between intersections, but in no case shall there exceed more than one thousand (1,000) feet between fire hydrants, unless otherwise specified by the fire chief and director of public works. In addition: s) Fire department vehicular access to all structures under construction shall be provided at all times. In areas where ground surfaces are soft or likely to become soft, hard all weather surface roads shall be provided. t) All hydrants must be served by a water main of sufficient size. In no case shall the minimum size main be less than six (6) inches in diameter. u) At least fourteen (14) feet of vertical clearance shall be provided over the full width of streets, private streets, fire lanes, and other means of water system is permitted. v) Lighting shall be provided throughout the park to ensure safety of vehicles and pedestrians. All telephone, cable TV and electric lines shall be located underground. Lighting plans shall be approved by the city. w) All structural additions to manufactured homes, other than those which are built into the unit and designed to fold out or extend from it, shall be erected only after a building permit shall have been obtained, and such additions shall conform to the building code of the city, where applicable, or shall meet the standards of any special regulations adopted with respect to such additions. The certificate of occupancy/compliance shall specify whether such structural addition may remain permanently, must be removed when the manufactured home is removed or must be removed within a specified length of time, not to exceed three (3) months, after the manufactured home is removed. x) Solid waste storage facilities: Mechanically dumped bulk containers (dumpsters) compatible with and accessible to city equipment are required. The location and design details of bulk container sites must be shown on project site plans and be approved by the director of public works or representative. Projects shall be designed and constructed to city standards and specifications. Dumpster sites shall be screened from view of adjacent residential spaces or residential lots. Screening may be accomplished by a closed fence or wall which is at least the height of the dumpster. y) The fire protection water supply system, including fire hydrants, shall be installed and in service prior to approval of the manufactured home park; placing of combustible building materials for structures, or combustible pretested fabricated building assemblies on the project site or utilizing them in the construction of building structures. If phased construction is planned, coordinated installation of the fire protection. z) Consideration or proposed use of a private collection service does not negate this design requirement and any modification after plan approval must be approved by the director of public works or representative. Planned sites need not be screened until developed for use with dumpsters. aa) Manufactured home parks with publicly dedicated interior street systems may be eligible for rollout cart service, with the approval of the director of public works or representative. 30) Specifically for business projects. a) The following planned building group development shall apply in the development of a B-3 zoned property, regardless of project size. In addition, projects located within PDR, MA, O-I, B-1, B-2, B-4, B-5, districts and churches and schools in any zoning district involving the construction of a building greater than ten thousand (10,000) square feet or projects involving the construction of more than one (1) building, structure or combination thereof shall also comply with the following regulations. Relative to expansion of a building and site improvements not qualifying for hereinafter identified "exceptions," existing building(s) and existing supporting on-site improvements such as, but not limited to, parking spaces, landscaped areas, etc. are not required to meet planned building group provisions. Proposed building and on-site improvements (non-exception) construction shall be developed according to these business planned building group provisions. b) Screening and fencing. A screen not less than six (6) feet high of dense plant material and/or fence where the lot abuts a residential lot. c) Lots fronting on a public street. The planning board may approve plans with lots within the interior of a business planned building group project provided that the board finds that adequate access is assured by the design of the planned building group. d) Minimum yard requirements. The planning board may approve plans which do not provide minimum yards along interior lot lines within a business planned building group project. All exterior lot lines located along the perimeter of the business planned building group shall satisfy the standards listed within the "district dimensional standards." e) Curb and gutter. The installation of curb and gutter shall be required as well as pavement as specified herein. The addition of curb and gutter may be waived or modified by the planning board upon recommendation of the director of public works, if storm drainage, traffic circulation or other site design issues are improved by such waiver. f) Plans are required and must show: g) Structures: Location and approximate size of all existing and proposed structures within the site and all buildings and structures within five hundred (500) feet, in addition to public or private easements or rights-of-way adjoining or intersecting such property. h) Circulation: Proposed points of access and egress and proposed pattern of internal automobile and pedestrian circulation. i) Parking and loading: Location and extent of proposed parking and loading areas. j) Points of access and egress shall consist of driveways or roadways at least twenty (20) feet in width and shall be set back a sufficient distance from highway intersections to minimize traffic hazards, inconvenience and congestion. k) Parking areas shall have a stabilized surface with parking spaces and traffic lanes clearly marked. 