§ 32-58 — General sewer use requirements
Code of Ordinances of the City of Abilene, Texas (Supp. No. 15: codified through Ordinance No. 85-2026, enacted September 24, 2026) · Abilene Code of Ordinances § 32-58
Corpus is an independent public-information project, not the official City of Abilene website. Stable reference: corpuslaw.us/code/63bc2fbe-196e-438e-b195-de9dc73cb244
Sec. 32-58. - General sewer use requirements.
(a) Prohibited discharge standards. (1) General prohibitions. No user shall introduce or cause to be introduced into the POTW any pollutant or wastewater which causes pass through or interference. These general prohibitions apply to all users of the POTW whether or not they are subject to categorical pretreatment standards or any other national, state, or local pretreatment standards or requirements. (2) Specific prohibitions. No user shall introduce or cause to be introduced into the POTW the following pollutants, substances, or wastewater: a. Pollutants which create a fire or explosive hazard in the POTW, including, but not limited to, wastestreams with a closed-cup flashpoint of less than one hundred forty (140) degrees F (sixty (60) degrees C) using the test methods specified in 40 CFR 261.21; b. Wastewater having a pH less than five (5.0) or more than eleven (11), or otherwise causing corrosive structural damage to the POTW or equipment; c. Solid or viscous substances in amounts which will cause obstruction of the flow in the POTW resulting in interference, but in no case solids greater than one-half inch in any dimension; d. Pollutants, including oxygen-demanding pollutants (BOD, etc.), released in a discharge at a flow rate and/or pollutant concentration which, either singly or by interaction with other pollutants, will cause interference with the POTW; e. Wastewater having a temperature which will inhibit biological activity in the treatment plant resulting in interference, but in no case wastewater which causes the temperature at the introduction into the treatment plant to exceed one hundred and four (104) degrees F (forty (40) degrees C); f. Petroleum oil, nonbiodegradable cutting oil, or products of mineral oil origin, in amounts that will cause interference or pass through; g. Pollutants which result in the presence of toxic gases, vapors, or fumes within the POTW in a quantity that may cause acute worker health and safety problems; h. Trucked or hauled pollutants, except at discharge points designated by the Director in accordance with subsection 32-59(d) of this article; i. Noxious or malodorous liquids, gases, solids, or other wastewater which, either singly or by interaction with other wastes, are sufficient to create a public nuisance or a hazard to life, or to prevent entry into the sewers for maintenance or repair; j. Wastewater which imparts color which cannot be removed by the treatment process, such as, but not limited to, dye wastes and vegetable tanning solutions, which consequently imparts color to the treatment plant's effluent, thereby violating the City's TPDES permit; k. Wastewater containing any radioactive wastes or isotopes except as specifically approved by the Director in compliance with applicable state or federal regulations; l. Stormwater, surface water, ground water, roof runoff, subsurface drainage, swimming pool drainage, condensate, deionized water, noncontact cooling water, and unpolluted wastewater, unless specifically authorized by the Director; m. Sludges, screenings, or other residues from the pretreatment of industrial wastes; n. Wastewater causing, alone or in conjunction with other sources, the treatment plant's effluent to fail a toxicity test; o. Detergents, surface-active agents, or other substances which may cause excessive foaming in the POTW. Pollutants, substances, or wastewater prohibited by this section shall not be processed or stored in such a manner that they could be discharged to the POTW. (b) Federal categorical pretreatment standards. The National Categorical Pretreatment Standards found at 40 CFR chapter I, subchapter N, parts 403.6 and 405—471 are hereby incorporated. (c) State pretreatment standards. State requirements and limitations on discharges shall apply in any case where they are more stringent than federal requirements and limitations or those in this article. (d) Local limits. (1) The following pollutant limits are established to protect against pass through and interference. No person shall discharge wastewater containing in excess of the following instantaneous maximum allowable discharge limits: 1.00 mg/L Arsenic 0.40 mg/L Cadmium 1.30 mg/L Chromium 4.50 mg/L Copper 5.10 mg/L Lead 0.014 mg/L Mercury 2.50 mg/L Nickel 0.71 mg/L Selenium 0.80 mg/L Silver 4.20 mg/L Zinc The above limits apply at the point where the wastewater is discharged to the POTW. All concentrations for metallic substances are for "total" metal unless indicated otherwise. The Director may impose mass limitations in addition to, or in place of, the concentration-based limitations above. (2) No user shall introduce or cause to be introduced into the POTW wastewater containing any of the following amounts or levels of pollutants or substances: a. True color which passes through the POTW greater than forty (40) color units. b. Free or emulsified animal or vegetable oil or grease (FOG) exceeding two hundred (200) mg/L instantaneous maximum. Exceedance of the instantaneous maximum limit is a violation of the City's industrial pretreatment program only if any of the conditions specified below are present. 1. Will solidify or become discernibly viscous at any temperature between thirty-two (32) degrees Fahrenheit and ninety (90) degrees Fahrenheit; 2. Deposit grease or oil in the sewer lines in such manner as to clog the sewers; 3. Overload the user/discharger's skimming and grease handling equipment; 4. Are not amenable to biological oxidation and will therefore pass to the receiving waters without being affected by normal sewage treatment processes; 5. Have deleterious effects on the treatment process due to the excessive quantities; or 6. Cause objectionable odors. c. Total petroleum hydrocarbons (TPH) exceeding one hundred sixty-seven (167) lbs. per day. (e) City's right of revision. The City reserves the right to establish, by ordinance or in wastewater discharge permits, more stringent standards or requirements on discharges to the POTW. (f) Special agreement. The City reserves the right to enter into special agreements with users setting out special terms under which they may discharge to the POTW. A user may request a net gross adjustment to a categorical standard in accordance with 40 CFR 403.15. A user also may request a variance from the categorical pretreatment standard from the approval authority. Such a request will be approved only if the user can prove that factors relating to its discharge are fundamentally different from the factors considered by EPA when establishing that categorical pretreatment standard. A user requesting a fundamentally different factor variance must comply with the procedural and substantive provisions in 40 CFR 403.13. (g) Dilution. No user shall ever increase the use of process water, or in any way attempt to dilute a discharge, as a partial or complete substitute for adequate treatment to achieve compliance with a discharge limitation unless expressly authorized by an applicable pretreatment standard or requirement. The Director may impose mass limitations on users who are using dilution to meet applicable pretreatment standards or requirements, or in other cases when the imposition of mass limitations is appropriate.
(Ord. No. 36-1992, pt. 1, 9-24-92; Ord. No. 36-2003, pt. 1(Exh. A), 9-25-03; Ord. No. 39-2020, pt. 1(Exh. A), 10-22-20)
Ask a question about Abilene law
Corpus searches the Abilene sections it holds and shows the ones that match, with their citations. Free, no sign-in.
