Sec. 30-274. - Submittal requirements.

(a) The material required to be submitted for each permit application filed under division 5 is as follows: (1) Completed application to include property owner's name, contractor's name and license number, architect's, landscape architect's and/or engineer's name and contact information as applicable for the project. (2) Plan review fee. (3) Permit fee (required at time of permit issuance). (4) Park fee if applicable (required at time of permit issuance). (5) Utility development impact fees (required at time of permit issuance). (6) Construction drawings. a. The building official having jurisdiction may require submission of any specifications, drawings, or diagrams necessary to show clearly the kind, extent, and occupancy of building construction work covered by application for permits required. b. The building official having jurisdiction shall require that all plans and specifications be prepared and sealed by a New Mexico registered architect, in conformance with the provisions of the State Architectural Act/Rules and Regulations, and/or by a New Mexico registered state professional engineer, in conformance with the provisions of the State Engineering and Surveying Practice Act/Rules and Regulations, and/or by a New Mexico registered Landscape Architect, in conformance with the provisions of the State Landscape Architect Act/Rules and Regulations, for all uses as listed in Chapter 3 of the International Building Code with the exception of: 1. Single-family one and two family dwellings not more than two stories in height; 2. Multiple dwellings not more than two stories in height containing not more than four dwelling units of wood-frame construction; provided, this paragraph shall not be construed to allow a person who is not registered under the Architectural Act to design multiple clusters of up to four dwelling units each to form apartment, townhome or condominium complexes where the total exceed four dwelling units on any lawfully divided lot; 3. Garages or other structures not more than two stories in height which are appurtenant to buildings described in the above two paragraphs of this subsection; 4. Non-residential buildings or additions having a total occupant load of ten or less and two stories or less in height; does not include E-3 (day care), H (hazardous) or I (institutional) occupancies, all of which must be certified by an architect or engineer, or both in accordance with paragraph "c" below. c. The single seal of either an engineer or architect meets the requirement for professional certification on projects that do not exceed a construction valuation of $400,000.00 and have a total occupant load between 11 and 50. The professional seals of both an architect and engineer (or engineers) are required on projects that exceed either the $400,000.00 valuation or the 50 occupant load. d. Any installation with a calculated service capacity over 100 kVA single-phase or over 225 kVA three-phase shall be stamped by an Electrical Engineer registered in accordance with the New Mexico Engineering and Surveying Practice Act. This requirement shall not apply to remote installations such as irrigation pumps. e. Construction drawings shall be blueline or similar process and drawn to adequately display appropriate information, the minimum scale to be one-eighth inch = 1.0 foot consisting of the information listed in subsections (6)a, (6)b, and (6)c above. Permit applications for mobile/manufactured homes are exempt from submitting construction drawings as well as items i.—v. of subsection 2. below, but shall comply with site plan requirements i.—xv. of subsection 1. below. 1. Site plan. The site plan shall be either blueline or a similar process on paper measuring at least 18 inches × 24 inches. Copies submitted shall be legible and at a scale that accurately represents the information. The following information shall be provided on the site plan: i. Name, address, phone number and license number of builder/contractor. ii. Name, address, phone number and registration number(s) of all required registered professionals and identification of principal design professional(s) responsible for project coordination and communication. iii. Date of preparation, north arrow, and written and graphic scales. iv. General legal description of subject property. If the tract is not within an approved and filed subdivision, a vicinity map must be included showing the exact location of the property. The site plan shall include the entire lot or tract. v. Boundary lines, including dimensions and angles. vi. All adjacent streets, public rights-of-ways, and easements shall be shown and labeled. Location of median openings (if existing) fronting the property shall also be shown. vii. Zoning or proposed zoning of subject parcel of land. viii. Curbing, gutters, sidewalks, and