§ 278-7: Lighting.

A. Incandescent electric lights are the only form of artificial illumination that will be permitted in any rooms where films are handled. Arc lights or other forms of electric lights may be used in studios only. All wiring and equipment shall conform to the National Electrical Code, be run in metal conduit and be properly protected by nonarcing, enclosed fuses. Lights placed in drying rooms shall have rigid fixtures and be protected by marine-type, vaporproof outer globes. Such vaporproof globes may be used in other locations, but any light not so protected shall be equipped with a substantial metal guard so arranged as to prevent accidental breakage of the globe. All lights shall be equipped with keyless sockets and operated by wall switches. For lights in film vaults, see § 278-5L. B. Illuminated signs reading EXIT in red letters six inches in height shall be placed at the exits of all dark rooms. C. Portable electric lights on extension cords are prohibited in any room in which film is handled or stored.