§ 224A-6 — Permitting requirements for Tier 1 solar energy systems

Code of the City of Mount Vernon, New York · Mount Vernon City Code § 224A-6

Corpus is an independent public-information project, not the official City of Mount Vernon website. Stable reference: corpuslaw.us/code/d2120752-dc84-476a-98ec-6f84b019ec3b

§ 224A-6: Permitting requirements for Tier 1 solar energy systems.

A. A Tier 1 solar energy system shall be permitted in all zoning districts in the City of Mount Vernon, subject to the conditions listed below for each type of Tier 1 solar energy system. The Building Department shall use the New York State Unified Solar Permit application and procedures in its review and issuance of a building permit for the installation of Tier 1 solar energy systems with a capacity of 25 kW or less. The Building Department shall use its standard building permit application and procedures in its review and issuance of a building permit for the installation of Tier 1 solar energy systems with a capacity greater than 25 kW. All Tier 1 solar energy systems shall be exempt from site plan review and approval by the Planning Board. Tier 1 solar energy systems shall also be exempt from certificate of appropriateness review and approval by the Architectural Review Board. Energy generated from a Tier 1 solar energy system shall be consumed on-site, and shall not be generated for the purpose of supplying energy to the electrical grid, except in instances where surplus energy only, beyond the normal demands of the site, is produced. (1) Roof-mounted solar energy systems. (a) A roof-mounted solar energy system shall be permitted pursuant to the issuance of a building permit from the City of Mount Vernon Building Department. (b) All roof-mounted solar energy systems shall comply with the following: [1] Solar panels on pitched roofs shall be mounted with a maximum distance of eight inches between the roof surface and the highest edge of the system. [2] Solar panels on pitched roofs shall be installed parallel to the roof surface on which they are mounted or attached. [3] Solar panels on pitched roofs shall not extend higher than the peak of the roof surface on which they are mounted or attached. [4] Solar panels on flat roofs shall not extend above the top of the surrounding parapet, or more than 24 inches above the flat surface of the roof, whichever is higher. (c) All roof-mounted solar energy systems shall incorporate, to the extent feasible, the following design requirements: [1] If solar exposure options exist, solar panels should not be placed on the front street facing portion of the roof. [2] Solar panel groups should be arranged or oriented in the same direction (either all "landscape" or all "portrait"). [3] Solar panels should be arranged or grouped in complete rectangles. Staggered or stepped solar panel arrangements should be avoided. [4] The colors of solar panels and frames should not contrast and should reasonably match the color of the roof. (d) Glare: All solar panels shall have anti-reflective coating(s). (e) Height: All roof-mounted solar energy systems shall be subject to the maximum height regulations specified for principal and accessory buildings within the underlying zoning district. (f) Equipment: With the exception of solar panels, all equipment associated with roof-mounted solar energy systems, including, but not limited to, controls, energy storage devices, heat pumps, exchangers, or other hardware or equipment necessary for the process by which solar radiation is converted into electricity, shall be screened from view and shall not be located in any required front, side or rear yard setback. (2) Building-integrated solar energy systems. (a) A building-integrated solar energy system shall be permitted pursuant to the issuance of a building permit from the City of Mount Vernon Building Department. (b) A building-integrated solar energy system, as part of the principal or accessory building, shall comply with all applicable setback regulations of the zoning district within which it is situated. (c) All equipment associated with building-integrated solar energy systems, including, but not limited to, controls, energy storage devices, heat pumps, exchangers, or other hardware or equipment, shall be located within the principal or accessory structure it serves. (3) Solar canopies. (a) A solar canopy shall be permitted in all nonresidential districts pursuant to the issuance of a building permit from the City of Mount Vernon Building Department. (b) Glare: All solar panels shall have anti-reflective coating(s). (c) Setbacks: A solar canopy, as part of a principal building, accessory building, or freestanding, shall comply with all applicable setback regulations of the zoning district within which it is situated. (d) Height: No solar canopy can exceed 25 feet. (e) Applicants for a permit to construct a solar canopy shall submit all studies as required by the Building Department.

Ask a question about Mount Vernon law

Corpus searches the Mount Vernon sections it holds and shows the ones that match, with their citations. Free, no sign-in.