§ 131-246: Safety devices.

A. Pressure-relief valves, pressure-limiting devices and rupture members shall be made of suitable materials for the refrigerant employed and shall be constructed and set to prevent the pressure exceeding the test pressures. B. No stop valve shall be located between a pressure-relief device or pressure-limiting device and the part of the system protected thereby unless two pressure-relief devices of required size are used and so arranged that only one pressure-relief device can be cut off for repair purposes at any one time. C. Class B systems in which no stop valves are used and in which the pressure will equalize throughout the system when the pressure imposing element is not in operation may be protected by only one pressure-relief device located on the high-pressure side. D. The low pressure side of a Class A ammonia system shall be provided with a hand operated valve for discharging the ammonia into water through a mixer to the sewer in case of emergency. E. The ammonia mixer shall be constructed of steel and shall be capable of withstanding a pressure of at least 50 pounds per square inch. F. No valve shall be located in the ammonia emergency discharge line except the manually operated valve discharging into the water and ammonia mixer, but there may be one stop valve located inside the building for repair purposes only. This valve shall be sealed open and labeled "keep open." G. The manually operated pressure-relief valve shall be located in a locked box which can be opened by members of the Bureau of Fire Prevention by means of a Fire Bureau key. The door of the box shall be on the public thoroughfare side of the building, in an easily accessible location and not less than 18 inches nor more than five feet above the sidewalk level. The box shall be permanently labeled, having letters of not less than one inch reading FOR FIRE BUREAU USE ONLY. The relief valve shall be labeled "ammonia." A sign shall be posted within the box reading DO NOT OPEN VALVE UNTIL WATER IS FLOWING. H. A single standard two-and-one-half-inch Fire Department connection shall be provided through which the necessary water may be supplied to the mixer. The Fire Department connection shall be located near the box and not less than 18 inches nor more than 24 inches above the sidewalk level and shall be permanently labeled, having letters not less than one-inch high reading TO AMMONIA MIXER. A check valve so set as to prevent gases from reaching the Fire Department connection shall be installed in the water line between the Fire Department connection and water and ammonia mixer. I. The Fire Department shall have sole use of the mixer and supply the necessary water. J. In systems using over 27,000 pounds of ammonia, there shall be provided one additional water and ammonia mixer for each 27,000 pounds of ammonia or fraction thereof so used in excess. K. The ammonia mixer and its connection for a Class A system shall conform to the diagram. L. The size of pressure-relief valves shall be as follows: Carbon Dioxide and Ethane Refrigerants | Other Refrigerants Capacity of System(pounds) | Number Required | Size(inches) | Number Required | Size(inches) Up to 1,000 | 1 | 1/2 | 1 | 1/2 1,001 to 1,800 | 1 | 1/2 | 1 | 3/4 1,801 to 3,000 | 1 | 1/2 | 1 | 1 3,001 to 5,250 | 1 | 1/2 | 1 | 1 1/4 5,251 to 7,500 | 1 | 1/2 | 1 | 1 1/2 7,501 to 13,500 | 1 | 1 | 1 | 2 13,501 to 27,000 | | | 2 | 2 M. Where rupture members are permitted and used, the equivalent area of the relief valve specified must be provided. N. Fusible plugs may be used on Class C and D systems. The free discharge opening shall be 1/16 of an inch in diameter and shall relieve the pressure at a temperature not exceeding 280° F. O. Every system using a water-cooled condenser with a pressure-imposing element which is capable of producing a pressure in excess of the test pressure shall be protected by a pressure-limiting device. P. Each compressor or generator of a Class A or B system shall be protected by a pressure-relief valve connected into the high-pressure side between the main top valve and the compressor or generator to relieve excessive pressure into the low-pressure side of the system but must at all times be relieved to atmosphere. Q. A rupture member may be substituted for the relief valve in carbon dioxide systems or systems operating below atmospheric pressure. R. Shell-type apparatus, such as liquid receivers, condensers, evaporators, liquid separators and absorbers of Class A and B systems, which can be shut off by stop valves, shall be equipped with a pressure-relief valve discharging as hereinafter provided. S. Class C and D systems so constructed that, when subjected to an abnormal outside temperature such as that generated in a fire, their walls may burst due to the expansion of the refrigerant, shall be protected by a pressure relief device. T. Where more than 50 pounds of ammonia is used in a Class A or B system, the discharge from relief valves shall be piped to the outside atmosphere as specified for Class A systems or to the low-pressure side as shown in diagrams or into a tank of water which shall be used for no purpose except ammonia discharges. At least one gallon of fresh water shall be provided for every pound of ammonia contained in the system. The water used shall be prevented from freezing without the use of salt or chemicals. The tank shall be substantially constructed of not less than 1/8 of an inch or No. 11 U.S. gauge iron. No horizontal dimensions of the tank shall be greater than 1/2 the height. The tank shall have a hinged cover, or if of the enclosed type, shall have a vent hole at the top. All pipe connections shall be through the top of tank only. The discharge pipe from the pressure valve shall discharge the ammonia in the center of the tank near the bottom. The tank shall be as securely supported as any other part of the system. There shall be no opening in the tank below the water level. U. In Class A and B systems using any refrigerant other than ammonia, the discharge from relief valves shall be to the atmosphere as specified for Class A ammonia systems. Carbon dioxide may be discharged into the room if same contains at least 10 cubic feet of capacity per pound of refrigerant used. V. Arrangements of pressure relief devices for Class A and B systems shall conform to the diagrams. W. Liquid level gauge glasses, except those of the bull's eye type, shall have automatic closing shutoff, and such glasses shall be adequately protected against injury by slotted metal casing. X. All refrigerating cabinets that are supplied by the remote system of refrigeration must be securely fastened to the floor or wall.

Ask a question about Mount Vernon law

Corpus searches the Mount Vernon sections it holds and shows the ones that match, with their citations. Free, no sign-in.