20.14.090 Section C403.5 Amended; Economizers (Prescriptive).
Section C403.5 of the International Energy Conservation Code is hereby amended as follows: C403.5 Economizers (Prescriptive). Economizers shall comply with Sections C403.5.1 through C403.5.5. An air or water economizer shall be provided for the following cooling systems: (1) Chilled water systems with a total cooling capacity, less cooling capacity provided with air economizers, as specified in Table C403.5(1). (2) Individual fan systems with cooling capacity greater than or equal to 72,000 Btu/h (20.1 kW) in buildings having other than a Group R occupancy, (3) The total supply capacity of all fan cooling units not provided with economizers shall not exceed 20 percent of the total supply capacity of all fan cooling units in the building or 300,000 Btu/h (88 kW), whichever is greater. Individual fan systems with cooling capacity greater than or equal to 270,000 Btu/h (79.1 kW) in buildings having a Group R occupancy. The total supply capacity of all fan cooling units not provided with economizers shall not exceed 20 percent of the total supply capacity of all fan cooling units in the building or 1,500,000 Btu/h (440 kW), whichever is greater. Exceptions: Economizers are not required for the following systems: (1) Individual fan systems not served by chilled water for buildings located in Climate Zones 1A and 1B. (2) Where more than 25 percent of the air designed to be supplied by the system is to spaces that are designed to be humidified above 35°F (1.7°C) dew-point temperature to satisfy process needs. (3) Systems expected to operate less than 20 hours per week. (4) Systems serving supermarket areas with open refrigerated casework. (5) Where the cooling efficiency is greater than or equal to the efficiency requirements in Table C403.5(2). (6) Systems that include a heat recovery system in accordance with Section C403.9.5. (7) VRF systems less than 75,000 Btu/h (22kW). (8) Water source Heat Pump systems less than 62,000 Btu/h (18kW). ().
(Ord. 21115 §4; August 23, 2021)
Ask a question about Lincoln law
Corpus searches the Lincoln sections it holds and shows the ones that match, with their citations. Free, no sign-in.