For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 12.50.710 — Design Standards for All Residential Development

Municipal Code of the City of Hillsboro, Oregon (Codified through Ordinance No. 6513, adopted March 3, 2026 (Supp. No. 2)) · Hillsboro Community Development Code subch. 12.50, § 12.50.710

Corpus is an independent public-information project, not the official City of Hillsboro website. Stable reference: corpuslaw.us/code/1fb9ee34-f435-44d9-bfa9-7cc56591e98d

12.50.710 - Design Standards for All Residential Development.

A. Purpose. These design standards are intended to generally assure that new residential development will be compatible with the City's character, while allowing for some flexibility for new development. In addition, the regulations provide certainty to property owners, developers and neighbors regarding allowable design. B. Applicability. Except where noted in each subsection, these standards shall apply as follows: 1. These standards apply to all residential housing types. In addition, Section 12.50.715 applies only to middle housing and Section 12.50.720 applies only to multiple dwelling residential. 2. When criteria a. and b. below are met, Subsections 12.50.710.C.3. (Foundation Materials), C.4 (Articulation) and C.5 (Detailed Design Elements) do not apply: a. The lot was created before July 1, 2022 and is less than 0.25 acres in size; and b. The lot is not within a designated plan district. 3. These standards and the standards of Section 12.50.715 do not apply to middle housing created through conversion of, or addition to, an existing dwelling; however, the conversion or addition shall not increase nonconformance with these standards. 4. The standards do not apply to accessory structures, detached garages, or carports. 5. Applicants may request adjustments to these standards and the additional standards in Sections 12.50.715 and 12.50.720 pursuant to Sections 12.80.154 and 12.80.156. C. Standards. 1. Main Entries. a. For Housing Types With Shared Entries. In addition to the main entry standards for middle housing and multiple dwelling structures, common main entries shall meet the following standards: i. Common main entries for housing types with shared entries shall face the front property line, unless one of the following circumstances applies: (A) Buildings on corner lots may have the main entry facing either street or the intersection of the streets. (B) Buildings with more than one main entry may have only one entry facing the front property line. (C) Building entries that face a landscaped shared courtyard are exempt from this requirement. b. For Housing Types With Individual Entries. At least one main entrance to a dwelling unit shall meet both subparagraphs i. and ii., below. These requirements do not apply to entries for ADUs. i. The entry shall be no further than 8 feet behind the longest street-facing wall of the building, as illustrated in Figure 12.50.710-A; and ii. The entry shall either, face the street, be at an angle of no more than 45 degrees from the street, or open to a porch. If the entry opens to a porch, the porch shall meet all of the following standards: (A) Have a minimum area of 25 square feet, with a minimum depth of 5 feet; (B) Have at least one porch entry facing the street; and (C) Have a roof that is a maximum of 12 feet above the floor of the porch as measured to the lowest element of the roof; and that covers at least 30% of the porch area. Figure 12.50.710-A: Main Entrances [image omitted; see the official code] 2. Windows. At least 15% of the area of each façade facing a street or commonly-accessible open space, and 20% of the ground floor facing those 2 features, shall be glazing or entry doors with glazing insets, as illustrated in Figure 12.50.710-B. a. Transparent windows allowing views from the dwelling to the street or public open space meet this standard. Up to 25% of the required area may also be met by privacy (translucent) windows, glass blocks, or entry doors with translucent glass. b. Window area is considered the entire area within the outer window frame, including any interior window grid. c. All of the window area of the street-facing wall(s) of an attached garage, and half of the total window area in the door(s) of an attached garage may be counted toward this standard. d. Doors used to meet this standard contain glass and shall face the street or be at an angle of not more than 45 degrees from the street. Security viewing devices ("peepholes") do not by themselves meet this standard. e. Door area is considered the portion of the door that moves. Door frames do not count toward this standard. Figure 12.50.710-B: Windows and Entry Doors [image omitted; see the official code] 