§ 278-5 — Storage of film
Code of Ordinances of the City of Buffalo, New York (Code 2026-03-31: eCode360 publication current through the 2026-03-31 codification (imported 2026-11-12)) · Buffalo City Code § 278-5
Corpus is an independent public-information project, not the official City of Buffalo website. Stable reference: corpuslaw.us/code/471560b0-69c8-4335-8b25-96efc66bc7ac
§ 278-5: Storage of film.
A. All such films shall be kept or stored in a vault or cabinet, provided and used solely for such purposes, and shall not be removed therefrom except while the same is in actual process of being displayed, inspected, examined, repaired, demonstrated, shipped or received. All film shall at all times be kept or stored in individual cans or containers, except while the same is in actual process of being displayed, wound or rewound, inspected, examined, repaired or demonstrated. B. Two hundred reels (1,000 pounds) or less may be stored in cabinets, but not over 100 reels may be placed in any one cabinet. Any storage in excess of 200 reels shall be in film vaults. C. No film vault shall exceed 750 cubic feet in actual storage capacity, including aisles. D. A cabinet shall have a minimum volume of one cubic foot for each 19 pounds of film capacity and shall in no case have a volume exceeding 30 cubic feet. E. The floor and walls of every film vault shall be made of brick at least eight inches thick or of three-cell hollow tile at least 12 inches thick, laid with webs horizontal, or of the interlocking type; or of reinforced concrete at least six inches thick, unless the vault floor is constructed directly upon the ground, in which case a minimum floor thickness of four inches of concrete, not reinforced, is permitted. In a fireproof building, the building floor may be used as the floor of the vault if equivalent in fire resistance to the requirements given above. Vaults shall be supported by masonry or steel of sufficient strength to carry the load safely. Beams shall rest at both ends on steel girders, iron or steel columns or walls or piers of masonry. The supports shall afford at least four hours' protection, as determined by the Standard Fire Test Specifications. F. Where the design of the building is such that an excessive floor load would result from having the film vault filled with water, the film vault shall be provided with one or more scuppers, giving a total area of inlet equal to three square inches for each sprinkler head installed in the film vault. G. The roof of vault shall be an independent reinforced-concrete roof at least six inches thick. In a fireproof building, where the floor above is equivalent to this, it may serve as the roof if side walls are rigidly tied into it. In construction of this type, a false ceiling, constructed of metal lath and cement plaster one inch thick or the equivalent and with no openings to the concealed space above, may be used to limit the total interior vault space to 750 cubic feet. A vent may extend through this false ceiling and concealed space. H. Film vaults shall not be provided with skylights or glass windows other than as specified under vents. I. Proximity to boilers, stacks or other sources of heat shall be avoided, and no heating coils or other heating appliances shall be allowed in any film vault. J. A fire door shall be provided on each face of the wall on door openings. Doors shall conform as to construction and installation to Class B of the National Board of Fire Underwriters' regulations for the protection of openings in enclosures to vertical communications through buildings. The interior door shall be automatic. The outer door shall be of the swinging type and close into a rabbet or otherwise be made tight to prevent passage of flame around edges; it shall be self-closing and, if fastened open, shall be arranged to close automatically in case of fire originating in or out of vault. K. Racks in film vaults shall be built of metal or other incombustible material and arranged to prevent film containers being placed in other position than on edge in a vertical position. Vertical incombustible partitions, equivalent in heat insulation and durability to three-eighths-inch hard asbestos and extending from floor to ceiling, shall be provided to divide racks into sections such that the amount of film protected by any sprinkler shall not exceed 830 pounds; partitions shall be substantial and have exposed edges protected. Means shall be provided to keep the containers on each side of such partitions an inch away from the same. Racks shall not obstruct any vent openings. Racks shall be so arranged that film cannot be placed under or between containers in the vertical position. Film shall not be stored or kept on the floor, unless in shipping containers approved by the Interstate Commerce Commission. L. All lights in film vaults shall be at the ceiling and of the fixed marine type, with vaporproof globes