§ 22.02.060: Abatement by city.

(a) The city shall conduct a plumbing inspection or customer service inspection on any residential or commercial establishment served by the city’s public water supply prior to providing continuous water service to all new construction, on any existing service when the water utilities director has reason to believe that cross-connections or other contaminant hazards exist, or after any material improvement, correction, or addition to the customer’s private distribution facilities. The purpose of the inspection is to determine compliance with this division and applicable portions of the city’s plumbing code relating to cross-connection control and unsafe plumbing practices. Upon determination by the city that the residential or commercial establishment falls under the provisions of this division and requires a backflow prevention assembly, the water utilities director shall issue a notice to abate the condition or order the establishment to install the proper backflow prevention assembly(ies) commensurate with the degree of hazard. A copy of the notice which is issued or caused to be issued by the water utilities director shall be forwarded to the chief plumbing inspector of the city. (b) An approved backflow prevention assembly shall be installed on each service line or point of delivery to a consumer’s water system whenever the following conditions exist: (1) In the case of premises having an auxiliary water supply which is not or may not be of safe bacteriological or chemical quality and which is not acceptable as an additional source by the TCEQ or the city, the public water system shall be protected against backflow from the premises by installing an approved backflow prevention assembly in the service line commensurate with the degree of hazard. (2) In the case of premises on which any industrial fluids or any other objectionable substance is handled in such a fashion as to create an actual or potential hazard to the public water system, the public system shall be protected against backflow from the premises by installing an approved backflow prevention assembly in the service line commensurate with the degree of hazard. This shall include the handling of process waters and waters originating from the city’s public water system which have been subject to deterioration in quality. (3) In the case of premises having (i) internal cross-connections that cannot be permanently corrected or protected against, or (ii) intricate plumbing and piping arrangements or where entry to all portions of the premises is not readily accessible for inspection purposes, making it impracticable or impossible to ascertain whether or not dangerous cross-connections exist, the city’s public water system shall be protected against backflow from the premises by installing an approved backflow prevention assembly in each service line. (c) Using the city’s plumbing code, TCEQ regulations and guidelines, and American Water Works Association (AWWA) recommendations, the water utilities director shall designate the type of backflow prevention assembly required for each type of establishment or hazard. In the case of conflict between these references, the more stringent standard shall apply. (d) Any backflow prevention assembly required by this division shall be of a model and size approved by the water utilities director.

( Ordinance 01-032 , sec. 1, adopted 3/27/01 ; 1978 Code, sec. 28-57(j) ; Ordinance 08-040 , sec. 28, adopted 5/13/08 )

Ask a question about Beaumont law

Corpus searches the Beaumont sections it holds and shows the ones that match, with their citations. Free, no sign-in.