§ 1154.13 — ARCHITECTURE
Codified Ordinances of the City of New Albany, Ohio (Codified through Ordinance No. O-21-2026, enacted July 7, 2026. (Supp. No. 11, Update 1)) · New Albany Codified Ordinances § 1154.13
Corpus is an independent public-information project, not the official City of New Albany website. Stable reference: corpuslaw.us/code/a13fd12b-c814-407c-8b04-3f6c0ff041b3
1154.13 - ARCHITECTURE.
(a) Flagship Projects. Flagship Projects shall not be subject to the requirements of the DGRs, provided that such projects meet the requirements of the New Albany Technology Manufacturing District Landscape and Architecture Standards Plan. (b) Primary Projects. The requirements of this Section 1154.13(b) shall apply only to Primary Projects: (1) General Regulations for all Primary Projects. A. Service and Loading Areas: Service areas and loading docks shall be screened to limit visibility from off-site. B. Building designs shall not mix architectural elements or ornamentation from different styles. C. Buildings shall be required to employ a comparable use of materials on all elevations. D. The number, location, spacing, and shapes of windows and door openings shall be carefully considered. Primary entrances to buildings shall be made sufficiently prominent that they can be easily identified from a distance. E. For office buildings and complexes, achieving a human or pedestrian scale is of less concern. When achieving such a scale is desired, it may be achieved by careful attention to width of facades, size and spacing of window and door openings, and floor to floor heights on exterior walls. F. Use of elements such as shutters, cupolas, dormers, and roof balustrades shall be avoided in building designs that are not based on traditional American architectural styles. Such elements may be employed only when they are common elements of a specific style, and this style shall be replicated in its entirety. When shutters are employed, even if they are non-operable, they must be sized and mounted in a way that gives the appearance of operability. G. Elements such as meter boxes, utility conduits, roof and wall projections such as vent and exhaust pipes, basement window enclosures, and trash containers shall be designed, located, or screened so as to minimize their visibility and visual impact from off-site. Solar energy systems shall be excluded from the requirements of this section to the extent the requirements prevent or limit functionality and/or accessibility to direct sunlight. H. Accessory or ancillary buildings, whether attached or detached, shall be of similar design, materials and construction as the nearest primary structure, if they are visible from a public street right-of-way. Fenestration themes that employ windows, panels and piers that are consistent with the architectural vocabulary of the building are encouraged. Notwithstanding the foregoing, the requirements of this subsection shall not apply to detached accessory structures serving or associated with Advanced Fabric Structures (as defined in Section 1154.14(b)(3)). I. Roof-Mounted Equipment. Complete screening of all roof-mounted equipment shall be required on all four (4) sides of buildings with materials that are consistent and harmonious with the building's façade and character. Such screening shall be provided in order to screen the equipment from off-site view and to buffer sound generated by such equipment. Solar energy systems shall be excluded from the requirements of this section to the extent the requirements prevent or limit functionality and/or accessibility to direct sunlight. J. All building elevations shall be designed to be compatible with each other and to reflect a consistent design approach. K. Gable or hip roofs shall be avoided unless a building design replicates a traditional American architectural style that employs such roof forms. In non-stylistic contemporary designs, low or flat roofs may be employed. Roof visibility shall be minimized. L. Exterior building materials for all buildings other than Advanced Fabric Structures shall be appropriate for contemporary suburban designs and shall avoid overly reflective surfaces. Traditional materials such as, but not limited to, wood, stone, brick, and concrete shall be permitted, along with contemporary materials such as, but not limited to, aluminum, metal, glass, stucco, or cementitious fiberboard (e.g., hardiplank or equivalent) shall be permitted on buildings not employing traditional styles. The use of reflective or mirrored glass shall be prohibited. M. Prefabricated metal buildings, untreated masonry block structures, and buildings featuring poured concrete exterior walls are prohibited. Notwithstanding the foregoing, ancillary structures built and operated for the purpose of enclosing equipment and which are not occupied by a tenants or persons on a regular basis may be constructed using pre-engineered metal. N. Generally, the quantity of materials selected for a building shall be minimized. A single material selection for the independent building components of roof, wall and accents is permitted (i.e., Architectural Grade shingle roof with Brick Masonry wall and EIFS Cornice and Accents). O. Loading docks are not required to have the same degree of finish as a main entry