§ 12.50.715 — Additional Design Standards for Middle Housing
Municipal Code of the City of Hillsboro, Oregon (Codified through Ordinance No. 6513, adopted March 3, 2026 (Supp. No. 2)) · Hillsboro Community Development Code subch. 12.50, § 12.50.715
Corpus is an independent public-information project, not the official City of Hillsboro website. Stable reference: corpuslaw.us/code/3371b899-973b-4cc2-bb29-64963adf0fb8
12.50.715 - Additional Design Standards for Middle Housing.
A. Purpose. These design standards are intended to generally assure that new middle housing development will be compatible with the City's character, while allowing for some flexibility for new development. In addition, the regulations provide certainty to property owners, developers and neighbors regarding allowable design. B. Applicability. Except as specified below, these standards shall apply to all new triplexes, quadplexes, 3 or more unit townhouses, and cottage cluster projects (including accessory structures) in all zones. C. Standards for Triplexes and Quadplexes. 1. Garages and Off-Street Parking Areas. The combined width of all garages and outdoor on-site parking and maneuvering areas shall not exceed a total of 50% of any street frontage (other than an alley), as illustrated in Figure 12.50.715-A. Figure 12.50.715-A: Triplex and Quadplex: Width of Garages and Parking Areas [image omitted; see the official code] 2. Driveway Approach. Driveway approaches must comply with all of the following: a. The total width of all driveway approaches must not exceed 32 feet per frontage, as measured at the property line, as illustrated in Figure 12.50.715-B. For lots or parcels with more than 1 frontage, see subparagraph c. b. Driveway approaches may be separated when located on a local street and when spaced according to the requirements of the Hillsboro Design and Construction Standards. c. In addition, lots or parcels with more than 1 frontage must comply with the following: i. Lots or parcels must access the street with the lowest functional classification for vehicle traffic. For lots or parcels abutting an alley that is improved according to the Hillsboro Design and Construction Standards, access must be taken from the alley, as illustrated in Figure 12.50.715-C. ii. Lots or parcels with frontages only on collectors and/or arterial streets shall meet the access spacing standards in the Hillsboro Design and Construction Standards. iii. Lots or parcels with frontages only on local streets may have either: • Two driveway approaches not exceeding 32 feet in total width on 1 frontage; or • One maximum 16-foot-wide driveway approach per frontage, as illustrated in Figure 12.50.715-D. Figure 12.50.715-B: Triplex and Quadplex: Driveway Approach Width and Separation on Local Street [image omitted; see the official code] Figure 12.50.715-C: Triplex and Quadplex: Alley Access [image omitted; see the official code] Figure 12.50.715-D: Triplex and Quadplex: Driveway Approach Options for Multiple Local Street Frontages [image omitted; see the official code] D. Standards for Three or More Unit Townhouses. 1. Maximum Number of Attached Dwelling Units. The maximum number of townhouse units that may be attached together to form a group is specified below. a. R-10, R-8.5, R-7, R-6, R-4.5, SCR-OTC, and SCR-DNC zones: Maximum of 4 attached units per group. b. MR-1, SCR-LD, SCR-MD, MU-N: Maximum of 8 attached units per group. c. All other zones where townhouses are permitted: No limit. 2. Driveway Access and Parking. Townhouses with frontage on a public street shall meet the following standards: a. Alley Access. Townhouse project sites abutting an alley that is improved according to the Hillsboro Design and Construction Standards shall take vehicular access from the alley. b. Front Access. Garages on the front façade of a townhouse, off-street parking areas in the front yard, and driveways in front of a townhouse are allowed if they meet the following standards: i. A maximum of one driveway is allowed for every 2 townhouse units, except that where there is an odd number of townhouse units in a grouping, one driveway may provide access to a single dwelling unit. ii. The minimum width for a driveway is 15 feet, except that the minimum width for a single unshared driveway is 10 feet. iii. The maximum width for a driveway is 18 feet, except that the maximum width for a single unshared driveway is 12 feet. iv. Driveways must be located a minimum of 22 feet apart to minimize vehicle conflicts with pedestrians and to preserve on-street parking. Distance between driveways is measured along the front property line. c. The following standards apply to driveways and parking areas for townhouse projects that do not meet all of the standards in subparagraph a. or b. i. Off-street parking areas shall be located in the rear yard. No off-street parking shall be allowed in the front yard or side yard of a townhouse. ii. A townhouse project that