§ 3.4.9 — Water Utility
Code of Ordinances, City of Brownsville, Texas (Supp. No. 26: codified through Ordinance No. 2026-1797, enacted January 20, 2026) · Brownsville City Code § 3.4.9
Corpus is an independent public-information project, not the official City of Brownsville website. Stable reference: corpuslaw.us/code/f1501a12-85ba-4289-b308-cb2a9da7dd61
3.4.9 - Water Utility.
A. General provision. 1. All subdivisions in the city limits and the ETJ shall provide an adequate water distribution system and connect to a public water system in conformance with the standards of the public water service provider. a. The city limits and ETJ are serviced by various public water providers and it is the responsibility of the applicant to determine the public water provider that services their property. 2. Any new water main(s) must designed and installed by the developer's engineer prior to public water provider accepting such water facility or facilities for maintenance. a. The developer's engineer will coordinate with both the City Engineer and public water provider to receive construction plan approval for the construction or modification of water facilities. 3. The public water provider can prohibit a connection to an existing or proposed water system when they determine that a connection will exceed capacity or overload the water system to serve the anticipated water demand of the proposed development. 4. In the absence of specific standards, all water supply, distribution, pumping, and storage improvements shall be designed in accordance with the most current standards of the American Water Works Association and the most current criteria included in the Texas Administrative Code (Title 30, Part 1, Chapter 290), Public Drinking Water. 5. The public water provider shall make the final determination of the adequacy of the proposed system. 6. The public water provider in coordination with the City Engineer may require the phasing of development or improvements to maintain adequate water capacity. 7. All water mains shall be constructed within the street right-of-way and easements will be dedicated to the public water provider. a. The public water provider shall determine placement and width of water easements. B. Water line extension to subdivision perimeters. All water lines installed within a subdivision must extend to the border and perimeter of the subdivision to allow for future water extensions to adjacent properties, regardless of whether such extensions are required for service within the subdivision. C. Fire hydrants. 1. Fire hydrants shall be placed on block corners or near the center of the block to place all or every lot within a radius of five hundred (500) feet in residential areas, but under no circumstances shall a hose-lay for more than five hundred (500) feet be made from the fire hydrant to cover all of every lot within the Subdivision or tract under development. 2. Fire hydrants shall be located in commercial and industrial areas so that all of every lot shall be within a radius of three hundred (300) feet, but under no circumstances shall a hose-lay of more than three hundred (300) feet be made in order to adequately afford fire protection to the building or buildings. 3. A fire hydrant shall be placed at the entrance or at the end of all cul-de-sacs subject to review of the fire marshal in coordination with the public water service provider. 4. Hydrants must provide enough pressure for fire protection in accordance with the City's adopted fire codes subject to review and approval of the fire marshal in coordination with the public water service provider.
Ask a question about Brownsville law
Corpus searches the Brownsville sections it holds and shows the ones that match, with their citations. Free, no sign-in.
