For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 52.03 — General requirements

Code of Ordinances, City of Dayton, Ohio (Supp. No. 36: codified through Ordinance No. 32173-25, passed December 31, 2025) · Dayton City Code § 52.03

Corpus is an independent public-information project, not the official City of Dayton website. Stable reference: corpuslaw.us/code/311cae3c-3840-437e-b164-c4fb7aa1609c

Sec. 52.03. - General requirements.

I. Waste disposal. No person shall place, deposit, or permit to be deposited in any non-sanitary manner on public or private property within the city, or in any area under the jurisdiction of said city, any human or animal excrement, garbage, or other objectionable waste. No person shall discharge wastewater to any outlet except in compliance with federal and state NPDES permit requirements. II. Prohibited discharge standards. (A) General prohibitions. No user shall introduce or cause to be introduced into the POTW pollutant or wastewater that cause pass through or interference. These general prohibitions apply to all users of the POTW whether or not they are subject to categorical pretreatment standards or any other national, state, or local pretreatment standards or requirements. The Director may reject any wastewater that will create hazards or have deleterious effects on the POTW. (B) Specific prohibitions. No person shall discharge or cause to be discharged to the POTW any substances, materials, waters, or wastes in such quantities or concentrations that in whole or in part: (1) Create a fire or explosion hazard including, but not limited to, gasoline, benzene, naphtha, fuel oil, wastestreams with a closed cup flashpoint of less than 60 degrees Celsius (140 degrees Fahrenheit) using the test method specified in 40 CFR 261.21, or other flammable or explosive liquid, solid, or gas; (2) Contain corrosive properties causing damage or hazard to structures, equipment, or personnel of the wastewater facilities; however, in no case shall discharges have a pH lower than 6.0 or greater than 12.0 unless the Director orders specific alternate limitations or conditions. pH shall be determined by analytical methods defined by 40 CFR Part 136 or alternate methods approved by the Director; (3) Solid or viscous pollutants in amounts that will cause obstruction to the flow in the POTW resulting in interference; but in no case solids greater than one-half inch in any dimension; (4) Pollutants, including oxygen-demanding pollutants (BOD, COD, etc.), released in a discharge at a flow rate and/or pollutant concentration that, either singly or by interaction with other pollutants, will cause interference with the POTW; (5) Contain heat in amounts that will accelerate the formation of excessive amounts of hydrogen sulfide in the sanitary sewer, inhibit sampling efforts, endanger wastewater treatment facility personnel, or inhibit biological activity in the wastewater treatment facilities. A discharge of wastewater in excess of 60 degrees Celsius (140 degrees Fahrenheit) may be prohibited by the Director. In no case shall a discharge of wastewater cause the temperature of the influent to the wastewater treatment facility to exceed 40 degrees Celsius (104 degrees Fahrenheit); (6) Contain any type of oils, fat, or grease that may cause or contribute to the obstruction of the flow in sewers or that may cause or contribute to interference with the operation or performance of, or pass-through, the wastewater facilities; and, at the discretion of the Director, water or wastes containing fats, wax, grease, or oils regardless of origin, and whether emulsified or not, in excess of 100 mg/L, as determined using methods specified by 40 CFR 136; (7) Contain materials that may result in the presence of toxic gases, vapors, or fumes within the wastewater facilities or that may cause acute worker health and safety problems or that may cause violations of applicable occupational health and safety regulations; (8) Trucked or hauled pollutants, including septage and industrial waste, unless authorized by the Director, and at discharge points designated by the Director; (9) Noxious or malodorous liquids, gases, solids, or other wastewater that, either singly or by interaction with other wastes, are sufficient to create a public nuisance or a hazard to life, or to prevent entry into the sewers for maintenance or repair; (10) Contain any odor or color producing substances exceeding concentration limits or other applicable standards that are established by the Director for the purposes of meeting the city's NPDES permit; (11) Contain radioactive wastes in quantities prohibited by applicable state and federal regulations, or that, in the determination of the Director, will interfere with operation of the wastewater facility, or the safety of the workers or public, or the marketability or safety of sewage sludge and biosolids; (12) Any runoff from roof, foundation, areaway, parking lot, roadway, or other surface water or groundwater or non-contact cooling water. The Director may approve the discharge of such water only when he determines that the quantity and quality of the discharge will not unreasonably burden the capabilities of the wastewater facility and no alternate method of disposal or reuse is reasonably available, or to mitigate an environmental risk or health hazard. All such approved discharges shall be flow measured by the discharger, using a measuring device or other method approved by the Director, and shall be subject to the city's applicable schedules of sewer rates and charges; (13) Any sludges, screenings, or other residues from the pretreatment of industrial or commercial wastes or from industrial or commercial processes, except as authorized by the