For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 3.4.11 — Preliminary Utility Plan

Code of Ordinances, City of Brownsville, Texas (Supp. No. 26: codified through Ordinance No. 2026-1797, enacted January 20, 2026) · Brownsville City Code § 3.4.11

Corpus is an independent public-information project, not the official City of Brownsville website. Stable reference: corpuslaw.us/code/aa51d091-9c9f-403c-9880-45a72593dd5d

3.4.11 - Preliminary Utility Plan.

A. Applicability. 1. A preliminary utility plan shall detail both 3.4.9 Water Utility and 3.4.10 Wastewater Utility requirements and may be required as part the following plat applications in which the modification or extension of utilities is required for the proposed development: a. Preliminary Plat (refer to 3.2.1); b. Final Plat (refer to 3.2.2); c. Replat (refer to 3.2.4) 2. Preliminary utility plans shall comply with the criteria contained in the City's standard applications forms and checklists. 3. Preliminary utility plans shall be subject to the development review process in Figure 2.3-5 Development Review Process for Subdivision Related Applications required for plat and development applications. B. Plan criteria. 1. Concurrent with the submission of a Preliminary Plat (refer to 3.2.1), Final Plat (refer to 3.2.2) or any other plan in which the modification of public utilities is required, the developer shall submit a map or plan showing the location and size of water utility and wastewater utility mains, which will be required to provide adequate service to the lots specified in the proposed plat. 2. Preliminary utility plans shall show existing and proposed fire hydrant systems to show adequate fire protection as required in the UDC and the City's fire code. C. Coordination with other utility providers. 1. When the subdivision is in an area served by a utility provider other than the City, the developer is still required to provide a water system analysis, indicating adequate water supply and water quality for review by the City Engineer. 2. When a subdivision is in an area served by a utility provider other than the City, the developer must provide a letter from the utility provider stating that facilities exist in the area to provide adequate domestic service and fire protection. 3. If the City has reason to believe that there may be water supply or pressure concerns the City may require, a water system analysis, indicating adequate water supply and water quality. 4. A plat will not be approved until a letter has been provided from the utility provider stating that they have accepted the plans for construction.

Ask a question about Brownsville law

Corpus searches the Brownsville sections it holds and shows the ones that match, with their citations. Free, no sign-in.