parkways shall be shown and labeled, with dimensions shown for widths. All curb cuts shall be shown as well as those located on adjacent lots within 25 feet of property lines. Clear sight triangles on corner lots and entrances to parking areas shall be included. ix. Required setback lines shown as dashed lines and labeled. x. All structures shall be accurately located and labeled on site plans, including accessory structures, porches, carports, patios, concrete slabs, etc. xi. All dimensions shall be shown from the closest points between parts of a structure (i. e., building, porch, carport, etc.) and perpendicular to the property lines. xii. Retaining walls, with elevations shown on both sides of the wall, including wall height (if applicable). xiii. Parking spaces, driveways, garages, carports and other parking areas shall be labeled as such, with dimensions shown, in compliance with zoning code article IX. xiv. Drainage plan with appropriate elevations and drainage flow arrows shall be shown on plans in accordance with filed subdivision grading/drainage plan for new construction, to include all drainage calculations, and ponding area size(s) and location(s). xv. Indicate grades for front yard, pad, finished floor, backyard and existing grades outside property line. xvi. Site plan shall include existing and proposed finish contour lines. Some spot elevations may be required. xvii. Locations and sizes of available utility services, showing proposed taps, fire hydrant locations, and available sewer, water and gas. xviii. Fire and emergency services department access. 2. Construction drawings. Building, mechanical/plumbing and electrical drawings prepared by appropriate professionals licensed in the state shall be required as determined by the State of New Mexico Board of Examiners for Architects and the New Mexico Board of Registration for Professional Engineers and Surveyors. Blue line copies or similar process are to be used with a sheet size minimum of 18 inches × 24 inches, consisting of the following: i. Building code analysis, to be on cover sheet: A. Total building area (square feet). I. Occupancy type. II. Construction type. III. Allowable floor area calculations. IV. Special requirements - wind speed, seismic, and snow load. V. Occupant load. VI. Means of egress VII. Exits required and provided. VIII. Exit width required and provided. IX. Exit arrangement. X. Travel distance. XI. Doors—Swing, hardware, rating. XII. Fire separation walls. XIII. Fire protection system requirements. B. Roof construction requirements. C. Corridors—Width, height, dead ends, intervening rooms, rating. D. Stairways—Width, height, rating, landings, handrails. E. Occupancy and area separations. ii. Foundation plan/floor framing plan showing sizes and location of footings, beams, walls, slabs, joists, decking, etc. iii. Foundation sections/details showing elevations, dimensions, reinforcing, anchorage, connections, sub-grade soil preparation, etc. (min. scale ⅜ inch = 1.0 foot). iv. Framing plan showing size, location, construction, spacing, etc. of bearing walls, columns, girders, beams, joists, rafters, trusses, etc. v. Roof/floor framing sections/details showing relationships of framing members, elevations, dimensions, reinforcing, anchorage, connections, slopes, etc. (min. scale ⅜ inch = 1.0 foot) vi. Floor plan showing rooms and spaces clearly indicating: exit paths; fire walls; door/opening types, ratings, and locations; finishes; dimensions; accommodations for accessibility by the physically disabled, etc. vii. Indicate per International Fire Code (IFC) and other fire-related codes, as amended, the locations of the following: A. Portable fire extinguishers. B. Fire protection systems: I. Fixed extinguishing and sprinkler systems; II. Cooking equipment; III. Flammable and combustible liquid storage rooms (electrical). C. Standpipe requirements. D. Exit lights and/or signs, emergency lighting. E. Flame spread ratings. F. Fire doors and windows. G. Smoke and heat vents. H. Fire and smoke dampers. viii. Building elevations showing relative heights of architectural elements, floor-to-floor heights, finish floor elevations, overall building height, finish materials, etc. ix. Wall sections showing relationships of members, types and locations of materials and systems, elevations, dimensions, slopes, relationships to stairs, existing structures (if any), etc. x. The construction documents shall include plumbing plans and a riser diagram of the work. Where appropriate, the construction documents shall indicate the direction of flow, all pipe sizes, grade of horizontal piping, loading, and location of fixtures and appliances. Equipment and fixture schedules shall also be required. xi. Construction documents for heating, ventilation and air conditioning shall be drawn to scale and shall