Director; (14) Wastewater causing, alone or in conjunction with other sources, the treatment plant's effluent to fail a toxicity test; (15) Detergents, surface-active agents, or other substances in amounts that cause excessive foaming in the POTW, as determined by the Director; (16) Any liquid, solids, or gases that by reason of their nature or quantity are, or may be, sufficient either alone or by interaction with other substances to cause fire or explosion or be injurious in any other way to the POTW or to the operation of the POTW. At no time shall two successive readings on an explosion meter, at the point of discharge into the system (or at any point in the system), be more than five percent nor any single reading over ten percent of the lower explosive limit (LEL) of the meter; (17) Animal guts or tissues, paunch manure, bones, hair, hides or fleshings, entrails, whole blood, feathers, ashes, cinders, sand, stone or marble dusts, metal, glass, straw, shavings, grass clippings, rags, waste paper, wood, plastics, gas, tar asphalt residues, residues from refining or processing of fuel or lubricating oil, mud, or glass grinding or polishing wastes, or any garbage that has not been properly shredded, except as specifically authorized by the Director; (18) Cause the city to violate any limits in the city's NPDES permit, or any requirement of the permit, or otherwise pass-through or interfere with the city's wastewater treatment facility, or significantly contribute to any such violation, pass-through, or interference; (19) The contents of any tank or other vessel owned or used by any person in the business of collecting or pumping sewage, effluent, septage, or other wastewater unless said person has first obtained testing and approval as may be generally required by the city and paid all fees assessed for the privilege of said discharge; (20) Contain polychlorinated biphenyls, or isomers thereof: in any quantity or concentration above method detection limits delineated in 40 CFR Part 136 or that are detected by any other method; (21) Any hazardous or dangerous wastes as defined in rules published by the State of Ohio (ORC 3734/3745) and/or in EPA rules 40 CFR Part 261; (22) Persistent pesticides and/or pesticides regulated by the Federal Insecticide Fungicide Rodenticide Act (FIFRA); (23) Any slug load; or (24) Cause the city's effluent or residues, biosolids, sludges, grit, or scums, to be unsuitable for reclamation and reuse or interferes with the sludge, grit, and scum disposal practices. (C) Pollutants, substances, or wastewater prohibited by this section shall not be processed or stored in such a manner that they are likely to be discharged to the POTW unless the user has in place a spill prevention control and containment (SPCC) plan/slug control plan that has been reviewed and approved by the Director. (D) Any removal of manhole lids, or other access to the wastewater facilities for the purpose of discharging wastes at times and/or locations other than those designated by the Director, or without the expressed permission of the Director, shall be considered a violation and shall be subject to enforcement action including assessments and/or penalties. III. Federal categorical pretreatment standards. The National Categorical Pretreatment Standards found at 40 CFR Chapter I, Subchapter N, Parts 405-471 are incorporated herein by reference as if set forth in full in this chapter. (A) Where a categorical pretreatment standard is expressed only in terms of either the mass or the concentration of a pollutant in wastewater, the Director may impose equivalent concentration or mass limits in accordance with 40 CFR 403.6(c)(5) for equivalent mass-based limits or 40 CFR 403.6(c)(6) for equivalent concentration-based limits. (B) When wastewater subject to a categorical pretreatment standard is mixed with wastewater not regulated by the same standard, the Director shall impose an alternate limit using the combined wastestream formula in 40 CFR 403.6(e). (C) A user may obtain a variance from a categorical pretreatment standard if the user can prove, pursuant to the procedural and substantive provisions in 40 CFR 403.13, that factors relating to its discharge are fundamentally different from the factors considered by EPA when developing the categorical pretreatment standard. (D) A user may obtain a net gross adjustment to a categorical standard in accordance with 40 CFR 403.1 5. IV. State requirements. State requirements and limitations on discharges to the POTW shall be met by all users that are subject to such standards in any instance in which they are more stringent than federal requirements and limitations, or those in this chapter or other applicable laws. V. Local limits. (A) The Director shall, from time to time, adopt, revise, or rescind local limits based upon the exercise of scientific and technical discretion as he or she deems appropriate to prevent pass-through; interference; accumulation of pollutants in the wastewater treatment sludge or biosolids; or detriment to worker health and safety. All persons discharging to wastewater facilities owned by or under the jurisdiction of the city shall meet the applicable local limits as developed by the Director and set forth in the document "Local Limits for the Discharge of Wastewater under the Industrial Pretreatment Program, Division of Water Reclamation, City of Dayton" (previously titled "Local Limits for the Discharge of Wastewater under the Industrial Pretreatment Program, Division of Wastewater Treatment, City of Dayton") unless otherwise authorized under the provisions of this chapter. The Director shall give written notice of any new, revised, or rescinded local limits to each significant industrial user known to be affected by