pt. 1 — General Requirements
Municipal Code of the City of White Plains, New York (Codified through Ordinance of October 5, 2026. (Supp. No. 79, Update 2)) · White Plains Supplemental Building and Fire Codes ch. 7, pt. 1
Corpus is an independent public-information project, not the official City of White Plains website. Stable reference: corpuslaw.us/code/7a04c2ba-77a2-4b64-8902-3051df8fd80a
Part 1. - General Requirements
a. New Plumbing and Gas Piping Systems. This code in conjunction with the Plumbing and Fuel Gas Codes of the State of New York shall apply to plumbing and gas piping systems and to parts thereof, which are hereafter installed in the City of White Plains. b. Existing Plumbing and Gas Piping Systems. (1) General. This code shall also apply to the following existing plumbing and gas piping systems: (i) Plumbing and gas piping systems in a building hereafter occupied for occupancies or uses other than those for which it was occupied when this code became effective. (ii) Plumbing and gas piping systems where the extent of replacements or repairs exceeds 50 percent of the total length of piping in the existing system. (2) Addition or Alteration. (i) Any addition or alteration, regardless of cost, made to a plumbing or gas piping system shall be made in conformity with applicable regulations of this Code. (ii) Where additions or alterations subject parts of existing systems to loads exceeding those permitted herein, such parts shall be made to comply with this Code. (3) Minor Repairs or Replacements. Minor repairs or replacements of any existing system may be made in the same manner and arrangement as in the existing system provided such repairs or replacements are made in a safe and sanitary manner. (4) Existing Uses Continued. Except as otherwise provided herein, nothing in this code shall require the removal, alteration, or abandonment of, nor prevent continued use of an existing plumbing or gas piping system. c. Maintenance. Plumbing and gas piping systems subject to this Code shall be maintained in a safe and sanitary condition in conformity with the provisions of this Code. d. Workmanship. Workmanship shall conform to generally accepted good practice. e. Unlawful Acts. It shall be unlawful to install, extend, alter, repair, or maintain plumbing and gas piping systems in or adjacent to buildings except in conformity with this Code. f. Razing or Removing Structures. When any building is removed or any drainage, sewer, water or gas system is dismantled, before any drainage or plumbing is disturbed or removed, the drainage, sewer, water and gas connections shall be properly disconnected and sealed and inspected in the presence of a plumbing inspector of this city. g. Permits. (1) Permits Required. (i) The following systems shall only be installed under a plumbing permit and only by a Licensed Master Plumber: Sanitary drainage systems, potable water systems, medical gas piping systems; central evacuation (vacuum) piping systems within medical centers and solar energy systems for domestic hot water supply. (ii) Except for the initial connection to a potable water supply (down stream of the backflow device) and the final connection that discharges indirectly into a public or private disposal system the following shall be understood to be components of an automatic sprinkler system and may be installed without a plumbing permit and by other than a licensed master plumber: All piping, tubing, appurtenances and equipment connected or pertaining to such a system, including without limitation sprinkler laterals, sprinkler heads, private overhead and underground water service laterals, fire hydrants and hydrant mains, sprinkler risers, combination risers, combination fire standpipes, hose and fire department connections, sprinkler tank heaters, air lines, thermal systems, gauges, valves, tanks and pumps, beginning at the point where the water is limited to use exclusively for fire protection by installation of an approved backflow prevention device within the building proper. h. Applications. (1) Application for any installation, repair or alteration to any plumbing or gas piping system shall be filed with the Commissioner, on forms furnished by the Commissioner, and shall contain a general description of the proposed work and its location, the type of occupancy and such other pertinent information as may be required. (2) Duplicate drawings and descriptions for all plumbing, drainage, and gas piping shall be properly filed by the owner or agent. The plans must be drawn to scale, or they must be prints of such scaled drawings, and shall consist of such floor plans and sections as may be necessary to show clearly all plumbing and gas piping work to be done, and must show partitions and methods of ventilating water closet compartments. (3) Plumbing, drainage, and gas piping shall not be commenced or proceeded with until said drawings and descriptions shall have been so filed and approved by the Commissioner. (4) No modification of the approved drawings and descriptions will be permitted unless an amendment to the original drawings and descriptions, covering the proposed change or changes is filed with and approved by the Commissioner. (5) Minor repairs or alterations of plumbing, drainage, or gas piping systems may be made without filing drawings and descriptions but such repairs or alterations shall not be construed to include cases where new vertical lines or horizontal branches of soil, waste, or vent pipes are proposed to be used. Notice of such minor repairs or alterations shall be given to the Commissioner and approval of the repair or alteration shall be obtained before the same are commenced and the work shall be done in accordance with the rules and regulations of this Code. (6) Where repairs or alterations, ordered by the Board of Health for sanitary reasons, including cases where new vertical or horizontal lines of soil, waste, vent or gas pipes are proposed to be used or old ones replaced, drawings and descriptions must be filed with and approved by the Commissioner before said repairs or alterations shall be commenced or proceeded with. (7) Reserved. (8) Notices must be given to the Commissioner by the plumber when any work is begun, and at such times as the work is ready for mandatory inspections. i. Fees. Refer to Section BCAE Subsection r. j. Plumbers. (1) No person, corporation or co-partnership other than the one licensed by the Westchester County Board of Plumbing Examiners [registered with the Commissioner as required by this section] shall be allowed to install plumbing or gas piping in any building or make connections with any sewer, drain, soil or waste pipe or to any pipe connected therewith, or to carry on or engage in the plumbing business within the City of White Plains. (2) No person, corporation or co-partnership registered as provided in this section, shall for the benefit of any person engaged in the plumbing business who is not registered, apply for, receive or make use of, any permit granted to him by reason of being so registered. (3) The licensed master plumber shall be personally responsible for the proper supervision and layout work for any plumbing work for which he has made application. All workmen engaged by said licensed master plumber for installation of any plumbing work, including site utility sanitary and potable water systems, must be on such licensed master plumber's own payroll and covered by the master plumber's own Workmen's Compensation and Disability Insurance Coverages.
Ask a question about White Plains law
Corpus searches the White Plains sections it holds and shows the ones that match, with their citations. Free, no sign-in.
