§ 21-172 — Specific standards
Code of Ordinances, City of Columbia, South Carolina (Supp. No. 35: codified through Ordinance No. 2025-090, enacted October 28, 2025) · Columbia, S.C., City Code § 21-172
Corpus is an independent public-information project, not the official City of Columbia website. Stable reference: corpuslaw.us/code/fd2147e5-aedf-4ff1-a815-c724a24fa222
Sec. 21-172. - Specific standards.
In all areas of special flooding hazard where base flood elevation data has been provided, the following provisions are required: (1) Residential construction. New construction and substantial improvement of any residential structure (including manufactured homes) shall have the lowest floor, including machinery and equipment, elevated no lower than two feet above the base flood elevation. No basements are permitted. Should solid foundation perimeter walls be used to elevate a structure, flood openings sufficient to facilitate the unimpeded movement of floodwaters shall be provided in accordance with standards of subsection (3) of this section. (2) Nonresidential construction. New construction and substantial improvement of any commercial, industrial or nonresidential structure (including manufactured homes) shall have the lowest floor, including machinery and equipment, elevated no lower than two feet above the level of the base flood elevation. No basements are permitted. Structures located in all A zones may be flood proofed in lieu of being elevated provided that all areas of the structure below the required elevation are watertight with walls substantially impermeable to the passage of water, and use structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effects of buoyancy. A registered professional engineer or architect shall certify that the standards of this subsection are satisfied. (3) Elevated buildings. New construction and substantial improvements of elevated buildings that include fully enclosed areas formed by foundation and other exterior walls below the base flood elevation shall be designed to preclude finished living space and designed to allow for the entry and exit of floodwaters to automatically equalize hydrostatic flood forces on exterior walls. a. Designs for complying with this requirement must either be certified by a professional engineer or architect or meet the following minimum criteria: 1. A minimum of two openings on different walls shall be provided having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding; 2. The bottom of all openings shall be no higher than one foot above the higher of the interior or exterior grade immediately under the opening; 3. Only the portions of openings that are below the base flood elevation can be counted towards the required net open area; 4. Openings may be equipped with screens, louvers, valves or other coverings or devices provided they permit the automatic flow of floodwaters in both directions; 5. Fill placed around foundation walls must be graded so that the grade inside the enclosed area is equal to or higher than the adjacent grade outside the building on at least one side of the building; and 6. Hazardous velocities. Hydrodynamic pressure must be considered in the design of any foundation system where velocity waters or the potential for debris flow exists. If flood velocities are excessive (greater than 5 feet per second), foundation systems other than solid foundations walls should be considered so that obstructions to damaging flood flows are minimized. (4) Enclosures below lowest floor: a. Electrical, plumbing and other utility connections are prohibited below the base flood elevation. b. Access to the enclosed area shall be the minimum necessary to allow for parking of vehicles (garage door) or limited storage of maintenance equipment used in connection with the premises (standard exterior door) or entry to the living area (stairway or elevator). c. The interior portion of such enclosed area shall not be partitioned or finished into separate rooms. d. All construction materials below the required lowest floor elevation specified in the specific standards should be of flood resistant materials. (5) Standards for manufactured homes and recreational vehicles. a. All manufactured homes placed or substantially improved on individual lots or parcels, in expansions to existing manufactured home parks or subdivisions, or in substantially improved manufactured home parks or subdivisions must meet all the requirements for new construction, including elevation and anchoring. b. All manufactured homes placed or substantially improved in an existing manufactured home park or subdivision must be elevated so that: 1. The lowest floor of the manufactured home is elevated no lower than two feet above the level of the base flood elevation. 2. The manufactured home chassis is supported by reinforced piers, or other foundation elements of at least an equivalent strength, of no less than 36 inches in height above grade. 3. The manufactured home must be securely anchored to the adequately anchored foundation system to resist flotation, collapse and lateral movement. 