and conduit wiring. All switches shall be outside the vault and shall be arranged with a small pilot light to indicate on outside of vault whether lights are on or off. M. Each film vault and each compartment of a cabinet when the cabinet contains more than 50 pounds of film shall separately vent to the outer air, with a vent having a minimum effective sectional area of 70 square inches for each 100 reels' capacity (equivalent to 140 square inches per 1,000 pounds of film). For a standard vault of 750 cubic feet, the vent opening shall be 1,400 square inches. N. The outlet of each vent shall be made to face a street, court or other clear space, giving a distance of at least 25 feet from the face of the vent to doors, windows, lot lines, other openings or exterior fire escapes in a vertical plane parallel to and facing the vent outlet. There shall also be a distance of not less than 15 feet from the side of the vent to doors, windows, lot lines, other openings or exterior fire escapes in a vertical plane at right angles to the plane in which the vent opening is placed. The requirements herein set out shall not apply to openings facing in the same direction as that in which the vent opening faces or to the rear of the face of the vent. O. All horizontal or vertical vent flues inside of the building shall be of a construction equivalent to that of chimneys as specified in the Building Code,[1] except that for 100 or less reels, the flue may be riveted sheet metal of at least No. 18 United States gauge, covered with one inch of approved heat insulation material and not nearer than nine inches to any combustible material. Exterior metal flues shall be of a construction equivalent to that of smokestacks. P. Each vent opening directly through an exterior wall shall be protected against the weather by single thickness glass [one-sixteenth (1/16) inch thick], painted a dark color or by other incombustible fragile material, in a sash arranged to open automatically in case of fire by the use of an approved releasing device placed inside the film storage vault. The area of the glass shall be the effective sectional area of the vent openings. No pane of glass shall be smaller than 200 square inches. Any protection equivalent to the above may be accepted in lieu thereof. Q. A light wire screen not coarser than one-eighth-inch mesh shall also be placed over each vent, so arranged as not to interfere with the automatic operation of the sash. Bars or screen designed to prevent burglary or injury to contents shall not have a mesh of less than four inches, shall be located inside the light wire screen and shall give a net opening equal to that called for under Subsection M. R. A permanent guard shall be installed to prevent films from being forced against the vent openings. S. Cabinets shall be of approved construction. Cabinets containing in excess of 50 reels of film shall be divided into at least two distinct compartments, each compartment provided with an independent door; the separating partition shall be practically airtight and of substantial construction. In general, cabinets should be of a design and so insulated as to stand at least a five-minute fire test conducted in accordance with the standard time-temperature test and also insulated to prevent the contents of one compartment being involved by a fire in the other. The following specifications will fulfill the above requirements: The racks or drawers shall be so arranged that the film containers immediately adjacent to the partitions do not touch same on either side. Spacers should be provided so as to have such containers at least 1/2 inch away from the partition on either side. Separating partitions may be constructed of three-eighths-inch hard asbestos board or of one-fourth-inch soft asbestos board enclosed between steel or iron sheets, No. 22 United States gauge. The exterior sides of cabinet and doors may be composed of one-fourth-inch asbestos board carried on a framework of angles of 1 1/4 by 1 1/4 x 1/8 inches or may be made of No. 18 United States gauge metal, double-walled with 1 1/2 inches of air space. The shelves or racks within the cabinet must be of metal and arranged to store film containers on edge and so arranged that film cannot be placed under or between containers in the vertical position. Doors to compartments shall be so arranged as to remain normally closed, shall be kept closed by catches at three points and shall be normally sufficiently tight to prevent the entrance of flame due to the burning of a reel of film in an adjoining compartment. Doors on divided cabinets shall be hinged on the separating partitions at the center of the cabinet so that they will not expose the contents of one compartment to the other in case a door is open.
Ask a question about Buffalo law
Corpus searches the Buffalo sections it holds and shows the ones that match, with their citations. Free, no sign-in.
