20.06.340 Section 708.4.2 Exception 4 Amended; Fireblocks and Draftstops in Combustible Construction.
Exception 4 to Section 708.4.2 of the International Building Code is amended to read as follows: 4. In Group R-2 occupancies up to and including four stories in height in buildings not exceeding 60 feet (18288 mm) in height above grade plane, the attic space shall be subdivided by draftstops into areas not exceeding 3,000 square feet (279 m2). (: Ord. 20257 §34; October 19, 2015).
(Ord. 21117 §33; August 23, 2021)