20.06.450 Section 1015.3 Amended; Item 4 Added; Height.
Section 1015.3 of the International Building Code is amended to read as follows: 1015.3 Height. Required guards shall be not less than 42 inches (1067 mm) high, measured vertically as follows: (1) From the adjacent walking surfaces; (2) On stairways and stepped aisles, from the line connecting the leading edges of the tread nosings; (3) On ramps and ramped aisles, from the ramp surface at the guard; and (4) Exterior balcony railings with no exceptions allowed. Exceptions: (1) For occupancies in Group R-3 not more than three stories above grade in height and within individual dwelling units in occupancies in Group R-2 not more than three stories above grade in height with separate means of egress, required guards shall be not less than 36 inches (914 mm) in height measured vertically above the adjacent walking surfaces. (2) For occupancies in Group R-3, and within individual dwelling units in occupancies in Group R-2, guards on the open sides of stairs shall have a height not less than 34 inches (864 mm) measured vertically from a line connecting the leading edges of the treads. (3) For occupancies in Group R-3, and within individual dwelling units in occupancies in Group R-2, where the top of the guard serves as a handrail on the open sides of stairs, the top of the guard shall be not less than 34 inches (864 mm) and not more than 38 inches (965 mm) measured vertically from a line connecting the leading edges of the treads. (4) The guard height in assembly seating areas shall comply with Section 1029.17 as applicable. (5) Along alternating tread devices and ships ladders, guards where the top rail serves as a handrail shall have height not less than 30 inches (762 mm) and not more than 34 inches (864 mm), measured vertically from the leading edge of the device tread nosing. (6) In Group F occupancies where exit access stairways serve fewer than three stories and such stairways are not open to the public, and where the top of the guard also serves as a handrail, the top of the guard shall be not less than 34 inches and not more than 38 inches measured vertically from a line connecting the leading edges of the treads. (: Ord. 20257 §45; October 19, 2015).
(Ord. 21117 §43; August 23, 2021)
Ask a question about Lincoln law
Corpus searches the Lincoln sections it holds and shows the ones that match, with their citations. Free, no sign-in.