§ 278-6 — Automatic sprinklers
Code of Ordinances of the City of Buffalo, New York (Code 2026-03-31: eCode360 publication current through the 2026-03-31 codification (imported 2026-11-12)) · Buffalo City Code § 278-6
Corpus is an independent public-information project, not the official City of Buffalo website. Stable reference: corpuslaw.us/code/8c9d2bbf-8608-4338-9529-98ae7521ac35
§ 278-6: Automatic sprinklers.
A. Buildings, other than excepted in § 278-2, not of fireproof construction shall be equipped throughout with automatic sprinklers. B. Fireproof buildings, other than excepted in § 278-2, shall be equipped throughout all floors on which film is handled, as specified in § 278-5, with an approved automatic sprinkler system, and all communications from floors so occupied and equipped to other floors of the same or adjacent buildings shall be so protected by enclosures and approved automatic fire doors as to afford a degree of fire resistance equal to that afforded by the floor construction. C. Extra sprinkler heads shall be supplied, as may be required by the Commissioner of Fire, over: (1) Drying drums. (2) Joining or assembling tables. (3) Receiving and distributing counters and other places where an excessive amount of film is handled. D. Each film vault shall be equipped with automatic sprinklers, with a ratio of one head to each 62 1/2 cubic feet of total vault space, based on interior measurements. For a standard vault of 750 cubic feet, 12 standard automatic sprinklers are required. In no case shall storage space exceed 830 pounds of film per sprinkler. Sprinklers shall be arranged to give uniform distribution within the sections formed by the partitions required under § 278-5K; proper sheet-metal baffles shall be installed where necessary. Water supplies for automatic sprinklers shall be based on an estimate of 20 gallons a minute per head for 30 minutes, for the total number of heads in a vault, plus 1/2 the heads in any fire section on the same floor. Where tanks are depended upon, the minimum capacity shall be 10,000 gallons. Other details shall be as given in the National Board of Fire Underwriters' regulations governing the installation of automatic and open sprinkler equipment. E. Sprinkler systems for film vaults shall be equipped with a three-fourths-inch drip line and valve, which shall be used for a weekly test. Such test will not be required if a recording pressure gauge is attached to the drip line. F. Film storage cabinets holding over 50 pounds of film shall be equipped with at least one automatic sprinkler for each compartment. G. Each room, other than film vaults, in which film is handled or stored, shall be equipped with at least one approved two-and-one-half-gallon chemical extinguisher and one pail of water. H. Where considerable quantities of film are stored, additional protection shall be provided, as specified by the Commissioner of Fire.
Ask a question about Buffalo law
Corpus searches the Buffalo sections it holds and shows the ones that match, with their citations. Free, no sign-in.