4. In an existing manufactured home park or subdivision on which a manufactured home has incurred substantial damage as the result of a flood, any manufactured home placed or substantially improved must meet the standards of this section. 5. An evacuation plan must be developed for evacuation of all residents of all new, substantially improved or substantially damaged manufactured home parks or subdivisions located within flood-prone areas. This plan shall be filed with and approved by the local floodplain administrator and the local emergency preparedness coordinator. c. All recreational vehicles placed on sites must either: 1. Be on site for fewer than 180 consecutive days; 2. Be fully licensed and ready for highway use; or 3. Meet all the requirements for new construction, including anchoring and elevation requirements of this section. d. A recreational vehicle is ready for highway use if it is on its wheels or jacking system, is attached to the site only by quick-disconnect type utilities and security devices, and has no permanently attached structures. (6) Floodways. Located within areas of special flood hazard are areas designated as floodways. Since the floodway is an extremely hazardous area due to the velocity of floodwater, which carries debris and potential projectiles and has erosion potential, the following provisions shall apply: a. Encroachments are prohibited, including fill, new construction, substantial improvements and other development, unless certification (with supporting technical data) by a professional engineer is provided demonstrating that encroachment will not result in any increase in flood levels during the base flood discharge. b. A conditional letter of map revision (CLOMR) has been approved by FEMA. A letter of map revision must be obtained upon completion of the proposed development. c. If subsection (5)a of this section is satisfied, all new construction and substantial improvements shall comply with all applicable flood hazard reduction provisions of this division. d. The placement of manufactured homes (mobile homes) is prohibited except in an existing manufactured home (mobile home) park or subdivision. A replacement manufactured home may be placed on a lot in an existing manufactured home park or subdivision provided the anchoring standards and the elevation standards are met. e. Permissible uses within floodways may include: general farming, pasture, outdoor plant nurseries, horticulture, forestry, wildlife sanctuary, game farm, and other similar agricultural, wildlife, and related uses. Also, lawns, gardens, play areas, picnic grounds, and hiking and horseback riding trails are acceptable uses, provided that they do not employ structures or fill. Substantial development of a permissible use may require a no-impact certification. The uses listed in this subsection are permissible only if and to the extent that they do not cause any increase in base flood elevations or changes to the floodway configuration. f. Map maintenance activities. The National Flood Insurance Program (NFIP) requires flood data to be reviewed and approved by FEMA. This ensures that flood maps, studies and other data identified in this ordinance accurately represent flooding conditions so appropriate floodplain management criteria are based on current data. (7) Requirement to submit new technical data. a. For all development proposals that impact floodway delineations or base flood elevations, the community shall ensure that technical or scientific data reflecting such changes be submitted to FEMA as soon as practicable, but no later than six months from the date such information becomes available. These development proposals include; but not limited to: 1. Floodway encroachments that increase or decrease base flood elevations or alter floodway boundaries; 2. Fill sites to be used for the placement of proposed structures where the applicant desires to remove the site from the special flood hazard area; 3. Alteration of watercourses that result in a relocation or elimination of the special flood hazard area, including the placement of culverts; and 4. Subdivision or large scale development proposals requiring the establishment of base flood elevations in accordance with this article. b. It is the responsibility of the applicant to have technical data, required in accordance with this ordinance, prepared in a format required for a conditional letter of map revision or letter of map revision, and submitted to FEMA. Submittal and processing fees for these map revisions shall also be the responsibility of the applicant. 1. The local floodplain administrator shall require a conditional letter of map revision prior to the issuance of a floodplain development permit for: 2. Proposed floodway encroachments that increase the base flood elevation; and 3. Proposed development which increases the base flood elevation by more than one foot in areas where FEMA has provided base flood elevations but no floodway. 