§ 22.02.053: Definitions.
The following definitions shall apply to this division: Air gap. The unobstructed vertical distance through free atmosphere between the lowest opening from any pipe or faucet conveying water or waste to a tank, plumbing fixture, receptor, or other assembly and the flood level rim of the receptacle. These vertical physical separations must be at least twice the diameter of the water supply outlet, never less than one (1) inch (25 mm). Auxiliary supply. Any water supply on or available to the premises other than the city’s approved public water supply. These auxiliary waters may include water from another purveyor’s public potable water supply or any natural sources, such as, but not limited to, a well, spring, river, stream, used waters, or industrial fluids. These waters constitute an unacceptable water source over which the city does not have sanitary control. Backflow. The undesirable reversal of flow in a potable water distribution system as a result of a cross-connection. Backflow prevention device or assembly. Any mechanical or physical means to prevent backflow into the potable water system, including reduced pressure backflow assemblies, double check valve assemblies, atmospheric vacuum breakers, pressure vacuum breaker assemblies, or air gap. All backflow prevention assemblies must be approved by the city and shall have been manufactured in full conformance with the standards established by the American Water Works Association and have met completely the laboratory and field performance specifications of the Foundation for Cross-Connection Control and Hydraulic Research of the University of Southern California established by “Specification of Backflow Prevention Assemblies” of the most current issue of the Manual of Cross-Connection Control. City or the city. The City of Beaumont or its authorized representative, which, for the purposes of implementation and enforcement of the backflow prevention program, shall normally mean representatives of water utilities. Commission or TCEQ. The state commission on environmental quality, the regulatory agency of the state. Cross-connection. Any actual or potential connection or structural arrangement between a potable water supply system and any plumbing fixture or any tank, receptacle equipment or device, through which it may be possible for any nonpotable, used, unclean, polluted and/or contaminated water, or other contaminant, to enter into any part of such potable water system under any condition or set of conditions. Double check valve assembly. A backflow prevention assembly which consists of two internally loaded check valves, either spring loaded or internally weighted, installed as a unit between two tightly closing resilient-seated shutoff valves and fittings with properly located resilient-seated test cocks. Person. Any individual, partnership, associations, corporations, firms, clubs, trustees, receivers, and bodies politic and corporate. Plumbing code. The city’s plumbing code as adopted under section 24.02.151 of the Code of Ordinances of the city. Potable water supply. Any water supply intended or used for human consumption or other domestic use. Public water system or supply. Any public or privately owned water system which supplies water for public domestic use. The system will include all services, reservoirs, facilities, and any equipment used in the process of producing, treating, storing, or conveying water for public consumption. For the purposes of this division, this shall normally mean the public water supply maintained by the city. Premises. Any piece of property to which water is provided, including all improvements, mobile structures, and structures located on it. Recognized backflow prevention assembly tester. An individual meeting the requirements of the most recent revisions to title 30, Texas Administrative Code section 290.44(h)(4), and holding a current endorsement from the state commission on environmental quality or its designated agent, for the type of assembly being tested. Reduced pressure principle assembly. A backflow prevention assembly consisting of two independently acting approved check valves together with a hydraulically operating, mechanically independent pressure differential relief valve located between the check valves and below the first check valve. These units are located between two tightly closing resilient-seated shutoff valves as an assembly and equipped with properly located resilient-seated test cocks. Water utilities director. The person in charge of the city water utilities department or his/her designated representative.
( Ordinance 01-032 , sec. 1, adopted 3/27/01 ; 1978 Code, sec. 28-57(c) ; Ordinance 08-040 , sec. 28, adopted 5/13/08 )
Ask a question about Beaumont law
Corpus searches the Beaumont sections it holds and shows the ones that match, with their citations. Free, no sign-in.