includes a corner lot shall take access from a single driveway approach on the side of the corner lot, as illustrated in Figure 12.50.715-E. Figure 12.50.715-E: Townhouses on Corner Lot with Shared Access [image omitted; see the official code] iii. Townhouse projects that do not include a corner lot shall consolidate access for all lots into a single driveway, as illustrated in Figure 12.50.715-F. The driveway and approach are not allowed in the area directly between the front façade and front lot line of any of the townhouses. Figure 12.50.715-F: Townhouses with Consolidated Access [image omitted; see the official code] iv. A townhouse project that includes consolidated access or shared driveways shall grant access easements to allow normal vehicular access and emergency access. 3. Main Entries. In addition to the standards in Section 12.50.710.C.1, main entries for townhouses shall meet the following standards: a. In light rail or mixed-use zones, townhouses fronting on a major pedestrian route shall have separate entries directly to the route. b. A covered balcony may be substituted for a front porch and shall be approved as a substitute if all of the following standards are met: i. The balcony shall be on the same façade as the main entry; ii. The balcony shall be accessible from the interior of the house; iii. The area covered by the balcony shall be at least 48 square feet in area and at least 8 feet wide; and iv. The floor of the balcony is no more than 15 feet above finished grade. E. Standards for Cottage Clusters. 1. Courtyard Required. All cottages within a single cottage cluster must share a common courtyard. A cottage cluster project may include more than 1 cluster and more than 1 common courtyard. 2. Number of Dwellings. a. A single cottage cluster shall contain a minimum of 3 and a maximum of 8 cottages. b. A lot shall contain no more than 1 cottage cluster. c. Existing residential units shall be counted towards the minimum and maximum cottages allowed. 3. Building Separation and Setbacks. a. Cottages shall be separated by a minimum distance of 6 feet. The minimum distance between all other structures, including accessory structures, shall be in accordance with building code requirements. b. All other setbacks are provided in the applicable base zone or plan district. 4. Building Height. The maximum building height for all structures is 25 feet. 5. Footprint. The building footprint for each cottage shall be less than 900 square feet. Attached garages up to 200 square feet shall be exempted from the calculation of maximum building footprint. 6. Floor Area. a. Notwithstanding the definition of "floor area" in Section 12.01.500, for the purpose of this section, "floor area" includes the area devoted to private garages. b. Floor Area. The maximum permitted floor area of each cottage is 1,550 square feet. c. Average Floor Area. The average floor area permitted for a cottage cluster shall not exceed 1,000 square feet per cottage. Community buildings shall be included in the average floor area calculation for a cottage cluster. 7. Cottage Orientation. Cottages must be clustered around a common courtyard and must meet the following standards, as illustrated in Figure 12.50.715-H: a. Each cottage within a cluster must either abut the common courtyard or must be directly connected to it by a pedestrian path. b. A minimum of 50% of cottages within a cluster must be oriented to the common courtyard and must: i. Have a main entrance facing the common courtyard; ii. Be within 10 feet from the common courtyard, measured from the façade of the cottage to the nearest edge of the common courtyard; and iii. Be connected to the common courtyard by a pedestrian path. c. Cottages within 20 feet of a street property line may have their entrances facing the street. d. Cottages not facing the common courtyard or the street must have their main entrances facing a pedestrian path that is connected to the common courtyard. 8. Common Courtyard Design Standards. Common courtyards must meet the following standards, as illustrated in Figure 12.50.715-G: a. The common courtyard must be a single, contiguous piece. b. Cottages must abut the common courtyard on at least 2 sides of the courtyard. c. The common courtyard must contain a minimum of 150 square feet per cottage within the associated cluster. d. The common courtyard must be a minimum of 15 feet wide at its narrowest dimension. e. The common courtyard shall be developed with a mix of landscaping, lawn area, pedestrian paths, and/or paved courtyard area, and may also include recreational amenities. Impervious elements of the common courtyard shall not exceed 75% of the total common courtyard area. f. Pedestrian paths must be included in a common courtyard. Paths that abut a courtyard shall count toward the courtyard's minimum dimension and area. Parking areas and driveways do not qualify as part of a common courtyard. Figure 12.50.715-G: Cottage