4. Floodplain development permits issued by the local floodplain administrator shall be conditioned upon the applicant obtaining a Letter of Map Revision from FEMA for any development proposal subject to this article. 5. Right to submit new technical data. The floodplain administrator may request changes to any of the information shown on an effective map that does not impact floodplain or floodway delineations or base flood elevations, such as labeling or planimetric details. Such a submission shall include appropriate supporting documentation made in writing by the local jurisdiction and may be submitted at any time. (8) Accessory structures. A detached accessory structure or garage, the cost of which is greater than $3,000.00, must comply with the requirements as outlined in FEMA's Technical Bulletin 7-93 Wet Floodproofing Requirements or be elevated in accordance with this article or dry floodproofed in accordance with this article. a. If accessory structures of $3,000.00 or less are to be placed in the floodplain, the following criteria shall be met: 1. Accessory structures shall not be used for any uses other than the parking of vehicles and storage; 2. Accessory structures shall be designed to have low flood damage potential; 3. Accessory structures shall be constructed and placed on the building site so as to offer the minimum resistance to the flow of floodwaters; 4. Accessory structures shall be firmly anchored to prevent flotation, collapse and lateral movement of the structure; 5. Service facilities such as electrical and heating equipment shall be installed in accordance with this article; 6. Openings to relieve hydrostatic pressure during a flood shall be provided below base flood elevation in conformance with this article; and 7. Accessory structures shall be built with flood resistance materials in accordance with Technical Bulletin 2, Flood Damage-Resistant Materials Requirements, dated 8/08, and available from the Federal Emergency Management Agency. Class 4 and 5 materials, referenced therein, are acceptable flood-resistant materials. 8. Swimming pool utility equipment rooms. If the building cannot be built at or above the BFE, because of functionality of the equipment then a structure to house the utilities for the pool may be built below the BFE with the following provisions: 9. The utilities must be anchored to prevent flotation and shall be designed to prevent water from entering or accumulating within the components during conditions of the base flood. b. Elevators. 1. Install a float switch system or another system that provides the same level of safety necessary for all elevators where there is a potential for the elevator cab to descend below the BFE during a flood per FEMA's Technical Bulletin 4-93 Elevator Installation for Buildings Located in Special Flood Hazard Areas. 2. All equipment that may have to be installed below the BFE such as counter weight roller guides, compensation cable and pulleys, and oil buffers for traction elevators and the jack assembly for a hydraulic elevator must be constructed using flood-resistant materials where possible per FEMA's Technical Bulletin 4-93 Elevator Installation for Buildings Located in Special Flood Hazard Areas. c. Fill. 1. An applicant shall demonstrate that fill is the only alternative to raising the building to meet the residential and non-residential construction requirements of subsection 21-172(1) or (2), and that the amount of fill used will not affect the flood storage capacity or adversely affect adjacent properties. The following provisions shall apply to all fill placed in the special flood hazard area: 2. Fill may not be placed in the floodway unless it is in accordance with the requirements in this article. 3. Fill may not be placed in tidal or non-tidal wetlands without the required state and federal permits. 4. Fill must consist of soil and rock materials only. A registered professional geotechnical engineer may use dredged material as fill only upon certification of suitability. Landfills, rubble fills, dumps, and sanitary fills are not permitted in the floodplain. 5. Fill used to support structures must comply with ASTM Standard D-698, and its suitability to support structures certified by a registered, professional engineer. 6. Fill slopes shall be no greater than two horizontal to one vertical. Flatter slopes may be required where velocities may result in erosion. 7. The use of fill shall not increase flooding or cause drainage problems on neighboring properties. 8. Fill may not be used for structural support in the coastal high hazard areas. 9. Will meet the requirements of FEMA Technical Bulletin 10-01, Ensuring That Structures Built On Fill in or Near Special Flood Hazard Areas Are Reasonable Safe from Flooding.
(Code 1979, § 6-12052; Ord. No. 2015-046, 6-16-15; Ord. No. 2017-090, 12-5-17; Ord. No.2023-026, 3-7-23)
Ask a question about Columbia law
Corpus searches the Columbia sections it holds and shows the ones that match, with their citations. Free, no sign-in.