the limit and shall publish notice of the new or revised local limits in a newspaper of general circulation at least 30 days prior to the effective date of the new or revised local limits. Prior to the effective date of such new or revised local limits, the limits previously established by ordinance or the Director shall remain in effect. (B) Where specific prohibitions or limits on pollutants or pollutant parameters are developed), such limits shall be deemed local limits and pretreatment standards. (C) Users that are required to also meet a federal categorical pretreatment standard shall meet the stricter between the local limit and the federal categorical pretreatment standards referred to in subsection III of this section. (D) Best management practices (BMPs) may be developed as a local limit and must also be incorporated in the industrial wastewater discharge permit or applicable control document and shall be considered a local limit and a pretreatment standard. VI. City's right of revision. The Director reserves the right to establish, by ordinance or in wastewater discharge permits, more stringent standards or requirements on discharges to the POTW. Additionally, by the authority granted by CFR Part 403.7, the Director may apply for and obtain authorization from the EPA to revise discharge limitations for those substances listed in the federal categorical pretreatment standards for which consistent removal occurs in the wastewater treatment facilities. VII. Special agreement. The Director reserves the right to enter into special agreements with users setting out special terms under which they may discharge to the POTW. In no case will a special agreement waive compliance with a categorical pretreatment standard or federal pretreatment requirement. However, the user may request a net gross adjustment to a categorical standard in accordance with 40 CFR 403.15. They may also request a variance from the categorical pretreatment standard from the approval authority in accordance with 403.13. VIII. Dilution. A user shall not increase the use of process water to avoid or reduce the assessment of an extra-strength surcharge, or in any way attempt to dilute a discharge, as a partial or complete substitute for adequate treatment to achieve compliance with an applicable pretreatment standard or requirement unless expressly authorized by an applicable pretreatment standard or requirement. The Director may impose mass limitations on users that he believes may be using dilution to meet applicable pretreatment standards or requirements, or in other cases when the imposition of mass limitations is appropriate. IX. Pretreatment facilities. (A) General: Users shall provide all known, available, and reasonable methods of prevention, control, and treatment (AK.ART) as required to comply with this chapter and shall achieve compliance with all applicable pretreatment standards and requirements set out in this chapter within the time limitations specified by the EPA, the state, or the Director, whichever is more stringent. (B) Any facilities required to pre-treat wastewater to a level acceptable to the Director shall be provided, operated, and maintained at the user's expense. (C) In addition, the Director may establish Best Management Practices (BMPs) for particular groups of users. These BMPs may include, but are not limited to types or methods of pretreatment technology to be used, methods of source control, minimum maintenance requirements, dragout prevention practices, spill prevention practices, or other requirements as deemed necessary. BMPs may be developed as a local limit and if so, shall be incorporated in the industrial wastewater discharge permit or alternate control document. Industrial users with applicable standards that require compliance with a BMP or a pollution prevention alternative shall submit documentation to determine compliance with the standard when submitting baseline or periodic compliance reports. (D) Detailed plans describing such facilities and operating procedures shall be submitted to the Director for review, and shall be acceptable to the Director before such facilities are constructed. The review of such plans and operating procedures shall in no way relieve the user from the responsibility of modifying such facilities as necessary to produce a discharge acceptable to the Director under the provisions of this chapter. (E) Within 90 days after the completion of the wastewater pretreatment facility, the discharger shall furnish as-built drawings and its operations and maintenance procedures. Any subsequent significant changes in the pretreatment facility or method of operation shall be reported to and approved by the Director prior to the initiation of the changes. (F) New sources, and new users determined to be SIUs shall have pretreatment facilities installed and operating prior to discharge, if required. (G) Dischargers who operate automatic and coin-operated laundries, car washes, filling stations, commercial garages or similar businesses having any type of washing facilities (including pressure washing and steam cleaning) or any other dischargers producing grit, sand, oils, lint, or other materials that have the potential of causing partial or complete obstruction of the building side sewer or other areas in the POTW shall, upon order of the Director, install approved interceptors, oil/water separators, or tanks in accordance with specifications adopted by the city such that excessive amounts of oil, sand and inert solids are effectively prevented from entering the POTW. (H) All pretreatment facilities, including grease interceptors, oil/water separators, settling tanks and grit traps shall be properly installed, maintained, and operated by the discharger