§ 131-245: Piping and tubing.
A. All piping and tubing containing the refrigerant shall be supported by strong and durable material in such a manner as to prevent vibration and strains at joints and connections. B. Hard-drawn copper tubing will be accepted for air-conditioning systems of Class A, B, C or D when installed with the necessary sweat fittings and supported by strong, durable material in such a manner as to prevent vibration and strain at joints and connections. All soldered joints must be made with not less than 95-5 solder. C. Air-conditioning systems to which these provisions cannot be applied may be maintained and operated subject to such conditions as are deemed necessary by the Fire Commissioner. D. All refrigerant piping, tubing and fittings shall be of material suitable for the refrigerant intended and shall be able to withstand the minimum required test pressures as hereinafter provided in § 131-247. E. For systems of Class A, B, C or D, standard wall thickness pipe may be used where a test pressure of less than 300 pounds is required; and where the test pressures are in excess of 300 pounds, extra-heavy wall thickness pipe shall be used. If flanged fittings are used for pipe connections, they shall be of recessed gasket type. F. For systems of Class C or D, seamless copper or other suitable approved metal tubing of not less than 0.034 of an inch wall thickness and not exceeding 5/8 of an inch in diameter, and of corresponding greater wall thickness for larger diameters, may be used, provided the joints are sweated, brazed or flared. G. In Class C systems using seamless metal tubing for refrigerant lines and supplying two or more evaporators in two or more separate refrigeration spaces (termed "multiple systems"), the refrigerant lines if they extend between floors shall be enclosed in iron pipe or tubing or other metal sleeve enclosure. The enclosures may be of flexible metal at bends or terminals if not exceeding six feet in length and if rigidly fastened to connecting enclosure pipe. Enclosures shall be rigidly secured to the walls or other supports. H. Each vertical run of metal enclosure shall be sealed or plugged at its upper end with a material not affected by moisture or the temperature of the refrigerant lines. All refrigerant line joints shall be accessible. I. Service shutoff valves for the suction and liquid refrigerant lines shall be arranged with a handwheel or other means of ready operation and shall be located at the lower end of each riser. J. The use of a central refrigerating system using the direct method of refrigeration to individual refrigerators throughout a multiple dwelling is hereby prohibited. K. All drain, wastewater supply and illuminating gas connections shall be made to comply with all City ordinances and regulations. L. No water drain from any compressor, absorber or condenser shall be connected directly with any sewer, soil, waste or other plumbing pipe but must discharge over the surface of an open area, over a trapped, vented and water-supplied plumbing fixture or otherwise as directed by the appropriate City authority. M. Elevator, dumbwaiter or other shafts containing moving objects shall not be used for refrigerant lines.
Ask a question about Mount Vernon law
Corpus searches the Mount Vernon sections it holds and shows the ones that match, with their citations. Free, no sign-in.