Sec. 21-171. - General standards.

In all areas of special flood hazard, the following provisions are required: (1) Reasonably safe from flooding. All permit applications shall be reviewed to determine whether proposed building sites will be reasonably safe from flooding. (2) New construction and substantial improvements shall be anchored to prevent flotation, collapse or lateral movement of the structure. (3) Manufactured homes shall be anchored to prevent flotation, collapse or lateral movement. Methods of anchoring may include but are not limited to use of over-the-top or frame ties to ground anchors. This standard shall be in addition to and consistent with applicable state requirements for resisting wind forces. (4) New construction and substantial improvements shall be constructed with materials and utility equipment resistant to flood damage. (5) New construction and substantial improvements shall be constructed by methods and practices that minimize flood damage. (6) Critical development shall be elevated to the 500-year flood elevation or be elevated to the highest known historical flood elevation (where records are available), whichever is greater. If no data exists establishing the 500-year flood elevation or the highest known historical flood elevation, the applicant shall provide a hydrologic and hydraulic engineering analysis that generates 500-year flood elevation data, (7) Electrical, heating, ventilation, plumbing, air conditioning equipment and other service facilities shall be designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding. (8) New and replacement water supply systems shall be designed to minimize or eliminate infiltration of floodwaters into the systems. (9) New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of floodwaters into the systems and discharges from the systems into floodwaters. (10) Site waste disposal systems shall be located and constructed to avoid impairment to them or contamination from them during flooding. (11) Gas or liquid storage tanks. All gas or liquid storage tanks, either located above ground or buried, shall be anchored to prevent floatation and lateral movement resulting from hydrodynamic and hydrostatic loads. (12) Any alteration, repair, reconstruction or improvements to a structure which is in compliance with the provisions of this article shall meet the requirements of new construction as contained in this article. (13) Non-conforming buildings or uses. Non-conforming buildings or uses may not be enlarged, replaced, or rebuilt unless such enlargement or reconstruction is accomplished in conformance with the provisions of this article. Provided, however, nothing in this article shall prevent the repair, reconstruction, or replacement of an existing building or structure located totally or partially within the floodway, provided that the bulk of the building or structure below base flood elevation in the floodway is not increased and provided that such repair, reconstruction, or replacement meets all of the other requirements of this article. (14) American with Disabilities Act (ADA). A building must meet the specific standards for floodplain construction outlined in this ordinance, as well as any applicable ADA requirements. The ADA is not justification for issuing a variance or otherwise waiving these requirements. Also, the cost of improvements required to meet the ADA provisions shall be included in the costs of the improvements for calculating substantial improvement.

(Code 1979, § 6-12051; Ord. No. 2017-090, 12-5-17)

Ask a question about Columbia law

Corpus searches the Columbia sections it holds and shows the ones that match, with their citations. Free, no sign-in.