§ 131-157 — Self-service stations
Code of the City of Mount Vernon, New York · Mount Vernon City Code § 131-157
Corpus is an independent public-information project, not the official City of Mount Vernon website. Stable reference: corpuslaw.us/code/688a12fb-2d4a-47fc-a1e9-3f5e2d48f221
§ 131-157: Self-service stations.
A. A "self-service station" shall be defined as that premises or portion of a premises where gasoline, gasohol or diesel motor fuel are stored and sold and subsequently dispensed from fixed approved dispensing equipment as required by this section into the fuel tanks of motor vehicles or into approved containers by persons other than the service station attendant. Self-service stations shall be permitted when constructed, installed, maintained and operated in accordance with this section and other applicable provisions of the Code of the City of Mount Vernon, the New York State Uniform Fire Prevention and Building Code and the National Fire Protection Association 30A-87, Automotive and Marine Service Station Code. Remote, preset dispensing devices for gasoline, gasohol or diesel motor fuel shall be permitted at self-service stations when installed and operated in compliance with all of the provisions of this section. All electrically activated equipment and controls shall be Underwriters' Laboratories, Inc., approved and installed by a licensed electrician. B. Attendant duties, responsibilities and qualifications. (1) There shall be at least one qualified attendant on duty while the station is open to the public. (2) The attendant's primary duty shall be to supervise, observe and control the dispensing of such motor fuel. (3) The attendant shall be familiar with all of the provisions of the Fire Prevention Code and shall be responsible for the enforcement of all applicable provisions of this section. (4) The attendant shall be capable of performing the functions and assuming the responsibilities of the Fire Prevention Code. (5) The attendant shall be familiar with the operations of all fire-extinguishing equipment required under the Fire Prevention Code and shall be familiar with the emergency procedure and instructions. (6) The attendant shall prevent the dispensing of such motor fuels into portable containers not in compliance with the Fire Prevention Code. (7) The attendant shall be responsible to deactivate all pumps should it become necessary to leave the central control station unattended. (8) The attendant shall be responsible to handle all accidental spills immediately on occurrence. (9) The attendant shall be responsible to operate the fire extinguishers when needed. C. Central control station. All controls related to the dispensing of gasoline, gasohol or diesel motor fuel at a self-service station shall be centralized at one central control station. The central control station shall be so located as to permit the attendant to maintain visual contact over the entire premises with all operations while remaining within arms' length of all control systems. Permanent or portable obstructions to the vision of the attendant are prohibited. No portion of the dispensing operation shall be greater than 75 feet from the central control station. D. Control systems. The central control stations shall contain all of the systems and devices cited in this section: (1) Emergency controls, including the main power shutoff switch or switches for all pumps. (2) A voice communication system, such as but not limited to an intercom system, so as to allow direct voice communication at all times between the person dispensing such motor fuel and the attendant. (3) Portable fire extinguishers of a number and type approved by the Commissioner. (4) The controls for a fixed extinguishing system as required in Subsection G of this section. (5) A list of emergency procedures and instructions, conspicuously posted and visible to the attendant. (6) All control devices numbered to identify the applicable dispenser or dispensers. E. Dispensers. All dispensers shall comply with all of the provisions of this section. (1) All dispensers shall be numbered, and the numbers shall be visible at the central control station and to the person operating the dispenser. (2) All dispensers shall have a fixed extinguishing system, approved by the Commissioner, located at or in the vicinity of the dispensing devices. The fixed extinguishing system shall be in compliance with the National Fire Protection Association Standard 17-85. (3) All dispenser islands or individual dispensers shall contain a voice communication system for direct contact with the attendant at the central control station. (4) All dispenser islands or individual dispensers for self-service shall be designated "self-serve" or "self-service" by a sign visible from the street. F. General restrictions. The following restrictions shall apply to the operation of all self-service stations: (1) Operation of the dispensing device by other than a duly licensed motor vehicle operator is prohibited. (2) Only gasoline, gasohol or diesel motor fuel shall be dispensed at a self-service station. (3) No smoking is permitted in an area designated by the Commissioner. (4) The ignition of the vehicle being fueled must be shut off. (5) Latch hold open devices on hose nozzle valves are prohibited. G. Self-service-station automatic fire-extinguishing-system requirement. The Commissioner shall require a dry chemical fire-extinguishing system which shall operate and perform in compliance with National Fire Protection Association 17-85. (1) Plans for any proposed automatic dry chemical extinguishing system shall be submitted to the Commissioner for review and approval prior to installation. H. Retrofitted systems. If an existing system is to be expanded or additional coverage to other islands provided, the existing system shall be modified and interfaced with any new components so that the requirements of this article shall be complied with. Plans shall be submitted for approval by the Commissioner prior to such expansion or additional coverage and shall conform to manufacturer's specifications. I. Testing and inspections. (1) All systems, including all subsystems, shall be tested in all operating modes prior to use and witnessed by the Commissioner. At least one phase of the test on each system shall employ the use of a cylinder of compressed nitrogen gas, or manufacturer's approved equal, to ascertain that all piping and nozzles are free of obstructions. (2) All systems (cylinders, release mechanisms, detectors, etc.) shall be inspected and tagged with the name of the individual conducting the inspection and the date of the inspection. All inspections and testing shall be conducted by the system manufacturer's authorized representative. The inspections shall be conducted every six months. J. Manufacturer's requirements. No part of the aforementioned methods of operation of installation are meant to alter the manufacturer's requirements. If there is a conflict between the requirements of this regulation and the manufacturer's requirements, each situation shall be considered on an individual basis.
Ask a question about Mount Vernon law
Corpus searches the Mount Vernon sections it holds and shows the ones that match, with their citations. Free, no sign-in.