3. Foundation Materials. Concrete or concrete block may be used as foundation material only if the concrete or concrete block is not exposed above finished grade by more than 3 feet. On sites with slopes greater than 20%, the use of concrete or concrete block as a foundation material may be increased to 6 feet. 4. Articulation. All residential dwelling structures shall incorporate elements that break up all façades facing streets or commonly-accessible open spaces into smaller planes using 4 or more of the elements listed below, as illustrated in Figure 12.50.710-C. On corner or multi-frontage lots, 4 or more elements shall be provided on each street- or open space-facing façade. Architectural features that meet the standards in this section include the following features: a. A covered porch with a minimum depth of 5 feet (measured horizontally from the face of the main façade) and a minimum length of 6 feet; b. A balcony at least 4 feet deep and 8 feet wide, that is accessible from one interior room; c. A bay window at least 6 feet wide, bumped out by at least 2 feet; d. A recessed building entry at least 2 feet deep, as measured horizontally from the face of the main building façade, and at least 5 feet wide; e. A section of the façade, at least 6 feet in width, that is either recessed or bumped out by at least 2 feet deep from the front wall plane; f. An offset on the building face of at least 16 inches from one exterior wall to the other; g. A gabled dormer at least 4 feet wide and integrated into the roof form; h. Roof line offset of at least 2 feet from the top surface of one roof to the top surface of the other; or i. Other similar architectural features proposed by the applicant if approved by the Review Authority as part of a Type II review. Figure 12.50.710-C: Articulation Examples [image omitted; see the official code] 5. Detailed Design Elements. All residential dwelling structures shall provide at least 9 of the following elements, as illustrated in Figure 12.50.710-D, on any façade facing a street or commonly-accessible open space. On all other façades, at least 4 of the following elements shall be provided: a. A recessed building entry at least 2 feet deep, as measured horizontally from the face of the main building façade, and at least 5 feet wide; b. Roof eaves on all elevations that project at least 12 inches from the intersection of the roof and the exterior walls; c. A minimum of 3 gable end brackets (either triangular knee braces or rake brackets), spaced a maximum of 15 feet on center; d. Roof line offset of at least 2 feet from the top surface of one roof to the top surface of the other; e. Hip or gambrel roof design with a minimum pitch of 6/12; f. Siding in gables which differs from the primary siding type (e.g., shingle siding in gable when primary siding is horizontal lap); g. Tile roofs; h. Fiber-cement horizontal lap siding between 3 and 7 inches wide (the visible portion once installed); i. Exterior finish materials covering at least 40% of the street-facing façade from one or more of the following: brick, fiber-cement shingles, stone, or stucco (this option is not available to be counted towards the minimum number of elements for façades that do not face a street); j. Window trim around all windows with a minimum width of 3 inches and a minimum thickness of ⅝ inches; k. On any façade not facing a street or commonly-accessible open space, minimum 15% of the area in glazing or entry doors, consistent with subparagraphs C.2.a through e; l. Recesses in all windows on a façade facing a street of at least 3 inches as measured horizontally from the face of the façade (this option is not available to be counted towards the minimum number of elements for façades that do not face a street); m. Mullions or window grids in all windows on a façade; n. Attached garage width, as measured on the inside of the garage door frame, of 35% or less of the width of the street-facing façade; o. Horizontal band or barge boards; p. Color palette including 4 colors. Colors may be paint or intrinsic to the material (e.g., wood, brick, or stone). One main color shall cover at least 40% of the street-facing façade and each of the other colors shall be used on a minimum of 4 square feet; and/or q. Other similar architectural features proposed by the applicant if approved by the Review Authority as part of a Type II review. Figure 12.50.710-D: Detailed Design Elements Examples [image omitted; see the official code]

(Ord. 6451 § 1, 2023; Ord. 6401 § 1, 2022; Ord. 6322 § 1, 2019; Ord. 6294 § 1, 2019; Ord. 6178 § 1, 2016)

Ask a question about Hillsboro law

Corpus searches the Hillsboro sections it holds and shows the ones that match, with their citations. Free, no sign-in.