31) Specifically for central city projects. a) The following planned building group regulations shall apply to all new construction or expansions of existing buildings in B-5 or B-2 zoned property located within the central city area. These requirements shall be in effect for both the development of individual buildings over ten thousand (10,000) square feet, and two (2) or more buildings on a single parcel, the combined area of which is greater than ten thousand (10,000) square feet. b) Screening and fencing. A screen not less than six (6) feet high of dense plant material and/or fence where a lot abuts a residentially zoned lot, to include the O-I zone. c) Plans are required and must show: d) Structures: Location and approximate size of all structures. e) Circulation. Proposed points of access and egress and proposed pattern of internal automobile and pedestrian circulation. Curb cuts at a maximum combined width of twenty-five (25) feet shall be allowed for each eighty (80) feet of lot frontage or portion thereof. The locations of all points of ingress and egress shall be approved by the city planning board upon recommendation by the city's traffic engineer. f) Signs: The applicable sign regulations shall apply to this planned building group requirement. 32) Specifically for college or university projects. a) Plans shall show: b) Minimum project and lot area. All college and university planned building group projects shall contain a minimum of three (3) acres. c) Parking and loading. See section 707. d) Loading bays. One (1) loading bay for each thirty thousand (30,000) square feet of administrative space and one (1) loading space for the school cafeteria. e) Minimum yard requirements. All exterior lot lines within a college or university planned building group shall satisfy the standards listed within the Table 6 "yard and area requirements." In addition, a minimum seventy-five (75) foot setback will be required for any yard that abuts residential development. f) Structures: Location and approximate size of all existing and proposed structures within the site and all buildings and structures within five hundred (500) feet, in addition to public or private easements or rights-of-way adjoining or intersecting such property. g) Circulation: Proposed points of access and egress and proposed pattern of internal automobile and pedestrian circulation. h) Points of access and egress shall consist of driveways or roadways at least twenty (20) feet in width and shall be set back a sufficient distance from highway intersections to minimize traffic hazards, inconvenience and congestion. i) Parking area shall have a stabilized surface with parking spaces and traffic lanes clearly marked with the exception of athletic facilities. j) College or university identification sign location and specifications. Sign size shall be as approved by the planning board. 33) Specifically for O-I(2) projects. a) Proposed project shall be a combination of two (2) of the following land uses: commercial, residential or office. Stand alone develop of any one shall not be permitted. No one (1) land use (commercial, residential or office) shall be greater than seventy-five (75) percent of the total development. b) Project shall contain a minimum of two (2) acres. c) A fence not less than six (6) feet must be used in addition to all buffer requirements (reduction in width is prohibited). d) Signs: The applicable sign regulations shall apply to this planned building group requirement. e) Parking: When commercial and office uses are proposed together, parking calculations will be based solely on commercial uses. 4. Planned density residential districts (PDR). The district is intended to encourage efficient use of the land and public services and to promote high quality design that will provide a variety of dwelling types as well as adequate support services and open space for the residents of the development. The district regulations are intended to allow innovative development that is integrated with proposed adjacent uses and compatible with existing patterns of development. a. Pre-application conference recommended. Before submitting an application for a rezoning to the PDR district, the applicant may confer with the DRC in order to become familiar with these district review processes. The DRC will inform the applicant of the information required for filing the application. At the pre-application conference, the applicant shall provide the following: 1) Boundaries of the property involved; 2) Existing roadways, easements, flood zone boundary lines, watershed boundary lines and waterways; 3) A general plan of development at a level of detail sufficient to indicate the nature and scope of the project including its magnitude in terms of approximate number and types of dwelling