Part 4. - Drainage and Vent Systems

a. In buildings in which plumbing fixtures are installed, a sanitary drainage system shall be provided for conveying sewage from the fixtures by gravity to a public sanitary sewer system except as otherwise permitted herein. (1) A septic tank will be permitted only after an applicant has shown to the satisfaction of the Commissioner that its use is necessary and that the soil absorption rate and conditions at the site and adjacent area are safe and adequate according to standards prescribed by the Westchester County Department of Health or by the Commissioner. Every such applicant shall first submit to and file with the Commissioner a recent verified report from an approved testing expert showing satisfactory soil absorption rate and absence of hazardous conditions at the proposed site and adjacent area. (2) Private sewage systems shall be constructed and maintained in strict compliance with state and county health department codes, rules and regulations and with any more exacting rules and regulations which the Commissioner is hereby authorized to adopt and promulgate in the interest of public safety, health and general public welfare, and as he may be guided by standards provided in any other approved plumbing codes, and amendments or revisions thereof. (3) Every owner of property in which a septic tank is permitted shall be deemed to and shall agree that upon construction and installation of a public sewer in a public street or easement area abutting the applicant's property pursuant to the provisions of the City charter, local laws or ordinances of The City of White Plains such property shall bear its proportionate assessment for such public sewer system whether or not a sewer connection thereto shall be ordered by the common council. Upon the construction of such public sewer and the order of the common council to connect thereto, whenever deemed expedient, the owner and occupant of premises on which a cesspool, privy vault or septic tank is located shall have the same emptied, cleaned, disinfected and filled with fresh earth and shall have a sewer connection made as prescribed in this code. b. Building Sewers. Building sanitary sewers shall be a minimum of four inches in diameter. c. Building Traps and Fresh Air Inlets. (1) Building (House) Traps. Building (House) traps shall be required in the building sanitary (house) drain for all new systems. When the plumbing system of any existing building is altered by the addition of new soil, waste or vent lines and no house trap and fresh air inlet exists on the house drain, same shall be provided at the time of alteration. (2) Building Trap Cleanouts. Building traps shall be provided with two brass cleanout plugs. Such plugs shall be of the same size as the trap, for traps up to four inches in size, and shall be at least four inches in size for larger traps. Cleanout plugs shall be located at the trap so as to provide access for cleaning the trap interior and for rodding upstream and downstream from the trap. Cover screws shall be set with graphite paste. (3) Fresh Air Inlets. Every sanitary or combined building drain equipped with a building (house) trap, sewage sump, ejector, receiving tank oil separator, or similar equipment shall be provided with a fresh air inlet pipe connected to the building drain in accordance with The New York State Plumbing Code. d. Methods for Handling Drainage Below Sea Level. Drainage from parts of drainage systems which cannot drain by gravity into the sewer shall be disposed of through subbuilding (subhouse) drainage systems and shall be discharged into the building gravity drainage system by automatic equipment or by another approved method. Drainage and vent piping of sanitary subbuildings drainage systems shall be installed in the same manner as for gravity systems, except that a fresh air inlet shall be installed between trap and sump and the building drains of such systems shall drain into airtight and vented sumps, ejectors, or receiving tanks from which the sewage shall be discharged as required herein. Sumps, ejectors and receiving tanks which receive only clear water drainage and from which sewage is excluded, need not be airtight and vented. (Refer to Figure B) GRAPHIC UNAVAILABLE: Figure B

Ask a question about White Plains law

Corpus searches the White Plains sections it holds and shows the ones that match, with their citations. Free, no sign-in.