at his or her own expense. The installation shall be kept in continuous operation at all times, and shall be maintained to provide efficient operation. Cleaning shall be performed by a service contractor qualified to perform such cleaning, or in a manner approved by the Director. All material removed shall be disposed of in accordance with all state and federal regulations. Records and certification of maintenance shall be made readily available to the Director for review and inspection, and shall be maintained for a minimum of three years. (I) If a failure to maintain settling tanks, grease traps and/or interceptors, or oil/water separators results in partial or complete blockage of the building sewer, private sewer system discharging to the city sewer system, or other parts of the city sewer system, or adversely affects the treatment or transmission capabilities of the POTW, or requires excessive maintenance by the city, or poses a possible health hazard, the discharger responsible for the facilities shall be subject to the remedies herein, including cost recovery, enforcement, violation assessments, and penalties. X. Additional pretreatment measures. (A) Whenever deemed necessary, the Director may require users to restrict their discharge during peak flow periods, designate that certain wastewater be discharged only into specific sewers, relocate and/or consolidate points of discharge, separate sewage wastestreams from industrial wastestreams, and such other conditions as may be necessary to protect the POTW and determine the user's compliance with the requirements of this chapter. (B) When determined necessary by the Director, each user discharging into the POTW, shall install and maintain, on his or her property and at his or her expense, a suitable storage and flow-control facility to insure equalization of flow. The Director may require the facility to be equipped with alarms and a rate of discharge controller, the regulation of which shall be determined by the Director. A wastewater discharge permit may be issued solely for flow equalization. (C) Grease, oil, and sand interceptors shall be provided when, in the opinion of the Director, they are necessary for the proper handling of wastewater containing excessive amounts of fats, oils, and grease, or sand; except that such interceptors shall not be required for individual dwelling units or any private living quarters. All interception units shall be of type and capacity approved by the Director and shall be so located to be easily accessible for cleaning and inspection. Such interceptors shall be inspected, cleaned, and repaired regularly, as needed, by the user at his or her expense. (D) Users with the potential to discharge flammable substances may be required to install and maintain an approved combustible gas detection meter. XI. Deadline for compliance with applicable pretreatment requirements. (A) Compliance by existing sources (categorical users) covered by categorical pretreatment standards shall be within three years of the date the standard is effective unless a shorter compliance time is specified in the appropriate standard. The director shall establish a final compliance deadline date for any categorical user when the local limits for said user are more restrictive than EPA's Categorical Pretreatment Standards. The Director may establish a final compliance deadline date for any existing user not covered by categorical pretreatment standards. (B) New source dischargers, and "new users" that are determined to be SIUs, are required to comply with applicable pretreatment standards within the shortest feasible time (not to exceed 90 days from the beginning of discharge). New sources, and "new users" that are determined to be SIUs, shall install and have in operating condition, and shall "start-up" all pollution control equipment required to meet applicable pretreatment standards before beginning to discharge. (C) Any wastewater discharge permit issued to a categorical user shall not contain a compliance date beyond any deadline date established in EPA's Categorical Pretreatment Standards. Any other existing user that is considered to be an SIU, or a categorical user that shall comply with a more stringent local limit, which is in non-compliance with any local limits shall be provided with a compliance schedule to insure compliance within the shortest time feasible. XII. Accidental discharge/slug control plans. (A) The Director shall evaluate whether each SID needs an accidental discharge/slug control plan at least once during the term of each significant industrial user's industrial wastewater discharge permit or applicable control document or within one year of being identified a significant industrial user. The Director may require any user to develop and implement an accidental discharge/slug control plan. Where deemed necessary by the Director, facilities to prevent accidental discharge or slug discharges of pollutants shall be provided and maintained at the user's cost and expense. (B) A SPCC plan/slug control plan showing facilities and operating procedures to provide this protection shall be submitted to the Director for review and approval before implementation. The Director shall determine which user is required to develop a plan and require said plan to be submitted within 90 days after notification by the Director. Each user shall implement its SPCC as submitted or as modified after such plan has been reviewed and approved by the Director. Review and approval of such plans and operating procedures by the Director shall not relieve the user from the responsibility to modify and operate its facility as necessary to meet the requirements of this section. Each industrial user required to implement