be sufficient clarity to indicate the location, nature and extent of the work proposed and show in detail that work conforms to the provisions of this Code and equipment schedule. Equipment schedules shall be provided in accordance with the International Energy Conservation Code (IECC). xii. Electrical plans to show the following: A. Load calculations, fault current calculations and how short circuit protection will be provided. Show that the new service meets code requirements to adequately supply power to the load and safely interrupt the available fault current. B. Riser diagram (and single line diagrams if applicable) with all conduit and wire sizes and all grounding details. C. Locations for all receptacles, switches, panels, light fixtures (interior, exterior and site), exit lights/signs, fire/smoke dampers, and emergency lighting with circuiting and wire sizes. D. Fixture schedule and panel schedules. E. All low voltage systems. F. Point of connection to utility. G. Compliance with the City of Las Cruces Outdoor Lighting Ordinance. xiii. Compliance with the International Energy Conservation Code - including worksheets. xiv. Compliance with Americans with Disabilities Act. xv. Locations and sizes of available utility services showing proposed sewer water, gas taps, and fire hydrant locations, and available water. xvi. Fire and emergency services department access. 3. Landscaping drawings. A landscape and irrigation plan of all landscape space, including street rights-of-way, shall be approved by the city before building permits can be issued within the following zones: M-3, M-1 M-2, MT, O-1, O-2, C-3, C-2, C-1, R-4, R-3, and R-2. Landscaping drawings shall be blueline or similar process and drawn to accurately display appropriate information. Blueline copies or similar process are to be a minimum of 18 inches × 24 inches and consist of the following: i. Name, address and phone number of landscape architect responsible for completed project. ii. Written and graphic scales (must be one inch = ten feet or one inch = 20 feet), north arrow, property lines with dimensions, adjacent streets, with building, and landscape areas clearly labeled. iii. Landscape calculation: A. Landscape area = 15 percent of site area minus building area; or B. 0.15 x (site area - building area). C. If different, overlay zone requirements. iv. Plant material list with plant key. v. Type, size (at installation), and location of plant material whether new or relocated. vi. Irrigation plan, with location(s) and size(s) of backflow prevention devise(s), pipe(s), head(s), and water meter. vii. Topography map showing grades or spot elevations. Clear sight line distances for traffic must be taken into account. See city design standards, article VI, for specific design standard information. (32-405 LCMC) 4. Utility drawings. The following information is required on utility site plans submitted for approval. Drawings shall be blueline or similar process and drawn to accurately display appropriate information. Blueline copies or similar process are to be a minimum of 18 inches × 24 inches and consist of the following: i. North arrow, scale and address of proposed building. ii. Point of water service connection to water main and size of water service line. iii. Required water load in gpm to adequately size water service line and meter. iv. Point of sewer service connection to sewer main and size of sewer service line. v. Point of gas service connection to gas main. vi. Location and size of all existing and proposed utility main lines, service lines, meters, electrical enclosures and easements. vii. Location of all concrete flat work. viii. Location of all retaining walls and details. ix. Location and details of all ponding areas. x. Location of all trees or the following note— TREE NOT TO BE PLANTED CLOSER THAN FIVE FEET TO GAS SERVICE LINE. xi. Required BTUH or MCFH to adequately size gas service line and meter. xii. Utility mains in private property need adequate easements for operation and maintenance. (All easements must be filed and recorded with the county before approval and a recorded copy submitted with plans for verification.) xiii. Location of all proposed fire hydrants. xiv. Location of all proposed manholes. xv. Location of all proposed valves. xvi. Gas riser details. xvii. Bypass at riser for one and one-quarter inch or larger gas service detail. xviii. Water service details. xix. Sewer service details. xx. Fire hydrant details (if a new one is being installed). 5. Dust control plan. A dust control plan meeting the requirements of Chapter 32, Las Cruces Municipal Code must be submitted with the permit application.

(Ord. No. 2478, § I, 11-17-08)

Ask a question about Las Cruces law

Corpus searches the Las Cruces sections it holds and shows the ones that match, with their citations. Free, no sign-in.