50.81 - Discharge criteria for fats, oils and grease.
A. All wastewater that is discharged containing fats, oils and grease shall be discharged into a properly maintained and functioning grease trap and/or grease interceptor. B. The director may require any discharger that violates any of the provisions of this article or who discharges, could potentially discharge, or cause a discharge of fats, oils and grease that causes damage to or impairs the City's wastewater disposal system, to do any of the following: 1. Install an approved grease interceptor; or 2. Clean a grease interceptor at a frequency determined by the director; or 3. Replace an existing grease trap and/or grease interceptor with an approved grease interceptor; or 4. Provide any information necessary to facilitate the enforcement of this section. C. If the discharger demonstrates that the installation of a grease interceptor is impractical to the satisfaction of the director, the director may do any of the following: 1. Approve installation of a grease interceptor that is smaller or otherwise varies from the standard construction drawings; 2. Approve installation of a grease trap; or 3. Waive the requirement to install a grease interceptor. D. The design of a grease interceptor shall comport with the requirements shown on the City of Akron Standard Construction Drawings. E. Where fats, oils and grease are a byproduct of food preparation and/or cleanup, these materials shall be recycled or disposed of in accordance with all applicable laws. F. None of the following agents shall be placed directly into a grease trap or grease interceptor, or into any drain that leads to the grease trap or grease interceptor: 1. Emulsifiers, de-emulsifiers, surface active agents, enzymes, degreasers, or any product that will liquefy grease trap or interceptor wastes; 2. Any substance that may cause excessive foaming in the sewer system; or 3. Any substance capable of passing the solid or semi-solid contents of the grease trap or interceptor to the sewer system. G. Influent wastewater entering grease traps and grease interceptors shall not exceed 140 degrees Fahrenheit (140° F). The temperature at the flow control device inspection port shall be considered equal to the influent temperature. H. Toilets, urinals, and other similar fixtures shall not be plumbed to a grease trap or grease interceptor. I. Waste shall only enter the grease trap or grease interceptor through the inlet flow control device. J. Food waste grinders, where installed, shall be plumbed through a solids interceptor to a grease trap or grease interceptor. K. Grease trap and grease interceptor maintenance shall satisfy the following: 1. All dischargers of fats, oils and grease are responsible for maintaining the grease traps and grease interceptors in continuous proper working condition in accordance with the manufacturer's operation and maintenance manual. All dischargers of fats, oils and grease are also responsible for inspecting, repairing, replacing, or installing apparatus and equipment as necessary to ensure proper operation and function of grease traps and grease interceptors, and compliance with discharge limitations at all times. All dischargers of fats, oils and grease and their employees must have knowledge of any grease trap and grease interceptor's location, usage and maintenance schedule. 2. It shall be unlawful for a discharger of fats, oils and grease to allow fats, oils and grease waste to be removed from its premises by a transporter who does not have all applicable federal, state, or local permits or registrations, including any permit required by the Summit County Combined General Health District. 3. If a discharger of fats, oils and grease utilizes a grease transport/disposal company to remove the grease from the grease interceptor or grease trap, a "Grease Hauler Manifest Form" must be kept on file at the facility from which the grease is removed. A Grease Hauler Manifest Form is available from the Akron Sewer Maintenance Division. The grease transport/disposal company shall provide a certificate of insurance, certificate of assurance, and certificate of indemnification to the owner or operator of the FSE. 4. A discharger of fats, oils and grease must maintain any grease trap and/or grease interceptor maintenance records on site for three years. A discharger of fats, oils and grease shall maintain adequate documentation that the grease trap and/or grease interceptor is appropriately cleaned and inspected. 5. A FSE which discharges fats, oils and grease shall clean the grease trap and/or grease interceptor as follows: (a) Any grease interceptor that is in active use shall be cleaned at least once every three months. (b) Any grease trap that is in active use shall be cleaned at least once every week. (c) The cleaning frequency may be decreased, with the approval of the Service Director, if the owner or operator of the FSE is able to provide evidence it has been able to operate longer without impairment to the operation of facility's sewer lateral and the public sewer system. (d) The Director of Public Service may specify more frequent cleaning when the cleaning frequencies are determined by the Director to be inadequate.
(Ord. 412-2012; Ord. 160-2019)
Ask a question about Akron law
Corpus searches the Akron sections it holds and shows the ones that match, with their citations. Free, no sign-in.