For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

pt. 2 — Water Supply Systems

Municipal Code of the City of White Plains, New York (Codified through Ordinance of October 5, 2026. (Supp. No. 79, Update 2)) · White Plains Supplemental Building and Fire Codes ch. 7, pt. 2

Corpus is an independent public-information project, not the official City of White Plains website. Stable reference: corpuslaw.us/code/4f8ff72d-e617-42e3-aadb-1c094532cc3f

Part 2. - Water Supply Systems

a. Domestic & Fire Service Water (Single vs. Dual Source). (1) Single Supply. For construction of a new building, expansion of an existing building, or change from one use to a more critical use the domestic and fire protection water to the building (off the public water main) need only be a single water service where the building "use" is not determined to be a critical "use". The service size shall be based upon hydraulic calculations of both the total demand of the domestic and fire suppression requirements of the building with a minimum diameter size of two inches. If the calculations dictate a pipe size that is greater in diameter, than the available street main then a dual supply as described under Item 2 shall be provided. (2) Dual Supply. For construction of a new building, expansion of an existing building, or change from one use to a more hazardous use the domestic and fire protection water service to the building (off the public water main) shall consist of two pipes of equal size with a full interconnect inside the building where the building's "use" is determined to be a critical "use". The service size shall be based upon hydraulic calculations of both the total demand of the domestic and fire suppression requirements of the building with a minimum diameter of two inches. "Critical" uses shall include, but not be limited to: — Handling and storage of flammable liquids or gases. — Hospitals, nursing homes, infirmaries, clinics, mental hospitals etc. — Assisted living facilities, retirement homes, etc. — Multifamily residential buildings greater than three stories. — Other institutional uses as deemed by the Commissioner. Determinations as to the need for dual services, based on the degrees of criticality, will be made by the Building Department on a case-by-case basis. Where provided, separate services are the domestic and fire service lines shall be a minimum of six feet apart. The connections from each "water service" supplying domestic and fire suppression requirements shall be equipped with approved backflow prevention devices and installed within the building proper. Refer to Figure "A" for a schematic detail of a dual service installation. GRAPHIC UNAVAILABLE: Figure A b. Water Supply Tanks. (1) Special Approval. Water supply tanks, other than domestic hot water tanks, shall not be permitted, unless where approved by the Commissioner of Building for conditions where supply and booster pumps are not functionally feasible. If approved, erection of tanks and tank structures shall be in accordance with drawings prepared by a licensed professional engineer (or registered architect) and shall be subject to the review and approval of the Department of Building. c. Water Supply Piping Installation. (1) Water Service Pipe. Water service pipes shall be installed in accordance with the rules and regulations of the Commissioner. Connections to the street main shall be in compliance with the rules and regulations of the Department of Public Works of The City of White Plains. (2) Sizing the Water Supply System. (i) Water Service Pipe. The water service pipe shall be of sufficient size to furnish an adequate supply of water to meet the requirements of the building at peak demand. No water service pipe shall be smaller than one inch nominal size, except that where direct supply flush valves are supplied at pressure from the water service pipe, such pipe shall be at least one and one-fourth inch nominal size. d. Methods for Disinfecting Potable Water Supply System. (1) As part of the chlorination of the overall potable water supply system of a building, the plumber of record for such system shall also chlorinate all fire standpipes, combination risers and automatic sprinkler systems within said building. The installer of the automatic sprinkler system shall provide the necessary fittings for such chlorination. All chlorination shall undergo bacteriologic testing by an independent testing laboratory and shall be certified in writing.

Ask a question about White Plains law

Corpus searches the White Plains sections it holds and shows the ones that match, with their citations. Free, no sign-in.