Cluster Orientation and Common Courtyard Standards [image omitted; see the official code] 9. Community Buildings. Cottage cluster projects may include community buildings for the shared use of residents that provide space for accessory uses such as community meeting rooms, guest housing, exercise rooms, day care, or community eating areas. Community buildings must meet the following standards: a. Each cottage cluster is permitted 1 community building. b. The community building shall have a maximum floor area of 1,400 sf. In addition, the community building shall count towards the maximum average floor area of the cottage cluster, pursuant to Subparagraph 12.50.715.E.6.c. c. Community buildings shall not be used for long-term residential occupancy. For the purposes of this standard, long-term residential occupancy shall mean the continued use by the same occupant for longer than 14 days in any 60-day timeframe or for more than 30 days in a calendar year. 10. Pedestrian Access. a. An accessible pedestrian path must be provided that connects the main entrance of each cottage to the following: i. The common courtyard; ii. Shared parking areas; iii. Community buildings; and iv. Sidewalks in public rights-of-way abutting the site or rights-of-way if there are no sidewalks. b. The pedestrian path shall meet the standards in Subsection 12.50.420.D.5. 11. Windows. All street-facing façades of cottages within 20 feet of a street property line must meet the window coverage standards of Subsection 12.50.710.C.2. 12. Articulation and Detailed Design Elements. When a cottage cluster project exceeds the threshold in Subsection 12.50.710.B.2, the following standards apply: a. If any part of a cottage is within 20 feet of a street property line, its street-facing façade must include: i. Three of the articulation elements in Subsection 12.50.710.C.4; and ii. Five of the detailed design elements in Subsection 12.50.710.C.5. b. The façade of each cottage facing the common courtyard must include: i. Two of the articulation elements in Subsection 12.50.710.C.4; and ii. Three of the detailed design elements in Subsection 12.50.710.C.5. 13. Parking Design. (Illustrated in Figure 12.50.715-H.) a. Clustered Parking. Off-street parking may be arranged in clusters, subject to the following standards: i. A parking cluster must not exceed 8 contiguous spaces. ii. Parking clusters must be separated from other spaces by at least 4 feet of landscaping. iii. Clustered parking areas may be covered. iv. Parking clusters must also meet the standards in Section 12.50.360, except where they conflict with these standards. b. Parking Location and Access. i. Off-street parking areas with 5 or more spaces shall not be located within 20 feet from any property line that abuts a street as defined in Section 12.01.500. ii. No off-street parking space or vehicle maneuvering area is permitted between a property line that abuts a street and the front façade of cottages located closest to that property line. iii. No off-street parking space is permitted within 10 feet of any other property line external to the cottage cluster, except property lines abutting an alley. Driveways and drive aisles are permitted within 10 feet of other external property lines. c. Screening. Landscaping, fencing, or walls at least 3 feet tall shall separate clustered parking areas and parking structures from common courtyards and public streets. d. Garages and Carports. i. Garages and carports (whether shared or individual) must not abut common courtyards. ii. Detached garages must not exceed 400 square feet in floor area. iii. Garage doors shall not exceed 20 feet in width. 14. Accessory Buildings. Accessory buildings shall not exceed 400 square feet in floor area. 15. Existing Structures. On a lot or parcel to be used for a cottage cluster project, an existing, single detached dwelling on the same lot at the time of proposed development of the cottage cluster may remain within the cottage cluster project area under the following conditions: a. The existing dwelling may be non-conforming with respect to the requirements of this Subsection 12.50.715.E. b. The existing dwelling may be expanded up to a maximum height of 25 feet or a maximum building footprint of 900 square feet; however, existing dwellings that exceed these maximum height and/or footprint standards may not be expanded. c. The floor area of the existing dwelling shall not count towards the maximum average floor area of a cottage cluster, per Subparagraph 12.50.715.E.6.c. d. The existing dwelling shall be excluded from the common courtyard orientation standards, per Subparagraph 12.50.715.E.7.b. Figure 12.50.715-H: Cottage Cluster Parking Design Standards [image omitted; see the official code]
(Ord. 6451 § 1, 2023; Ord. 6401 § 1, 2022)
Ask a question about Hillsboro law
Corpus searches the Hillsboro sections it holds and shows the ones that match, with their citations. Free, no sign-in.