unless they are visible from a public right-of-way. P. Buildings and structure shall be designed to be harmonious in character to other buildings and structures within the same Flagship project or Primary Project, as appliable. Façade colors shall be coordinated to complement each other. (2) Additional Standards for Non-Office Buildings within Primary Projects: Buildings that are constructed to accommodate certain uses are not governed by the City's Design Guidelines and Requirements (DGRs). For example, buildings that are constructed for the operation of data centers, manufacturing, warehousing and/or distribution uses are not subject to the DGRs and can present challenges in meeting the community standard for architectural design. Such buildings are necessarily large and typically include long walls that together form a square or rectangular box. The goal for the development of buildings that are not subject to the DGRs is to balance the practical needs of these buildings with the desire to provide exterior designs that are attractive and complimentary to the architecture that will be found elsewhere in the TMD. Architecture by its nature is a subjective medium, meaning that the adoption of strict objective standards in all instances may not provide the best means for achieving appropriate design. In recognition of this fact, the standards set forth herein provide guidelines and suggestions for designing buildings that are not subject to the DGRs in an effort to set expectations for the quality of architecture that will be expected for these structures. On the other hand, these standards are meant to allow for some flexibility to encourage innovative design provided that the spirit and intent of these provisions are met. In designing such buildings (other than Advanced Fabric Structures), the user or applicant shall take into account the following, which are intended to set a level of expectation for the quality of design: A. Architectural design for all portions of a building or structure that are visible from a public right-of-way (excluding public rights-of-way whose primary purpose is to accommodate truck traffic or service loading areas) shall meet the community standard in terms of quality while taking into account the unique nature of the use(s) that will be found therein. B. Uninterrupted blank wall facades shall be prohibited to the extent that they are visible from a public right-of-way. Design variations on long exterior walls shall be employed in order to create visual interest. Examples of such design variations include, but are not limited to, the use of offsets, recesses and/or projections, banding, windows, and/or reveals; scoring of building facades; color changes; texture or material changes; and variety in building height. C. The use of one (1) or more architectural or design elements may be used to soften the aesthetics of the building, such as, but not limited to, canopies, porticos, overhangs, arches, outdoor patios, community spaces, or similar devices. D. Contemporary exterior designs, while not required, shall be encouraged in order to create architecture that does not look aged or dated even many years after the facility is built. E. Landscaping and/or the use of existing vegetation shall be utilized where appropriate to enhance the aesthetics of the building and to lessen its visual impact when viewed from public rights-of-way. F. Utility yards, essential service areas, bulk storage areas and similar may be paved or gravel. HVAC, generators and similar equipment and associated gravel or concrete yards or pads shall be located subject to the minimum building setbacks. (3) Regulations for Advanced Fabric Structures: A Primary Project with a development proposal on a single parcel or multiple contiguous parcels containing at least one hundred (100) acres shall be permitted to include Advanced Fabric Structures as primary or accessory buildings. "Advanced Fabric Structures" shall be defined to mean "a clear-span building with a durable, tensioned fabric used as the primary exterior finish material for its roof, all or some its exterior facades, or both." Advanced Fabric Structures shall be permitted only within a Primary Project. Advanced Fabric Structures, when installed, shall: A. Utilize tensioned fabric that is certified by its manufacturer as having a useful life of at least twenty (20) years and being able to withstand wind speeds of at least one hundred (100) miles per hour. B. Have a building substructure that consists of aluminum, steel, or some other metallic materials to ensure durability and longevity for the building. C. Have a climate-controlled interior. D. Not exceed sixty-five (65) feet in height at the highest point of the roof. E. Not be required to include windows if the lack of windows is needed for security reasons and/or for temperature control. F. Have a minimum building setback of one hundred (100) feet from all perimeter boundary lines of the parcel on which it is located and of two hundred (200) feet from any public street right-of-way.
(Ord. O-46-2021. Passed 12-14-21; Ord. O-17-2025. Passed 5-6-25.)
Ask a question about New Albany law
Corpus searches the New Albany sections it holds and shows the ones that match, with their citations. Free, no sign-in.
