§ 5.10.070 — Floor Diking and Dike Tank
Lincoln, Nebraska Municipal Code (enCodePlus online edition as published 2026-11-08 (history notes seen through Ord. 21775, Sept. 15, 2025)) · Lincoln Municipal Code § 5.10.070
Corpus is an independent public-information project, not the official City of Lincoln website. Stable reference: corpuslaw.us/code/a3033856-10d0-42dd-b40d-cbee53111c22
5.10.070 Floor Diking and Dike Tank.
A means of preventing cleaning liquid leaks from escaping the machine or its enclosure shall be provided. This shall include some method of diking the floor of the enclosure or machine base to impound a liquid volume equal to the solvent capacity of the system. Some means shall be provided for safely removing the solvent from this sump in the event of a leak. This may be accomplished by gravity flow to a standby holding tank; this tank shall be vented to the outside. Notwithstanding the provision for localized containment of liquids from accidental leaks, bulk solvent storage and the recirculation system shall be so designed as to reasonably preclude any leakage and uncontrolled exposure to the room atmosphere.
(Ord. 15457 §7; March 5, 1990: P.C. §5.56.070: Ord. 7715 §7; May 1, 1962)
Ask a question about Lincoln law