units, location and extent of nonresidential elements, proposed locations of major open space areas, and major circulation facilities; and 4) Proposed treatment of the perimeter of the project boundaries bordering other zoning districts, i.e. buffer yards, setbacks, etc. b. Application. Following the pre-application conference, the applicant may proceed in preparing a formal application for a PDR development. The application shall consist of a simultaneous submission of a rezoning request, a special use permit application, a preliminary plat (when required) and proposed site development plan in accordance with chapter 7 of this LDC. Applications shall be accompanied by a nonrefundable fee, proof of ownership or statement from property owner authorizing application. c. Development plan required. No building permits or other permits regulated by this LDC shall be issued on land within any PDR district except in accordance with the approved development plan. The developer shall submit a master plan showing the conceptual design of the proposed development and a written instrument describing the conditions for the development. Including but not limited to density, setbacks and dwelling unit type, etc. d. Master plan submittal. The master plan shall include the following: 1) A legal survey of the property (with metes and bounds). 2) Parcel identification number (PIN). 3) General location, square footage, density (units per acre), height and description of all buildings and uses with proposed setback lines. 4) Proposed vehicular circulation and pedestrian circulation. 5) Storm-water drainage plan, if required. 6) Landscaping plan, required buffer yard(s), and proposed maintenance provisions. 7) Gross area, lot area, and open space calculated to the nearest tenth of an acre. 8) Delineation of any proposed construction phasing of the proposed development. 9) Right-of-way, easements, and utility locations. 10) Indication of existing natural features of the property, including watercourses, floodplain boundary lines with zones, watershed protection boundary lines, unique natural features and vegetation. 11) Notes to plan: Include the name of the development; flood map and panel number; tax parcel identification number (PIN); name and address of property owner;, name and address of developer; name, address and telephone number of project engineer and/or designer; name, address and telephone number of contact person for project; zoning district with any conditions of approval. 12) Other information deemed necessary by the DRC and director of development services. e. PDR district requirements. The following requirements shall be met by any proposed PDR rezoning application. 1) The maintenance and perpetual existence of required private open spaces, easements, and right-of-way shall be guaranteed by creation of entities and the imposition or real conditions, covenants and restrictions as required by the city council. 2) See section 713 of this LDC for regulations relative to homeowners associations. 3) In the event that a subdivision plat is not required for approval of the entire PDR, no building permit for any structure within the development shall be granted until conveyances for any required public easements, streets, rights-of-way, or other public areas shall have been accepted by the city and filed with the appropriate county. 4) Where public improvements are to be constructed or where improvements are to be made upon lands to be conveyed to the city, the landowner shall, in accordance with approved construction plans, execute the required improvements and obtain the proper inspections, or provide a financial guarantee approved by the city to cover cost of the required improvements prior to obtaining any building permit within the development. 5) Privately maintained alleys may only be permitted in neo-traditional, new urbanism or smart growth developments within the PDR districts at the rear of lots to be used for business and residential purposes when constructed to city standards and where easements are included for necessary utility and trash pick-up purposes and maintenance is provided for in Homeowners Association documents. 6) The minimum lots size for residential lots shall be thirty-five hundred (3,500) square feet. 7) Where residential garages are accessed from a private alley, the rear yard set back shall be a minimum of eighteen (18) feet from the private alley easement line. 8) Where any PDR district abuts a residential zoning district, the planning board shall require such plan to maintain or otherwise provide one (1) or more of the following: 9) Existing or new berms of a reasonable height, 10) Additional decorative landscaping or opaque fencing, 11) Permanent undisturbed buffers and setbacks. 12) Density requirements: a) The specific density in units per gross acre must be included in the application. The maximum allowable density is as follows: Density specified in the approval is the maximum allowable density, however, a PDR development shall not exceed ten (10) units per gross acre maximum. 13) Dimensional requirements: a) Fifty (50) contiguous acres minimum; b) Addition to an existing approved PDR district may be made in increments of any size. 14) Streets may be offered for public dedication or may be privately owned by homeowners association. Streets must meet the applicable design requirements set forth in the subdivision ordinance. 