20.06.500 Section 1403.2 Amended; Water-Resistive Barrier.

Section 1403.2 of the International Building Code is amended to read as follows: 1403.2 Water-resistive barrier. One layer of water-resistive barrier (WRB), free from holes, complying with ASTM E2556 for type II WRB or ICC acceptance criteria (AC212) for liquid weather barriers or other WRB systems as approved by the building official shall be applied over sheathing of all exterior walls. Such WRB shall be applied horizontally, with the upper layer lapped over the lower layer not less than two inches. Where vertical joints occur, the WRB shall be lapped not less than six inches. The WRB shall be continuous to the top of walls and terminated at penetrations and building appendages with flashing as described in Section 1404.4, in such a manner as to provide a continuous water resistive barrier behind exterior wall veneer. Manufactured and natural adhered masonry veneer and stucco shall be installed over an approved rain screen (drainage system) that has a minimum depth of 1/8 inch. The 1/8 inch space shall be formed by the use of any non-corrodible furring strip, drainage mat, or drainage board. A water-resistant barrier shall be installed between the rain screen and the wall sheathing. Asphalt paper less than (30#) shall not be permitted as a water-resistant barrier for adhered veneer and stucco. Exceptions: (1) A space is not required where the exterior veneer is installed with a second WRB complying with Section 1403.2, which is manufactured in a manner to enhance drainage and meets the 75% efficiency drainage requirement of ASTM E2273, ICC-ES AC24, ICC-ES AC235 or other recognized national standards and is installed over a WRB complying with Section 1403.2. (2) The water-resistive barrier for detached accessory building less than 120 square feet is not required. (: Ord. 20257 §50; October 19, 2015).

(Ord. 21117 §47; August 23, 2021)

Ask a question about Lincoln law

Corpus searches the Lincoln sections it holds and shows the ones that match, with their citations. Free, no sign-in.