§ 16.16.100 — Exceptions to the NEC
Code of Ordinances of the City of Edmond, Oklahoma (Codified through Ordinance No. 4097, enacted August 10, 2026 (Supp. No. 40)) · Edmond Code of Ordinances tit. 16, § 16.16.100
Corpus is an independent public-information project, not the official City of Edmond website. Stable reference: corpuslaw.us/code/a9b88928-7ad2-42bd-b1e1-d3e1e7813d19
16.16.100 - Exceptions to the NEC.
The NEC is hereby modified by adding the following language: All installations hereafter installed within the corporate limits of the City of Edmond shall be done in accordance with the NEC with the following deviations there from: 1. No conductors smaller than No. 12 shall be permitted on 120 volt, 15 and 20 Amp circuits. 2. All wiring hereinafter installed in the City of Edmond shall be installed in metal or plastic raceways with the following exceptions: a. All N.M.C. (Romex) installed in dwellings shall be grounding type as approved by the NEC. b. When less than 25 percent of a one-family residence is converted to a commercial occupancy; then, and in that event only, that portion of the building in which the occupancy has changed, shall be rewired in metal raceway to comply with the standards of this ordinance. When such a conversion exceeds 25 percent, the entire structure shall be rewired in metal raceway to comply with the standards of this ordinance; unless the electrical inspector determines that the existing wiring meets the current NEC residential requirements and this would be the more stringent of the two. c. All new circuit wiring installations shall have an equipment grounding conductor in the form of a wire either solid or stranded; insulated, covered, or bare. Circuit conductor enclosures, whether rigid metal conduit, intermediate metal conduit, electrical metallic tubing, flexible metal conduit, or other metallic enclosures shall not be accepted as an equipment grounding conductor. 3. Conductors less than No. 12 copper AWG will be permitted for special circuits, such as controls, public address systems, annunciators and signal wiring. 4. Heaters: All bathroom element type heaters must be wired on a separate circuit from all other wiring and provided with proper overcurrent protection. 5. Service Entrance: a. In the event a mast-type riser is required to attain the required height for service drop conductors above finish grade, it shall be of rigid galvanized conduit, minimum size of one and one-half inches (1-1/2) and shall be continuous from weatherhead to meter base. Electrical metal tubing shall be allowed only in approved locations per the current NEC requirements. b. Space shall be provided to accommodate meters and associated equipment at the point of delivery as designated by the electric utility department. The location shall be readily accessible. c. The capacity and type of meter installation shall be determined by the electric utility department to accommodate the load and type of service supplied. d. The electric meter must be installed in a cabinet or socket provided by the electric utility department. Meters shall not be installed inside of buildings without special permission from the electric utility department. e. No electrical equipment, such as electrical conduit, meters, etc., shall be installed on an electric utility department pole without special permission from the electric utility department. f. The electrical contractor shall furnish approved cabinets for instrument transformers. The electrical contractor shall install this equipment, including a raceway from instrument transformers, to meters. g. At the service point, all clearance requirements shall be increased as required by the electric utility department to ensure service drop (overhead) and service lateral (underground) conductors meet IEEE C2 (National Electric Safety Code) requirements. 6. All electrical conductors installed within the corporate limits of the City of Edmond after January 1, 1980 must be copper conductors except that aluminum and copper-clad aluminum conductors may be used for direct earth burial or exposed in free air not inside of buildings. Such aluminum and copper-clad aluminum must be terminated outside of the outside walls of buildings. a. Exceptions: Aluminum wire shall only be allowed inside commercial buildings and under the following restrictions and limitations: b. Aluminum wire shall be approved by the building official prior to the installation to verify it meets or exceeds the requirements of copper conductors of equal amperage applications. c. Aluminum wire shall be limited to not less than size 2/0. d. Aluminum wire size 2/0 and larger shall only be allowed to penetrate inside the building up to the first point of connection to the main distribution electrical equipment for the purpose of supplying power to the building. Aluminum wire cannot be used for any other purposes. 7. Meter bases installed for sprinkler systems and similar equipment for the entrances to housing additions and similar areas shall be permitted to be installed no lower than 24 inches from the bottom of the meter base to the ground. 8. Meter bases installed on temporary poles shall be mounted 4'-0" minimum from the bottom of the meter base to the ground. 9. Electric and gas shall not be installed in the same underground trench. Exceptions: a. For customer owned facilities, past the service point, where it is technically infeasible to separate the gas and electric, burial in the same trench will be allowed under all of the following conditions: i. Provide identification tape specifying gas in same trench and located above the electrical conductors. ii. Provide minimum 2 inches of concrete separation between gas and electric located in the same trench with a minimum six inches of vertical and horizontal clearance between gas and electric. iii. Electric must also be located a minimum of 24 inches below final grade and gas a minimum 18 inches below final grade or to minimum code and or electric utility department requirements, whichever is more stringent. b. For installations, under the exclusive control of the electric utility department, prior to the service point, as defined in the NEC, shall be subject to the requirements of IEEE C2 (National Electric Safety Code). 10. Article 210.8(A)(1) is hereby modified to read: (1) Bathrooms, for GFCI in all bathrooms located in Dwelling Units constructed in accordance with the IRC, the GFCI protection shall be located in each individual bathroom, unless an approved GFCI breaker it utilized.
(Ord. 3364, § 2, December 10, 2012; Ord. 3575, § 19, December 12, 2016; Ord. No. 3961, § 63, July 10, 2023).
Ask a question about Edmond law
Corpus searches the Edmond sections it holds and shows the ones that match, with their citations. Free, no sign-in.