For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 102-703 — Customer service inspections

Code of Ordinances, City of Brownsville, Texas (Supp. No. 26: codified through Ordinance No. 2026-1797, enacted January 20, 2026) · Brownsville City Code § 102-703

Corpus is an independent public-information project, not the official City of Brownsville website. Stable reference: corpuslaw.us/code/b13eddca-ec3b-4a29-b83c-664b0bfb3f09

Sec. 102-703. - Customer service inspections.

(a) The customer shall allow his property to be inspected by the retail public utility providing service to the customer for possible cross-connections and other potential contamination hazards. These inspections shall be conducted by a TCEQ licensed customer service inspector or an individual with the credentials described under section 102-703(c) below prior to initiating new water service; when there is reason to believe that cross-connections or other potential contamination hazards exist; or after any major changes to the private water distribution facilities. The inspections shall be conducted during normal business hours. (b) A customer service inspection shall be completed prior to providing continuous water service to all new construction, on any existing service when the retail public utility serving the customer has reason to believe that cross-connections or other contaminant hazards exist, or after any material improvement, correction, or addition to the private water distribution facilities. A customer service inspection shall be performed every ten years thereafter. (c) Only individuals with the following credentials shall be recognized as capable of conducting a customer service inspection: (1) Plumbing inspectors and water supply protection specialists that have been licensed by the Texas State Board of Plumbing Examiners. (2) Customer service inspectors that have been licensed by the TCEQ. (d) Commercial and residential customers that have a private water supply for a lawn irrigation system shall have an inspected and approved backflow prevention assembly at the service connection. The backflow prevention assembly must be maintained and tested in accordance with the 290 Rules. In addition, a customer that utilizes Resaca, well water, or auxiliary water for lawn irrigation systems shall register that system with the Brownsville Public Utilities Board Cross Connection Control Department. The Brownsville Public Utilities Board may discontinue water service to any customer who fails to register as required by this subsection after the Brownsville Public Utilities Board provides the customer notice and a reasonable opportunity to comply. (e) The customer service inspection must certify that: (1) No direct connection between the potable water retailer water supply and a potential source of contamination including any auxiliary sources of water is permitted. Potential sources of contamination shall be isolated from the potable water retailer by a properly installed air gap or an appropriate backflow prevention assembly. (2) No cross-connection between the potable water retailer and a private water source including any auxiliary sources of water exists. Where an actual properly installed air gap is not maintained between the potable water retailer and a private water supply, an approved reduced pressure-zone backflow prevention assembly is properly installed and a service agreement exists for annual inspection and testing by a TCEQ licensed backflow prevention assembly tester. (3) No connection exists which allows water to be returned to the public drinking water supply. (4) No pipe or pipe fitting which contains more than eight percent lead may be used in private water distribution facilities installed on or after July 1, 1988 and prior to January 4, 2014. Plumbing installed after January 4, 2014 that bears the expected label indicating less than 0.25% lead (or the most current TCEQ-approved value for lead concentrations) may be used for the installation or repair of plumbing at any connection that provides water for human use. (5) No solder or flux which contains more than 0.2% lead (or the most current TCEQ-approved value for lead concentrations) can be used for the installation or repair of plumbing at any connection that provides water for human use. A minimum of one lead test shall be performed for each inspection.

(Ord. No. 2018-983-DD, pt. 1, 12-4-2018)

Ask a question about Brownsville law

Corpus searches the Brownsville sections it holds and shows the ones that match, with their citations. Free, no sign-in.