§ 8.11 — Street lights
Code of Ordinances of the City of Allen, Texas (Codified through Ordinance No. 4212-2-26, adopted February 10, 2026 (Supp. No. 23)) · Allen Land Development Code § 8.11
Corpus is an independent public-information project, not the official City of Allen website. Stable reference: corpuslaw.us/code/9e982339-6965-4740-b242-79f8ee835816
Sec. 8.11. - Street lights.
The city requires street lighting to improve the safety and usability of all roadways. The following requirements are to establish the minimum standards regarding the design and installation of street lighting, but should be considered flexible. Modifications to the standards will be considered by the director of engineering if the modifications incorporate new safety designs, achieve desired aesthetic treatment, or are shown to be more energy efficient. All new street light installations shall meet the approval of the director of engineering and may be reviewed by the Allen Police Department. 1. Thoroughfare street lights. This section applies to all streets identified on the City of Allen Thoroughfare Plan as arterials or divided collectors. Thoroughfare street light elements shall become the property of the City of Allen upon final acceptance of the subdivision or project. The elements (from the light sources to the meter) include all items necessary to provide such illumination. Thoroughfare street lighting shall conform to the following requirements: a. All thoroughfare lighting poles shall have the following attributes: i. Thirty-foot height. ii. Installation location shall be in the median. iii. Dual fixtures installed, if located in the median. Single fixtures are acceptable in situations that require parkway installation or the median width makes the installation of dual fixtures impractical. iv. Capable of withstanding a 100 mph wind, with 30 percent gust factor. v. Mounted on a cast-in-place pole-base, as illustrated in the Engineering Standard Details, using a 14-inch bolt pattern for the anchor bolts. Mounting bolts shall be a breakaway type bolt. vi. Powder-coated medium bronze, seven-inch × seven-inch, and straight (for shoebox fixtures). Galvanized finish, round, and tapered (for cobra-head fixtures). vii. Square, steel base cover, powder-coated or galvanized to match the finish of the pole. b. All thoroughfare fixtures shall have the following attributes: i. Light emitting diode (LED) lamps, 250 watt equivalent. LEDs shall be a color of 3000K. ii. The use of cut-off optics is required to achieve a fully shielded (as defined in articles of this Code) light source. This requirement shall not be modified. iii. Photometrics that minimize light pollution onto private property (at the ROW line) and provide an average intensity of one footcandle within the right-of-way. In the case of parkway installed lighting, forward-throw photometrics will be required. A photometric plan, signed and sealed by a licensed professional engineer, is required and shall be submitted to the engineering department for review. iv. For shoebox installation, the fixture shall be powder-coated medium bronze and shall be Trastar Duralight JXM-ST Shoebox or approved equivalent. v. In the case of cobra-head installation, finish shall be grey and shall be GE Evolve Series or equivalent. vi. Light spacing shall be determined by Texas Licensed Professional Engineer. c. Service and circuitry: i. Power to the street lighting system in the City of Allen can come from a variety of utility providers (TXU, CoServ, GCEC, etc.). Regardless of utility provider, the service line must be separated by the primary feed by an electric meter. The City of Allen will make application for service once a permit has been requested, an address assigned, and the meter pedestal has been installed. ii. Circuit voltage shall be 480V, to maximize the number of lights per circuit. Designer shall confirm with local utility provider for availability. iii. Main line conduit shall be located no closer than three feet behind the median curb. Placement in the center of the median should also be avoided, in the event landscaping and trees are installed. iv. Pull boxes shall be located at every change in conduit direction greater than 45 degrees and shall be spaced at even intervals with consideration given to pull distances for specified wire gage. All pull boxes shall be located behind the radius point of median noses. All pull-box lids shall read "CITY OF ALLEN LIGHTING." v. The meter pedestal may either be stand-alone or mounted to the controller cabinet for the street lighting system. Consult with utility company for height and mounting requirements for the meter socket. vi. All service transformers and wiring must be within the pole or underground. vii. The control panel and all secondary service connections shall be fully enclosed in a vandal-proof controller cabinet (i.e., no Kindorff racks, where the components are exposed to the elements, will be permitted, in consideration of aesthetics and security). The controller cabinet shall have the following attributes: (1) Illustrated on the construction drawings by a line diagram, signed and sealed by a licensed professional electrical engineer. (2) Utilize a master photocell controller and relay-switch override. (3) NEMA 3R enclosure, with drip edge and hinged door with lock. Lock shall match City of Allen standard key pattern. (4) Mounted on an appropriate reinforced, concrete pad. (5) If TXU or Oncor is the provider, the enclosure must include a Oncor or TXU-provided trans-socket. The trans-socket must remain intact when installed/integrated into the enclosure. (6) The controller cabinet must be powder-coated green unless otherwise approved by the director of engineering. 