§ 22.02.062: Installation requirements.
Backflow prevention assemblies shall be installed in accordance with the following requirements, to ensure their proper operation and accessibility: (1) Backflow prevention assemblies shall be installed in accordance with the city’s plumbing code and the manufacturer’s instructions. All backflow prevention assemblies installed in accordance with this division shall be tested upon installation by a recognized backflow prevention assembly tester. The test report shall be sent to the water utilities department within ten (10) days of the installation. The assembly installer shall obtain the required plumbing permits prior to installation as required by the city’s plumbing code. (2) No part of a reduced pressure principle backflow prevention assembly shall be located in water or installed in a pit or other location subject to flooding. If a double check valve assembly is installed in a vault, brass plugs shall be maintained in the test ports at all times and adequate drainage shall be provided. (3) When a backflow prevention assembly is installed to serve an entire establishment, the assembly shall be installed at the service connection of the water supply, before any branch in the line, and on private property located just inside the boundary of the city’s right-of-way. The water utilities director may specify additional areas for installation of assemblies if needed. (4) Backflow prevention assemblies shall be protected from freezing and other severe weather conditions. (5) All vertical installations shall be approved in writing by the water utilities director prior to installation. (6) Backflow prevention assemblies shall be readily accessible with adequate room for maintenance and testing. Assemblies two (2) inches and smaller shall have at least six-inch clearance on all sides of the assembly. All assemblies larger than two (2) inches shall have a minimum clearance of twelve (12) inches on the back side, twenty-four (24) inches on the test cock side, twelve (12) inches below the assembly, and thirty-six (36) inches above the assembly. “Y” pattern double check valve assemblies shall be installed so that the checks are horizontal and the test cocks face upward. (7) If an assembly is installed five (5) feet or higher above the ground or floor, it shall be equipped with a suitable platform for use by testing or maintenance personnel. This installation shall meet all applicable Occupational Safety and Health Administration (OSHA) regulations and occupational safety and health laws of the state. (8) Bypass lines are prohibited. Pipe fittings which could be used for connecting a bypass line shall not be installed.
( Ordinance 01-032 , sec. 1, adopted 3/27/01 ; 1978 Code, sec. 28-57(l) ; Ordinance 08-040 , sec. 28, adopted 5/13/08 )
Ask a question about Beaumont law
Corpus searches the Beaumont sections it holds and shows the ones that match, with their citations. Free, no sign-in.