16.06.550 - Footings.

IRC Section R403.1 is hereby amended to read as follows: R403.1 General. All exterior walls shall be supported on continuous solid or fully grouted masonry or concrete footings, crushed stone footings, wood foundations, or other approved structural systems that shall be of sufficient design to accommodate all loads according to Section R301 and to transmit the resulting loads to the soil within the limitations as determined from the character of the soil. Footings shall be supported on undisturbed natural soils or engineered fill. Concrete footings shall be designed and constructed in accordance with the provisions of Section R403 or in accordance with ACI 332. All portions of the foundation, including the stem wall to the base of the foundation, must be connected by the use of reinforcing steel. The minimum connections must be at all openings and corners by the use of no smaller than a #3 reinforcing bar.

(Ord. 3364, § 2, December 10, 2012; Ord. No. 3961, § 28, July 10, 2023).