2. Residential street lights. This section applies to all streets identified on the City of Allen Thoroughfare Plan as undivided collectors or local streets. Residential streetlight elements shall become the property of the City of Allen upon final acceptance of the subdivision or project. The elements (from the light sources to the disconnect device) include all items necessary to provide such illumination. Residential street lighting shall conform to the following requirements: a. Street lights are required at all intersections, in cul-de-sacs, major street curves, and in other locations determined by the director of engineering. Developers shall furnish satisfactory easements for the installation of services to street lights, normally ten feet in width. b. Residential lighting shall utilize the "shoebox" style fixture. Homeowners' associations may enter into agreements with the City of Allen to install, maintain, and replace residential street lights that differ aesthetically from what is required in the section. c. All residential lighting poles shall have the following attributes (unless approved in writing by the director of engineering): i. Height and spacing are based on pavement widths and are prescribed below. ii. Single-fixture mounting. iii. Capable of withstanding a 100 mph wind, with 30 percent gust factor. iv. Mounted on a cast-in-place pole-base, as illustrated in Engineering Standard Detail, SD-P59, using a 14-inch bolt pattern for the anchor bolts. Mounting bolts shall be a breakaway type bolt. v. Powder-coated medium bronze, five-inch × five-inch, and straight (i.e. not tapered). vi. Square, steel base cover, powder-coated to match the finish of the pole. d. All residential fixtures shall have the following attributes (unless approved in writing by the director of engineering): i. Light emitting diode (LED) lamp intensity is based off pavement width as prescribed below. LEDs shall have a color of 3000K. ii. The use of cut-off optics is required to achieve a fully shielded (as defined in articles of this Code) light source. This requirement shall not be modified. iii. Forward-throw photometrics should be considered to reduce light pollution onto private lots or property. A photometric plan, signed and sealed by a licensed professional engineer, is required when the street lighting plan is submitted for engineering department review. iv. For shoebox installation, the fixture shall be powder-coated medium bronze and shall be Trastar Duralight JXM-ST Shoebox or approved equivalent. e. Service and circuitry: i. Power to the street lighting system will come from the electric utility provider for the subdivision. Regardless of utility provider, the service line should come from the nearest electric transformer and be isolated by a disconnect switch or in-line barrel fuse located at the base of the pole (in the hand-hole). Secondary service lines shall be contained within a ten-foot utility easement (UE) illustrated on the plat. All service lines shall be underground. The director of engineering may require that residential street lights be on metered circuit similar to the thoroughfare street lighting. ii. Circuit voltage shall be 120/240V. Designer shall confirm with local utility provider for availability. iii. A photocell is required at the top of the pole unless powered by a controller and will have a master photocell at the controller. f. Developer cost: All residential street lighting shall be installed at the sole expense of the developer. Developers shall pay a fee to the City of Allen Engineering Department, which is estimated to be equal to the first two years (24 months) power consumption cost. The amount of the fee to be paid shall be determined by the following formula: FA = 24 × M × F Where: FA = Fee amount. M = Monthly charge per fixture (as determined by the director of engineering). F = Number of light fixtures. Residential Street Lighting Requirement Table Street Type, Paving Width (feet) | Light Source | Nominal Lamp Size (LED) (Watts) | Mounting Height (feet) | Max Spacing (feet) | Minimum Spacing (feet) <32 | LED | 100 Equivalent | 20 | 250 | 125 32 to 43 | LED | 150 Equivalent | 20 | 250 | 150 44 Undivided < | LED | 150 Equivalent | 30 | 350 | 150
(Ord. No. 2593-2-07, § 1(Exh. A), 2-13-2007; Ord. No. 3125-11-12, § 8, 11-27-2012; Ord. No. 3614-9-18, § 9, 9-25-2018; Ord. No. 3846-8-21, § 4.C, 8-10-2021)
Ask a question about Allen law
Corpus searches the Allen sections it holds and shows the ones that match, with their citations. Free, no sign-in.