§ 20.14.080 — Section C402.4.2 Amended; Minimum Skylight Fenestration Area
Lincoln, Nebraska Municipal Code (enCodePlus online edition as published 2026-11-08 (history notes seen through Ord. 21775, Sept. 15, 2025)) · Lincoln Municipal Code § 20.14.080
Corpus is an independent public-information project, not the official City of Lincoln website. Stable reference: corpuslaw.us/code/75f3a0bf-df80-4c7e-acc0-129619f52f0c
20.14.080 Section C402.4.2 Amended; Minimum Skylight Fenestration Area.
Section C402.4.2 of the International Energy Conservation Code is hereby amended as follows: C402.4.2 Minimum Skylight Fenestration Area. In an enclosed space greater than 10,000 square feet (929 m2) in floor area, directly under a roof with not less than 75 percent of the ceiling area with a ceiling height greater than 15 feet (4572 mm), and used as an office, lobby, atrium, concourse, corridor, storage space, gymnasium/exercise center, convention center, automotive service area, space where manufacturing occurs, nonrefrigerated warehouse, retail store, distribution/sorting area, transportation depot or workshop, the total toplit daylight zone shall be not less than half the floor area and shall provide one of the following: (1) A minimum skylight area to toplit daylight zone of not less than 3 percent where all skylights have a VT of not less than 0.40 as determined in accordance with Section C303.1.3. (2) A minimum skylight effective aperture of not less than 1 percent, determined in accordance with Equation 4-4. Skylight Effective Aperture = (0.85 x Skylight Area x skylight VT x WF) / Toplit Zone (Equation 4-4) where: Skylight area = Total fenestration area of skylights. Skylight VT = Area weighted average visible transmittance of skylights. WF = Area weighted average well factor, where well factor is 0.9 if light well depth is less than 2 feet (610 mm), or 0.7 if light well depth is 2 feet (610 mm) or greater. Light well depth = Measure vertically from the underside of the lowest point of the skylight glazing to the ceiling plane under the skylight. Exception: Skylights above daylight zones of enclosed spaces are not required in: (1) Buildings in Climate Zones 6 through 8. (2) Spaces where the designed general lighting power densities are less than 0.5 W/ft2 (5.4 W/m2). (3) Areas where it is documented that existing structures or natural objects block direct beam sun-light on not less than half of the roof over the enclosed area for more than 1,500 daytime hours per year between 8 a.m. and 4 p.m. (4) Spaces where the daylight zone under rooftop monitors is greater than 50 percent of the enclosed space floor area. (5) Spaces where the total area minus the area of sidelight daylight zones is less than 2,500 square feet (232 m2), and where the lighting is controlled in accordance with Section C405.2.3. ().
(Ord. 21115 §3; August 23, 2021)
Ask a question about Lincoln law
Corpus searches the Lincoln sections it holds and shows the ones that match, with their citations. Free, no sign-in.