a SPCC plan/slug control plan shall notify the city of any significant changes to the user's operations or systems that might alter the nature, quality, or volume of its wastewater at least 90 days prior to the change. (C) Any user required to develop and implement an accidental discharge/slug control plan shall submit a plan that addresses, at a minimum, the following: (1) Description of discharge practices, including non-routine batch discharges; (2) Description of stored chemicals; (3) Procedures for immediately notifying the POTW of any accidental or slug discharge. Such notification shall also be given for any discharge that would violate any of the standards in Section 52.03(II)—(V); and (4) Procedures to prevent adverse impact from any accidental or slug discharge. Such procedures include, but are not limited to, inspection and maintenance of storage areas, handling and transfer of materials, loading and unloading operations, control of plant site runoff, worker training, building of containment structures or equipment, measures for containing toxic organic pollutants (including solvents), and/or measures and equipment for emergency response. (D) Users shall notify the Director immediately upon the occurrence of a "slug" or "accidental discharge" of substances regulated by this chapter. Users shall notify the Manager of the city's Division of Water Reclamation, or the supervisor on duty at the wastewater treatment facility by telephone immediately upon the occurrence of a slug load or accidental discharge, or bypass of substances prohibited or limited by this chapter. The notification shall include location of discharge, date and time thereof, type of waste, concentration and volume, and corrective actions. Any affected user shall be liable for any expense, loss, or damage to the POTW, in addition to the amount of any assessments or penalties imposed on the city on account thereof under state or federal law. (E) Within five days following an accidental discharge, the user shall submit to the Director a detailed written report describing the cause of the discharge and the measures to be taken by the user to prevent similar future occurrences. The user shall document and maintain sufficient records so as to reflect fairly and accurately any such discharge, including, but not limited to, bypasses of pretreatment facilities. Such notification shall not relieve the user of any expense, loss, damage, or other liability that may be incurred as a result of damage to the POTW, fish kills, or any other damage to person or property; nor shall such notification relieve the user of any assessments, civil penalties, or other liability that may be imposed by this chapter or other applicable law. (F) Signs shall be permanently posted in conspicuous places on the user's premises advising employees whom to call in the event of a slug or accidental discharge. Employers shall instruct all employees who may cause or discover such a discharge with respect to emergency notification procedures. (G) Significant industrial users are required to notify the Director immediately of any changes at its facility affecting the potential for a slug discharge. XIII. Hauled wastewater. (A) Industrial and/or commercial wastes, and by-products and other materials originating from industrial and/or commercial operations outside the city and the city contract service areas shall not be discharged in any form into the wastewater facilities or storm sewer. Written exceptions to this provision may be made by the Director. (B) No person shall access the wastewater facilities for any activity including discharge of hauled septic, industrial, or other wastes except at locations and at times as designated by the Director. Any removal of manhole lids or other access to the wastewater facilities for the purpose of discharging wastes at times and/or locations other than those designated by the Director, or without the expressed permission of the Director, shall be considered a violation and shall be subject to enforcement action including assessments and/or penalties. XIV. Dental dischargers. This section applies to dental dischargers subject to 40 CFR Part 441, the Dental Office Point Source Category (Rule). Dental dischargers are not significant industrial users as defined in 40 CFR Part 403 and are not categorical industrial users or industrial users subject to categorical pretreatment standards as those terms and variations are used in 40 CFR Part 403 and this chapter, as a result of applicability of this rule. Dental dischargers qualifying under 40 CFR Part 441 are for regulatory purposes considered users as the term is used in this chapter. (A) Dental dischargers who place or remove amalgam must install an amalgam separator, implement BMPs, and must certify as such. (B) Dental dischargers who never place amalgam and do not remove amalgam except in limited unplanned, unanticipated circumstances (estimated to be less than five percent of removals) must certify as such, but do not have to install an amalgam separator or implement the BMPs. (C) The following dental dischargers are exempt from this regulation: • Dentists that exclusively practice one or more of the following specialties: oral pathology, oral and maxillofacial radiology, oral and maxillofacial surgery, orthodontics, periodontics, or prosthodontics. • Mobile units providing services in multiple locations. • Dentists that do not discharge any dental wastewater to the sewer, such as when wastewater is sent to a centralized treatment facility.

(Ord. 30739-08, passed 4-23-08; Ord. 32153-25, passed 8-6-25)

Ask a question about Dayton law

Corpus searches the Dayton sections it holds and shows the ones that match, with their citations. Free, no sign-in.