15) The director shall have the authority to authorize the developer to substitute sidewalks with alternate pedestrian walkways, such as nature trails. 16) Minimum lot area: a) The PDR district provides for a variety of dwelling unit styles and support uses with adherence to flexible lot area and yard requirements provided in other districts; the minimum residential lot area shall be limited to three thousand five hundred (3,500) square feet. The zero lot line provision may be utilized in a PDR development. b) Pre-existing dwellings: Dwellings that exist prior to the application of a PDR zone which shall remain shall be considered existing nonconforming structures and shall be subject the provisions of chapter 11 of this LDC. c) Setback from any public or private right-of-way: Any building that is erected, reconstructed, or moved shall be setback a minimum of fifteen (15) feet from the right-of-way line. However, for a corner lot, the minimum side distance from any right-of-way line is ten (10) feet. d) Accessory buildings shall not be placed in the front yard not closer than five (5) feet to the side or rear property lines. 17) Height requirements. Maximum building height shall be thirty-five (35) feet. 18) Open space requirements. Fifteen (15) percent of the total PDR area shall be maintained as open space. Street rights-of-way, parking lots, building areas (as defined) and yards held in individual ownership shall not constitute any part of the required open space; however, building areas for recreational facilities may be computed as open space. The city council may also require the developer to provide the city with an option to purchase open space sites at fair market prices for the development of future public recreational areas and/or community facilities. Said option shall become null and void if the city has not exercised the option prior to the completion of seventy (70) percent of the proposed dwelling units in the PDR. Any open space land use not included under approval of the PDR preliminary plan must be reviewed by the planning board and approved by the city council prior to its development. 19) Uses within a PDR zoning district shall comply with the table of permitted uses in chapter 5 of this LDC. 20) Condominiums shall be recorded in accordance with the North Carolina Condominium Act (N.C.G.S. [ch.] 47C). 21) Where applicable, PDR developments are subject to subdivision and PDR provisions of this LDC. 5. Residential cluster developments. Residential cluster development provides an alternative to conventional single-family residential development. Plans for the construction of a residential cluster development shall be approved by the planning board in accordance with the requirements of the subdivision ordinance. A residential cluster development is defined as a development design wherein conventional zoning standards are relaxed to permit modifications in lot area, lot width, lot frontage, lot coverage, rear and side required yards, sidewalks, and public street access, and to save infrastructure development cost, environmental damage, energy use and land resources by concentrating dwellings in specific areas of the site without increasing the net density above that which would normally be allowed pursuant to section 601 District Dimensional Standards. It is the intent of this section to allow a reduction in lot size with the result that land area "saved" by so doing will become usable open space (common area) accessible by all residents of the residential cluster development. 1) General requirements. a) Residential cluster developments shall contain not less than five (5) net acres. For the purposes of this section, "net acres" shall be the total area of all lots and common area(s) exclusive of public street rights-of-way. Addition to any existing residential cluster development may be allowed provided such addition meets or exceeds all other applicable requirements. b) Residential cluster development is a use-by-right in A-1, O-I, R-15, R-10, R-8, R-6, R-6MFA and PDR districts. Such development shall be exempt from the conventional zoning standards relative to lot area, lot width, lot frontage, lot coverage, and required yards, normally applicable to such districts provided such development complies with minimum standards set forth in this section. c) Land uses specified as a special use in the applicable districts by the table of permitted uses shall meet all of the requirements as identified in this LDC. d) In locations where the residential cluster development is proposed to be developed immediately adjacent to a developed or undeveloped single-family subdivision which is recorded in the register of deeds office and is zoned solely for single-family land use, the planning board may require at its discretion one (1) tier of lots not utilizing the residential cluster development regulations to be developed around the perimeter or a portion thereof of the property in which the residential cluster development design is to be employed. e) Streets may be offered for public dedication or may be privately owned by homeowners association. Streets must meet the applicable design requirements set forth in the subdivision ordinance. f) The director shall have the authority to authorize the developer to substitute sidewalks with alternate pedestrian walkways, such as nature trails. 2) Density. The maximum number of dwelling units allowed per acre are shown in the residential cluster development density table below. These requirements for residential cluster development supersede the requirements of the table of area, yard and height requirements of this LDC. Table 7-9. Density for Cluster Developments (District) | (Dwelling Units Per Acre) A-1 | 2 R-15 | 3 R-10 | 4 R-8 | 5 R-6 | 6 R-6MFA | 10*/6** O-I | 10*/6** PDR | 6 *For cluster developments with more than five (5) net acres and less than ten (10) net acres. **For cluster developments with greater than ten (10) net acres. 3) Lot design and minimum dimensional standards. a) Because the dwelling unit density identified in the preceding section is consistent with conventional single-family development within the district in which the development is located, no minimum lot size or width is required for the subdivision of a residential cluster lot. b) For all of the residential cluster subdivision construction plats approved by the Planning Board prior to June 13, 1994, the following yard setback provisions shall apply. There are no yard setbacks required for buildings constructed for residential cluster development purposes from interior lot lines for residential cluster lots. c) Any residential or nonresidential building construction shall setback a minimum of twenty (20) feet from any public or private street right-of-way line as identified on the planning board approved construction plat and the initial tract of land of the residential cluster development perimeter. d) For residential cluster development construction plats approved by the planning board after June 13, 1994, the following shall apply. The conventional lot setbacks identified in the Table of Area, Yard and Height Requirements for each district shall apply to each cluster lot. In instances where a dwelling shares a common wall with another dwelling unit on one (1) or both sides, there shall be no side yard setback from the built-on side lot line. Minimum side and rear yard setbacks shall be five (5) feet from all interior side and interior rear lot lines. e) There shall be a minimum setback of twenty (20) feet from the perimeter of the initial tract of land of the residential cluster development. This area may be counted toward the dwelling density if the area is dedicated as common area and is accessible to the residents of the development. f) Each lot shall abut a public or private street right-of-way. 4) Common area. A residential cluster development shall provide open space subject to all of the following requirements: a) Such open space shall be greater or equal in area to the total amount of area by which each lot was reduced below the minimum lot size requirement of the prevailing zoning district, or as provided under subsection b) below, whichever is greater. b) Residential cluster developments shall reserve not less than twenty (20) percent of the net acreage as common space. c) Such area shall not be used as a residential building site. For the purposes of this section, picnic areas or shelters, ball fields, walking or jogging trails, boat ramps and docks or similar recreational facilities may be allowed. d) Such area shall not be devoted to any public street right-of-way or private street easement, private driveway or parking area. e) Such area shall be left in its natural or undisturbed state if wooded at the time of development, except for the cutting of trails or walking or jogging or, if not wooded at the time of development, is improved for the uses listed under subsection c) above, or is properly vegetated and landscaped with the objectives of creating a wooded area or other area that is consistent with the objective set forth in subsection f) below. f) Such area shall be capable of being used and enjoyed for purposes of informal and unstructured recreation and relaxation or for horticulture if not devoted to other allowable uses in this subsection. g) Such area shall be legally and practically accessible to the residents of the development. h) A minimum of one-half (½) of the required open space shall be contained in one (1) continuous undivided part. An open space area designed around the perimeter of the cluster development shall not constitute any portion of this required open space. i) Such area shall be perpetually owned and maintained for the purposes of this section by the homeowners association. j) The location and arrangement of any open space shall be subject to planning board approval. k) There shall be no further subdivision of homeowners association owned property when the final plat of the initial subdivision of the residential cluster development has been recorded in the register of deeds office. 5) Homeowners association. See section 713 of this LDC for regulations relative to homeowners associations. 6) Validity. Approved site development plans shall be valid for a period of two (2) years from the date of approval. Upon the expiration of said two (2) year period of validity, a revised site development plan shall be required to be submitted as a new project.

(Ord. No. O-2005-34b, § 1(Att. A), 5-9-05; Ord. No. 0-2007-35, § 2, 6-11-07; Ord. No. O-2009-2, § 5, 1-12-09; Ord. No. O-2009-101, § 1, 9-14-09; Ord. No. O-2011-37, § 3, 5-9-11; Ord. No. O-2018-78, §§ 2, 3, 8-13-18; Ord. No. O-2021-2, §§ 3, 4, 1-11-21)

Ask a question about Rocky Mount law

Corpus searches the Rocky Mount sections it holds and shows the ones that match, with their citations. Free, no sign-in.